The vista system: a new bipolar resection device for endourological procedures: comparison with conventional resectoscope

Objective: - Conventional transurethral resection of the prostate (TURP) uses a monopolar electrocautery system in which the current passes from the active electrode through the patient's body towards the return plate and may cause distant negative effects. In this study a new developed resecti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wendt-Nordahl, Gunnar (VerfasserIn) , Häcker, Axel (VerfasserIn) , Reich, Oliver (VerfasserIn) , Djavan, Bob (VerfasserIn) , Alken, Peter (VerfasserIn) , Michel, Maurice Stephan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 12 August 2004
In: European urology
Year: 2004, Jahrgang: 46, Heft: 5, Pages: 586-590
ISSN:1873-7560
DOI:10.1016/j.eururo.2004.07.018
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.eururo.2004.07.018
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0302283804003720
Volltext
Verfasserangaben:Gunnar Wendt-Nordahl, Axel Häcker, Oliver Reich, Bob Djavan, Peter Alken, Maurice Stephan Michel

MARC

LEADER 00000caa a2200000 c 4500
001 1794927204
003 DE-627
005 20220820142711.0
007 cr uuu---uuuuu
008 220307s2004 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.eururo.2004.07.018  |2 doi 
035 |a (DE-627)1794927204 
035 |a (DE-599)KXP1794927204 
035 |a (OCoLC)1341445523 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wendt-Nordahl, Gunnar  |d 1975-  |e VerfasserIn  |0 (DE-588)12482272X  |0 (DE-627)366751255  |0 (DE-576)294520422  |4 aut 
245 1 4 |a The vista system  |b a new bipolar resection device for endourological procedures: comparison with conventional resectoscope  |c Gunnar Wendt-Nordahl, Axel Häcker, Oliver Reich, Bob Djavan, Peter Alken, Maurice Stephan Michel 
264 1 |c 12 August 2004 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 07.03.2022 
520 |a Objective: - Conventional transurethral resection of the prostate (TURP) uses a monopolar electrocautery system in which the current passes from the active electrode through the patient's body towards the return plate and may cause distant negative effects. In this study a new developed resection device, the Vista system, using a bipolar electrocautery system and 0.9% sodium chloride solution for irrigation, was evaluated in an ex-vivo model. - Methods: - The modified model of the isolated blood perfused kidney was used to determine cutting qualities, ablation rate, blood loss and coagulation depth of the bipolar resectoscope. After ablating the renal tissue of a perfused kidney in a surface area, blood loss was semiquantitatively determined. Afterwards samples were taken and processed for histological evaluation of the coagulation depth. We compared the new bipolar resection device against a conventional monopolar resectoscope. - Results: - We found good cutting qualities of the bipolar resectoscope although it is more difficult to start a cut. The ablation rate is determined by the width of the electrode and is similar to the standard device (30cm2/min). The bleeding is reduced with increasing output powers (26.13 ± 6.15g/min (level 5); 20.49 ± 5,47g/min (level 6); 13.16 ± 5,47g/min (level 7); 10.43 ± 4.76g/min (level 8) and lower compared to a conventional monopolar resectoscope (17.08 ± 4.47g/min). The coagulation depth increases with higher output powers but is reduced compared to the standard device (118 ± 22μm (level 5); 121 ± 23μm (level 6); 141 ± 62μm (level 7); 163 ± 30μm (level 8) versus 287 ± 57 (monopolar resectoscope)). - Conclusion: - Our results with the bipolar resection device for TURP suggest that it may offer an alternative to conventional TURP. As active and the return electrode are placed on the resectoscope, high current densities are achieved locally and complications caused by distant negative effects of the current are theoretically reduced in vivo. Furthermore the risk of TUR syndrome is theoretically eliminated by using physiological sodium chloride solution for irrigation. To prove the clinical significance of our ex-vivo findings, clinical studies including large numbers of patients have to be performed. 
650 4 |a Benign prostatic enlargement 
650 4 |a Bipolar resectoscope 
