Objectives - To investigate, in an experimental study, the efficacy of a different stimulation signal in a porcine model to suppress formalin-induced unstable detrusor contractions. The current mode of stimulation in peripheral nerve evaluation tests and sacral neuromodulation is based on rectangula...

Full description

Saved in:
Bibliographic Details
Main Authors: Braun, Peter-Martin (Author) , Seif, Christoph (Author) , Bross, Stephan (Author) , Martínez y Portillo, Francisco-José (Author) , Alken, Peter (Author) , Jünemann, Klaus-Peter (Author)
Format: Article (Journal)
Language:English
Published: 25 March 2003
In: Urology
Year: 2003, Volume: 61, Issue: 4, Pages: 839-844
ISSN:1527-9995
DOI:10.1016/S0090-4295(02)02403-2
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/S0090-4295(02)02403-2
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0090429502024032
Get full text
Author Notes:P.M. Braun, C. Seif, S. Bross, F.J. Martinez Portillo, P. Alken, and K.P. Jünemann

MARC

LEADER 00000caa a2200000 c 4500
001 1795007621
003 DE-627
005 20220820143216.0
007 cr uuu---uuuuu
008 220308s2003 xx |||||o 00| ||eng c
024 7 |a 10.1016/S0090-4295(02)02403-2  |2 doi 
035 |a (DE-627)1795007621 
035 |a (DE-599)KXP1795007621 
035 |a (OCoLC)1341445906 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Braun, Peter-Martin  |e VerfasserIn  |0 (DE-588)140953582  |0 (DE-627)623005387  |0 (DE-576)32151632X  |4 aut 
245 1 0 |a Stimulation signal modification in a porcine model for suppression of unstable detrusor contractions  |c P.M. Braun, C. Seif, S. Bross, F.J. Martinez Portillo, P. Alken, and K.P. Jünemann 
264 1 |c 25 March 2003 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.03.2022 
520 |a Objectives - To investigate, in an experimental study, the efficacy of a different stimulation signal in a porcine model to suppress formalin-induced unstable detrusor contractions. The current mode of stimulation in peripheral nerve evaluation tests and sacral neuromodulation is based on rectangular signal shapes. Published reports, however, have revealed that up to 80% of patients do not respond to peripheral nerve evaluation stimulation. - Methods - After placement of electrodes at S3 in 12 anesthetized Göttinger minipigs, unstable contractions were induced by intravesical instillation of formalin. Ten-minute stimulation phases with a quasi-trapezoidal signal and a rectangular signal followed. An interval of 30 minutes elapsed between the two series of stimulations. The pressure values were registered on a urodynamic unit and evaluated as contractions and amplitudes per minute. Six minipigs were treated in the same way but were not stimulated and served as the control group. - Results - After formalin instillation, the average number of involuntary detrusor contractions was 3.5/min (± 0.8) and the sum of amplitudes was 7.2/min (± 1.1). Subsequent NaCl instillation and quasi-trapezoidal stimulation reduced the contractions to 0.3/min (± 0.3) and the sum of amplitudes to 0.8/min (± 0.4). A contraction rate of 1.1/min (± 0.1) and a sum of amplitudes of 5.1/min (± 2.4) were recorded under stimulation with a rectangular signal. In the control group, no significant reduction was recorded. - Conclusions - The acquired data demonstrate that quasi-trapezoidal stimulation suppresses unstable detrusor contractions in the minipig more effectively than does conventional rectangular stimulation as presently applied in sacral neuromodulation. 
700 1 |a Seif, Christoph  |d 1971-  |e VerfasserIn  |0 (DE-588)12332775X  |0 (DE-627)08248760X  |0 (DE-576)293657637  |4 aut 
700 1 |a Bross, Stephan  |e VerfasserIn  |0 (DE-588)1076916902  |0 (DE-627)835460347  |0 (DE-576)18722837X  |4 aut 
700 1 |a Martínez y Portillo, Francisco-José  |d 1967-  |e VerfasserIn  |0 (DE-588)118149032  |0 (DE-627)07927224X  |0 (DE-576)291740065  |4 aut 
