Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients: image quality and impact of patient characteristics

The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre study included patients scheduled for aortic C...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fink, Matthias A. (VerfasserIn) , Hartmann, Sibylle (VerfasserIn) , Melzig, Claudius (VerfasserIn) , Steuwe, Andrea (VerfasserIn) , Partovi, Sasan (VerfasserIn) , Böckler, Dittmar (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Rengier, Fabian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 10 March 2022
In: Diagnostics
Year: 2022, Jahrgang: 12, Heft: 3, Pages: 1-13
ISSN:2075-4418
DOI:10.3390/diagnostics12030675
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.3390/diagnostics12030675
Verlag, kostenfrei, Volltext: https://www.mdpi.com/2075-4418/12/3/675
Volltext
Verfasserangaben:Matthias A. Fink, Sibylle Stoll, Claudius Melzig, Andrea Steuwe, Sasan Partovi, Dittmar Böckler, Hans-Ulrich Kauczor and Fabian Rengier

MARC

LEADER 00000caa a2200000 c 4500
001 1797633872
003 DE-627
005 20230816131046.0
007 cr uuu---uuuuu
008 220405s2022 xx |||||o 00| ||eng c
024 7 |a 10.3390/diagnostics12030675  |2 doi 
035 |a (DE-627)1797633872 
035 |a (DE-599)KXP1797633872 
035 |a (OCoLC)1341458405 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Fink, Matthias A.  |d 1989-  |e VerfasserIn  |0 (DE-588)1193521289  |0 (DE-627)1672256518  |4 aut 
245 1 0 |a Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients  |b image quality and impact of patient characteristics  |c Matthias A. Fink, Sibylle Stoll, Claudius Melzig, Andrea Steuwe, Sasan Partovi, Dittmar Böckler, Hans-Ulrich Kauczor and Fabian Rengier 
264 1 |c 10 March 2022 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.04.2022 
520 |a The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre study included patients scheduled for aortic CTA between November 2017 and August 2020 without symptoms of high-grade heart failure. A BMI-adapted protocol was used: Group A/Group B, BMI < 30/≥ 30 kg/m2, tube potential 80/100 kVp, total iodine dose 14.5/17.4 g. Intraindividual comparison with the institutional clinical routine aortic CTA protocol was performed. The final study cohort comprised 161 patients (mean 71.1 ± 9.4 years, 32 women), thereof 126 patients in Group A (mean BMI 25.4 ± 2.8 kg/m2) and 35 patients in Group B (34.0 ± 3.4 kg/m2). Mean attenuation over five aortoiliac measurement positions for Group A/B was 354.9 ± 78.2/262.1 ± 73.0 HU. Mean effective dose for Group A/B was 3.05 ± 0.46/6.02 ± 1.14 mSv. Intraindividual comparison in 50 patients demonstrated effective dose savings for Group A/B of 34.4 ± 14.5/25.4 ± 14.1% (both p < 0.001), and iodine dose savings for Group A/B of 54/44.8%. Regression analysis showed that female sex and increasing age were independently associated with higher vascular attenuation. In conclusion, BMI-adapted, low-radiation and low-iodine dose CTA of the thoracoabdominal aorta delivers diagnostic image quality in non-obese and obese patients without symptoms of high-grade heart failure, with superior image quality in females and the elderly. 
650 4 |a aorta 
650 4 |a computed tomography angiography 
650 4 |a contrast media 
650 4 |a obesity 
650 4 |a radiation dosage 
700 1 |a Hartmann, Sibylle  |d 1992-  |e VerfasserIn  |0 (DE-588)1254846182  |0 (DE-627)1797633325  |4 aut 
700 1 |a Melzig, Claudius  |d 1986-  |e VerfasserIn  |0 (DE-588)1072780445  |0 (DE-627)828231389  |0 (DE-576)434238570  |4 aut 
700 1 |a Steuwe, Andrea  |e VerfasserIn  |0 (DE-588)1172688753  |0 (DE-627)1041322763  |0 (DE-576)514738383  |4 aut 
700 1 |a Partovi, Sasan  |d 1986-  |e VerfasserIn  |0 (DE-588)1019808713  |0 (DE-627)687017564  |0 (DE-576)358894794  |4 aut 