650 4 |a Bleeding 
650 4 |a TURP 
700 1 |a Häcker, Axel  |d 1971-  |e VerfasserIn  |0 (DE-588)121732177  |0 (DE-627)705632865  |0 (DE-576)292855923  |4 aut 
700 1 |a Reich, Oliver  |e VerfasserIn  |4 aut 
700 1 |a Djavan, Bob  |e VerfasserIn  |4 aut 
700 1 |a Alken, Peter  |d 1942-  |e VerfasserIn  |0 (DE-588)1036718352  |0 (DE-627)751026972  |0 (DE-576)385351941  |4 aut 
700 1 |a Michel, Maurice Stephan  |d 1970-  |e VerfasserIn  |0 (DE-588)121842568  |0 (DE-627)705674134  |0 (DE-576)29291363X  |4 aut 
773 0 8 |i Enthalten in  |t European urology  |d Amsterdam [u.a.] : Elsevier Science, 1976  |g 46(2004), 5, Seite 586-590  |h Online-Ressource  |w (DE-627)300191596  |w (DE-600)1482253-2  |w (DE-576)099718103  |x 1873-7560  |7 nnas  |a The vista system a new bipolar resection device for endourological procedures: comparison with conventional resectoscope 
773 1 8 |g volume:46  |g year:2004  |g number:5  |g pages:586-590  |g extent:5  |a The vista system a new bipolar resection device for endourological procedures: comparison with conventional resectoscope 
856 4 0 |u https://doi.org/10.1016/j.eururo.2004.07.018  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0302283804003720  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220307 
993 |a Article 
994 |a 2004 
998 |g 121842568  |a Michel, Maurice Stephan  |m 121842568:Michel, Maurice Stephan  |d 60000  |d 63100  |d 60000  |e 60000PM121842568  |e 63100PM121842568  |e 60000PM121842568  |k 0/60000/  |k 1/60000/63100/  |k 0/60000/  |p 6  |y j 
998 |g 1036718352  |a Alken, Peter  |m 1036718352:Alken, Peter  |d 60000  |d 63100  |d 60000  |e 60000PA1036718352  |e 63100PA1036718352  |e 60000PA1036718352  |k 0/60000/  |k 1/60000/63100/  |k 0/60000/  |p 5 
998 |g 121732177  |a Häcker, Axel  |m 121732177:Häcker, Axel  |d 60000  |d 63100  |e 60000PH121732177  |e 63100PH121732177  |k 0/60000/  |k 1/60000/63100/  |p 2 
998 |g 12482272X  |a Wendt-Nordahl, Gunnar  |m 12482272X:Wendt-Nordahl, Gunnar  |d 60000  |d 63100  |e 60000PW12482272X  |e 63100PW12482272X  |k 0/60000/  |k 1/60000/63100/  |p 1  |x j 
999 |a KXP-PPN1794927204  |e 4080913281 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"5 S."}],"title":[{"subtitle":"a new bipolar resection device for endourological procedures: comparison with conventional resectoscope","title":"The vista system","title_sort":"vista system"}],"language":["eng"],"note":["Gesehen am 07.03.2022"],"name":{"displayForm":["Gunnar Wendt-Nordahl, Axel Häcker, Oliver Reich, Bob Djavan, Peter Alken, Maurice Stephan Michel"]},"person":[{"given":"Gunnar","family":"Wendt-Nordahl","display":"Wendt-Nordahl, Gunnar","role":"aut"},{"given":"Axel","family":"Häcker","display":"Häcker, Axel","role":"aut"},{"role":"aut","display":"Reich, Oliver","family":"Reich","given":"Oliver"},{"role":"aut","family":"Djavan","display":"Djavan, Bob","given":"Bob"},{"given":"Peter","role":"aut","family":"Alken","display":"Alken, Peter"},{"given":"Maurice Stephan","role":"aut","family":"Michel","display":"Michel, Maurice Stephan"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"300191596","disp":"The vista system a new bipolar resection device for endourological procedures: comparison with conventional resectoscopeEuropean urology","part":{"volume":"46","pages":"586-590","text":"46(2004), 5, Seite 586-590","year":"2004","extent":"5","issue":"5"},"pubHistory":["Nachgewiesen 2.1976 -"],"origin":[{"publisher":"Elsevier Science ; Karger","dateIssuedDisp":"1976-","dateIssuedKey":"1976","publisherPlace":"Amsterdam [u.a.] ; Basel"}],"id":{"issn":["1873-7560","1421-993X"],"zdb":["1482253-2"],"eki":["300191596"]},"note":["Ungezählte Beil. bis 40.2001: Supplement"],"language":["eng"],"title":[{"title":"European urology","subtitle":"official organ of the European Association of Urology, the European Organization for Research and Treatment of Cancer - Genito-Urinary Group, the European Society for Urological Oncology and Endocrinology","title_sort":"European urology"}],"physDesc":[{"extent":"Online-Ressource"}]}],"origin":[{"dateIssuedDisp":"12 August 2004","dateIssuedKey":"2004"}],"id":{"eki":["1794927204"],"doi":["10.1016/j.eururo.2004.07.018"]},"recId":"1794927204"} 
SRT |a WENDTNORDAVISTASYSTE1220