700 1 |a Alken, Peter  |d 1942-  |e VerfasserIn  |0 (DE-588)1036718352  |0 (DE-627)751026972  |0 (DE-576)385351941  |4 aut 
700 1 |a Jünemann, Klaus-Peter  |d 1956-2023  |e VerfasserIn  |0 (DE-588)141256613  |0 (DE-627)625869982  |0 (DE-576)323019374  |4 aut 
773 0 8 |i Enthalten in  |t Urology  |d Amsterdam [u.a.] : Elsevier Science, 1973  |g 61(2003), 4, Seite 839-844  |h Online-Ressource  |w (DE-627)320491064  |w (DE-600)2011025-X  |w (DE-576)121191044  |x 1527-9995  |7 nnas  |a Stimulation signal modification in a porcine model for suppression of unstable detrusor contractions 
773 1 8 |g volume:61  |g year:2003  |g number:4  |g pages:839-844  |g extent:6  |a Stimulation signal modification in a porcine model for suppression of unstable detrusor contractions 
856 4 0 |u https://doi.org/10.1016/S0090-4295(02)02403-2  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0090429502024032  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220308 
993 |a Article 
994 |a 2003 
998 |g 141256613  |a Jünemann, Klaus-Peter  |m 141256613:Jünemann, Klaus-Peter  |p 6  |y j 
998 |g 1036718352  |a Alken, Peter  |m 1036718352:Alken, Peter  |d 60000  |d 63100  |d 60000  |e 60000PA1036718352  |e 63100PA1036718352  |e 60000PA1036718352  |k 0/60000/  |k 1/60000/63100/  |k 0/60000/  |p 5 
998 |g 1076916902  |a Bross, Stephan  |m 1076916902:Bross, Stephan  |d 60000  |d 63100  |e 60000PB1076916902  |e 63100PB1076916902  |k 0/60000/  |k 1/60000/63100/  |p 3 
998 |g 12332775X  |a Seif, Christoph  |m 12332775X:Seif, Christoph  |d 60000  |d 61800  |e 60000PS12332775X  |e 61800PS12332775X  |k 0/60000/  |k 1/60000/61800/  |p 2 
999 |a KXP-PPN1795007621  |e 4082863192 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 08.03.2022"],"person":[{"roleDisplay":"VerfasserIn","family":"Braun","display":"Braun, Peter-Martin","role":"aut","given":"Peter-Martin"},{"given":"Christoph","role":"aut","roleDisplay":"VerfasserIn","family":"Seif","display":"Seif, Christoph"},{"given":"Stephan","role":"aut","roleDisplay":"VerfasserIn","display":"Bross, Stephan","family":"Bross"},{"family":"Martínez y Portillo","display":"Martínez y Portillo, Francisco-José","roleDisplay":"VerfasserIn","role":"aut","given":"Francisco-José"},{"family":"Alken","display":"Alken, Peter","roleDisplay":"VerfasserIn","role":"aut","given":"Peter"},{"display":"Jünemann, Klaus-Peter","family":"Jünemann","roleDisplay":"VerfasserIn","role":"aut","given":"Klaus-Peter"}],"title":[{"title":"Stimulation signal modification in a porcine model for suppression of unstable detrusor contractions","title_sort":"Stimulation signal modification in a porcine model for suppression of unstable detrusor contractions"}],"recId":"1795007621","id":{"doi":["10.1016/S0090-4295(02)02403-2"],"eki":["1795007621"]},"language":["eng"],"physDesc":[{"extent":"6 S."}],"name":{"displayForm":["P.M. Braun, C. Seif, S. Bross, F.J. Martinez Portillo, P. Alken, and K.P. Jünemann"]},"relHost":[{"id":{"issn":["1527-9995"],"zdb":["2011025-X"],"eki":["320491064"]},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedKey":"1973","publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"1973-","publisher":"Elsevier Science"}],"recId":"320491064","pubHistory":["1.1973 -"],"disp":"Stimulation signal modification in a porcine model for suppression of unstable detrusor contractionsUrology","part":{"pages":"839-844","volume":"61","issue":"4","extent":"6","text":"61(2003), 4, Seite 839-844","year":"2003"},"note":["Gesehen am 01.04.05","Ungezählte Beil.: Supplement"],"title":[{"title":"Urology","title_sort":"Urology"}],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"origin":[{"dateIssuedDisp":"25 March 2003","dateIssuedKey":"2003"}]} 
SRT |a BRAUNPETERSTIMULATIO2520