700 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Rengier, Fabian  |d 1986-  |e VerfasserIn  |0 (DE-588)139065865  |0 (DE-627)608103284  |0 (DE-576)309935873  |4 aut 
773 0 8 |i Enthalten in  |t Diagnostics  |d Basel : MDPI, 2011  |g 12(2022), 3, Artikel-ID 675, Seite 1-13  |h Online-Ressource  |w (DE-627)718627814  |w (DE-600)2662336-5  |w (DE-576)365413917  |x 2075-4418  |7 nnas  |a Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients image quality and impact of patient characteristics 
773 1 8 |g volume:12  |g year:2022  |g number:3  |g elocationid:675  |g pages:1-13  |g extent:13  |a Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients image quality and impact of patient characteristics 
856 4 0 |u https://doi.org/10.3390/diagnostics12030675  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.mdpi.com/2075-4418/12/3/675  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20220405 
993 |a Article 
994 |a 2022 
998 |g 139065865  |a Rengier, Fabian  |m 139065865:Rengier, Fabian  |d 910000  |d 911400  |e 910000PR139065865  |e 911400PR139065865  |k 0/910000/  |k 1/910000/911400/  |p 8  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 6 
998 |g 1072780445  |a Melzig, Claudius  |m 1072780445:Melzig, Claudius  |d 910000  |d 911400  |e 910000PM1072780445  |e 911400PM1072780445  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 1254846182  |a Hartmann, Sibylle  |m 1254846182:Hartmann, Sibylle  |d 910000  |d 911400  |e 910000PH1254846182  |e 911400PH1254846182  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1193521289  |a Fink, Matthias A.  |m 1193521289:Fink, Matthias A.  |d 910000  |d 911400  |e 910000PF1193521289  |e 911400PF1193521289  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1797633872  |e 4112210361 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"name":{"displayForm":["Matthias A. Fink, Sibylle Stoll, Claudius Melzig, Andrea Steuwe, Sasan Partovi, Dittmar Böckler, Hans-Ulrich Kauczor and Fabian Rengier"]},"language":["eng"],"title":[{"subtitle":"image quality and impact of patient characteristics","title":"Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients","title_sort":"Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients"}],"person":[{"family":"Fink","role":"aut","given":"Matthias A.","display":"Fink, Matthias A."},{"display":"Hartmann, Sibylle","given":"Sibylle","role":"aut","family":"Hartmann"},{"family":"Melzig","role":"aut","given":"Claudius","display":"Melzig, Claudius"},{"family":"Steuwe","role":"aut","given":"Andrea","display":"Steuwe, Andrea"},{"family":"Partovi","role":"aut","display":"Partovi, Sasan","given":"Sasan"},{"role":"aut","given":"Dittmar","display":"Böckler, Dittmar","family":"Böckler"},{"display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","role":"aut","family":"Kauczor"},{"family":"Rengier","role":"aut","given":"Fabian","display":"Rengier, Fabian"}],"id":{"eki":["1797633872"],"doi":["10.3390/diagnostics12030675"]},"physDesc":[{"extent":"13 S."}],"note":["Gesehen am 05.04.2022"],"origin":[{"dateIssuedDisp":"10 March 2022","dateIssuedKey":"2022"}],"recId":"1797633872","relHost":[{"pubHistory":["1.2011 -"],"note":["Gesehen am 28.05.2020"],"origin":[{"dateIssuedKey":"2011","publisher":"MDPI","dateIssuedDisp":"2011-","publisherPlace":"Basel"}],"recId":"718627814","language":["eng"],"id":{"issn":["2075-4418"],"eki":["718627814"],"zdb":["2662336-5"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients image quality and impact of patient characteristicsDiagnostics","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Diagnostics","subtitle":"open access journal","title":"Diagnostics"}],"part":{"issue":"3","volume":"12","extent":"13","text":"12(2022), 3, Artikel-ID 675, Seite 1-13","year":"2022","pages":"1-13"}}]} 
SRT |a FINKMATTHIPROSPECTIV1020