The effect of hyoid suspension in a multilevel surgery concept for obstructive sleep apnea

OBJECTIVE: This study investigated the outcome of the hyoid suspension as a part of a multilevel surgery protocol., STUDY DESIGN AND SETTING: Eighty-three patients with obstructive sleep apnea (OSA) underwent a multilevel surgical treatment because of continuous positive-airway pressure intolerance,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Baisch, Alexander (VerfasserIn) , Maurer, Joachim T. (VerfasserIn) , Hörmann, Karl (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: May 1, 2006
In: Otolaryngology - head and neck surgery
Year: 2006, Jahrgang: 134, Heft: 5, Pages: 856-861
ISSN:1097-6817
DOI:10.1016/j.otohns.2006.01.015
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.otohns.2006.01.015
Volltext
Verfasserangaben:Alexander Baisch, MD, Joachim Theodor Maurer, MD, and Karl Hörmann, MD (Mannheim, Germany)

MARC

LEADER 00000caa a2200000 c 4500
001 1796026581
003 DE-627
005 20220820150348.0
007 cr uuu---uuuuu
008 220318s2006 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.otohns.2006.01.015  |2 doi 
035 |a (DE-627)1796026581 
035 |a (DE-599)KXP1796026581 
035 |a (OCoLC)1341445961 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Baisch, Alexander  |d 1975-  |e VerfasserIn  |0 (DE-588)124001831  |0 (DE-627)706504704  |0 (DE-576)185534988  |4 aut 
245 1 4 |a The effect of hyoid suspension in a multilevel surgery concept for obstructive sleep apnea  |c Alexander Baisch, MD, Joachim Theodor Maurer, MD, and Karl Hörmann, MD (Mannheim, Germany) 
264 1 |c May 1, 2006 
300 |b Diagramme 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 18.03.2022 
520 |a OBJECTIVE: This study investigated the outcome of the hyoid suspension as a part of a multilevel surgery protocol., STUDY DESIGN AND SETTING: Eighty-three patients with obstructive sleep apnea (OSA) underwent a multilevel surgical treatment because of continuous positive-airway pressure intolerance, 67 with the hyoid suspension and 16 without the hyoid suspension. All patients underwent a pre- and postoperative polysomnography in the sleep laboratory., RESULTS: The mean preoperative apnea hypopnea index (AHI) was 36.4 ± 21.2 and 19.4 ± 19.7 postoperatively for all patients (P < 0.0001). Further statistically significant changes were found for the arousal index, the oxygen saturation, and the daytime sleepiness. No statistically significant change was found for body mass index. In the group of patients treated without the hyoid suspension, the AHI did not decrease statistically significant. After surgery, 59.7% of the subjects with the hyoid suspension were regarded as cured., CONCLUSION: Multilevel surgery including the hyoid suspension is an effective treatment in subgroup of OSA patients., EBM rating: C-4 
700 1 |a Maurer, Joachim T.  |d 1964-  |e VerfasserIn  |0 (DE-588)1032974400  |0 (DE-627)739828711  |0 (DE-576)380442337  |4 aut 
700 1 |a Hörmann, Karl  |d 1948-  |e VerfasserIn  |0 (DE-588)130123749  |0 (DE-627)49171193X  |0 (DE-576)266607438  |4 aut 
773 0 8 |i Enthalten in  |t Otolaryngology - head and neck surgery  |d Oxford [u.a.] : Wiley-Blackwell, 1978  |g 134(2006), 5 vom: Mai, Seite 856-861  |h Online-Ressource  |w (DE-627)320470407  |w (DE-600)2008453-5  |w (DE-576)094080550  |x 1097-6817  |7 nnas  |a The effect of hyoid suspension in a multilevel surgery concept for obstructive sleep apnea 
773 1 8 |g volume:134  |g year:2006  |g number:5  |g month:05  |g pages:856-861  |g extent:6  |a The effect of hyoid suspension in a multilevel surgery concept for obstructive sleep apnea 
856 4 0 |u https://doi.org/10.1016/j.otohns.2006.01.015  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220318 
993 |a Article 
994 |a 2006 
998 |g 130123749  |a Hörmann, Karl  |m 130123749:Hörmann, Karl  |d 60000  |d 62100  |e 60000PH130123749  |e 62100PH130123749  |k 0/60000/  |k 1/60000/62100/  |p 3  |y j 
998 |g 1032974400  |a Maurer, Joachim T.  |m 1032974400:Maurer, Joachim T.  |d 60000  |d 62100  |e 60000PM1032974400  |e 62100PM1032974400  |k 0/60000/  |k 1/60000/62100/  |p 2 
998 |g 124001831  |a Baisch, Alexander  |m 124001831:Baisch, Alexander  |d 60000  |d 62100  |e 60000PB124001831  |e 62100PB124001831  |k 0/60000/  |k 1/60000/62100/  |p 1  |x j 
999 |a KXP-PPN1796026581  |e 4095165456 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Alexander","display":"Baisch, Alexander","family":"Baisch","role":"aut"},{"family":"Maurer","display":"Maurer, Joachim T.","given":"Joachim T.","role":"aut"},{"family":"Hörmann","given":"Karl","display":"Hörmann, Karl","role":"aut"}],"origin":[{"dateIssuedDisp":"May 1, 2006","dateIssuedKey":"2006"}],"name":{"displayForm":["Alexander Baisch, MD, Joachim Theodor Maurer, MD, and Karl Hörmann, MD (Mannheim, Germany)"]},"recId":"1796026581","title":[{"title":"The effect of hyoid suspension in a multilevel surgery concept for obstructive sleep apnea","title_sort":"effect of hyoid suspension in a multilevel surgery concept for obstructive sleep apnea"}],"language":["eng"],"physDesc":[{"extent":"6 S.","noteIll":"Diagramme"}],"id":{"doi":["10.1016/j.otohns.2006.01.015"],"eki":["1796026581"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 18.03.2022"],"relHost":[{"pubHistory":["Volume 86, issue 1 (1978) [?]-"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"The effect of hyoid suspension in a multilevel surgery concept for obstructive sleep apneaOtolaryngology - head and neck surgery","recId":"320470407","titleAlt":[{"title":"OTO"}],"language":["eng"],"id":{"eki":["320470407"],"issn":["1097-6817"],"zdb":["2008453-5"]},"part":{"volume":"134","text":"134(2006), 5 vom: Mai, Seite 856-861","year":"2006","pages":"856-861","extent":"6","issue":"5"},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 12.05.2023"],"origin":[{"dateIssuedKey":"1978","publisherPlace":"Oxford [u.a.] ; St. Louis, Mo. ; New York, NY ; Thousand Oaks, Calif.","publisher":"Wiley-Blackwell ; Mosby ; Elsevier ; Sage","dateIssuedDisp":"1978-"}],"title":[{"title":"Otolaryngology - head and neck surgery","subtitle":"official publication of the American Academy of Otolaryngology, Head and Neck Surgery Foundation, Inc. and the American Academy of Otolaryngic Allergy","title_sort":"Otolaryngology - head and neck surgery"}]}]} 
SRT |a BAISCHALEXEFFECTOFHY1200