Fast rigid registration in radiation therapy

Based on a stochastic mutual information type matching and RPROP as stochastic optimizer, an interactive image-based registration of a CT volume onto two 2D images provided by a megavoltage system is presented. The matching process is based on semi-automatic pre-segmentation, an approximate 2D-2D ma...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Müller, Ulrich (VerfasserIn) , Hesser, Jürgen (VerfasserIn) , Walter, Cornelia (VerfasserIn) , Dobler, Barbara (VerfasserIn) , Lohr, Frank (VerfasserIn) , Wenz, Frederik (VerfasserIn)
Dokumenttyp: Kapitel/Artikel Konferenzschrift
Sprache:Englisch
Veröffentlicht: 2006
In: Medicine meets virtual reality 14
Year: 2006, Pages: 404-406
Online-Zugang: Volltext
Verfasserangaben:Ulrich Müller, Jürgen Hesser, Cornelia Walter, Barbara Dobler, Frank Lohr, Frederik Wenz

MARC

LEADER 00000caa a22000002c 4500
001 1795582065
003 DE-627
005 20230426163635.0
007 tu
008 220315s2006 xx ||||| 00| ||eng c
035 |a (DE-627)1795582065 
035 |a (DE-599)KXP1795582065 
035 |a (OCoLC)1341446060 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Müller, Ulrich  |e VerfasserIn  |0 (DE-588)125352503X  |0 (DE-627)1795732237  |4 aut 
245 1 0 |a Fast rigid registration in radiation therapy  |c Ulrich Müller, Jürgen Hesser, Cornelia Walter, Barbara Dobler, Frank Lohr, Frederik Wenz 
264 1 |c 2006 
300 |a 3 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Gesehen am 15.03.2022 
520 |a Based on a stochastic mutual information type matching and RPROP as stochastic optimizer, an interactive image-based registration of a CT volume onto two 2D images provided by a megavoltage system is presented. The matching process is based on semi-automatic pre-segmentation, an approximate 2D-2D matching with precomputed virtual projections (DRRs) followed by an accurate 3D-2D matching step. Our sample-based approach requires only a fraction of computed DRRs for 3D-2D. A simultaneous computation of the DRR rays and their perturbations in 6 dimensions speeds up the rendering process by a factor of 6.8. The complete registration process takes 5.6 +/- 2.3 seconds on a 3 GHz Pentium IV PC, being the fastest non-parallel approach for this sort of application the authors are aware of. 
650 4 |a Data Display 
650 4 |a Germany 
650 4 |a Radiotherapy, Computer-Assisted 
650 4 |a Tomography, X-Ray Computed 
700 1 |a Hesser, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1020647353  |0 (DE-627)691291071  |0 (DE-576)361513739  |4 aut 
700 1 |a Walter, Cornelia  |e VerfasserIn  |4 aut 
700 1 |a Dobler, Barbara  |e VerfasserIn  |0 (DE-588)1253242364  |0 (DE-627)1795266384  |4 aut 
700 1 |a Lohr, Frank  |e VerfasserIn  |0 (DE-588)1025307194  |0 (DE-627)72201967X  |0 (DE-576)37018694X  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
773 0 8 |i Enthalten in  |t Medicine meets virtual reality 14  |d Amsterdam : IOS Press, 2006  |g (2006), Seite 404-406  |h XX, 600 S.  |w (DE-627)51929713X  |w (DE-576)30898384X  |z 1586035835  |7 nnam  |a Fast rigid registration in radiation therapy 
773 1 8 |g year:2006  |g pages:404-406  |g extent:3  |a Fast rigid registration in radiation therapy 
776 0 8 |i Erscheint auch als  |n Online-Ausgabe  |a Müller, Ulrich  |t Fast rigid registration in radiation therapy  |d 2006  |w (DE-627)1795725494 
951 |a AR 
992 |a 20220315 
993 |a ConferencePaper 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |d 60000  |e 60000PW113310390  |e 63000PW113310390  |e 60000PW113310390  |k 0/60000/  |k 1/60000/63000/  |k 0/60000/  |p 6  |y j 
998 |g 1025307194  |a Lohr, Frank  |m 1025307194:Lohr, Frank  |d 60000  |d 63000  |e 60000PL1025307194  |e 63000PL1025307194  |k 0/60000/  |k 1/60000/63000/  |p 5 
998 |g 1253242364  |a Dobler, Barbara  |m 1253242364:Dobler, Barbara  |d 60000  |d 63000  |e 60000PD1253242364  |e 63000PD1253242364  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1020647353  |a Hesser, Jürgen  |m 1020647353:Hesser, Jürgen  |d 60000  |d 63000  |e 60000PH1020647353  |e 63000PH1020647353  |k 0/60000/  |k 1/60000/63000/  |p 2 
999 |a KXP-PPN1795582065  |e 4089254647 
BIB |a Y 
JSO |a {"note":["Gesehen am 15.03.2022"],"origin":[{"dateIssuedDisp":"2006","dateIssuedKey":"2006"}],"title":[{"title_sort":"Fast rigid registration in radiation therapy","title":"Fast rigid registration in radiation therapy"}],"type":{"bibl":"chapter"},"language":["eng"],"person":[{"display":"Müller, Ulrich","family":"Müller","given":"Ulrich","role":"aut"},{"role":"aut","given":"Jürgen","family":"Hesser","display":"Hesser, Jürgen"},{"display":"Walter, Cornelia","family":"Walter","role":"aut","given":"Cornelia"},{"given":"Barbara","role":"aut","family":"Dobler","display":"Dobler, Barbara"},{"family":"Lohr","display":"Lohr, Frank","given":"Frank","role":"aut"},{"given":"Frederik","role":"aut","display":"Wenz, Frederik","family":"Wenz"}],"relHost":[{"part":{"pages":"404-406","text":"(2006), Seite 404-406","year":"2006","extent":"3"},"type":{"bibl":"edited-book"},"origin":[{"publisherPlace":"Amsterdam ; Berlin [u.a.]","dateIssuedDisp":"2006","dateIssuedKey":"2006","publisher":"IOS Press"}],"titleAlt":[{"title":"Accelerating change in healthcare"}],"title":[{"title_sort":"Medicine meets virtual reality 14","subtitle":"accelerating change in healthcare: next medical toolkit ; [MMVR 14 proceedings]","title":"Medicine meets virtual reality 14"}],"relMultPart":[{"recId":"165668156","pubHistory":["1.1991 -"],"dispAlt":"Studies in health technology and informatics","id":{"zdb":["1088535-3"],"eki":["165668156"],"issn":["0926-9630"]},"disp":"Studies in health technology and informatics","language":["eng"],"part":{"number":["119"],"number_sort":["119"]},"origin":[{"publisher":"IOS Press","dateIssuedKey":"1991","publisherPlace":"Amsterdam ; Berlin [u.a.]","dateIssuedDisp":"1991-"}],"titleAlt":[{"title":"HTI"},{"title":"Health technology and informatics"}],"title":[{"title_sort":"Studies in health technology and informatics","title":"Studies in health technology and informatics"}],"type":{"bibl":"serial"}}],"disp":"Fast rigid registration in radiation therapyMedicine meets virtual reality 14","id":{"isbn":["1586035835"],"eki":["51929713X"]},"note":["Literaturangaben"],"language":["eng"],"person":[{"family":"Westwood","display":"Westwood, James D.","role":"edt","given":"James D."}],"corporate":[{"display":"MMVR (14, 2006, Long Beach, Calif.)","role":"oth"}],"physDesc":[{"extent":"XX, 600 S.","noteIll":"Ill., graph. Darst."}],"name":{"displayForm":["ed. by James D. Westwood ..."]},"recId":"51929713X"}],"id":{"eki":["1795582065"]},"name":{"displayForm":["Ulrich Müller, Jürgen Hesser, Cornelia Walter, Barbara Dobler, Frank Lohr, Frederik Wenz"]},"physDesc":[{"extent":"3 S."}],"recId":"1795582065"} 
SRT |a MUELLERULRFASTRIGIDR2006