Increased soluble VCAM-1 serum levels in preeclampsia are not correlated to urinary excretion or circadian blood pressure rhythm
Objective : Soluble vascular cell adhesion molecule-1 (VCAM-1) is known to be elevated in serum of patients with preeclampsia, but there are no data available on the significance of urinary VCAM-1 excretion in preeclampsia. The aim of our study was to uncover possible circadian rhythms of VCAM-1 pla...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
1. Juni 2005
|
| In: |
Journal of perinatal medicine
Year: 2005, Jahrgang: 33, Heft: 2, Pages: 144-148 |
| ISSN: | 1619-3997 |
| DOI: | 10.1515/JPM.2005.027 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1515/JPM.2005.027 Verlag, lizenzpflichtig, Volltext: https://www.degruyterbrill.com/document/doi/10.1515/JPM.2005.027/html |
| Verfasserangaben: | W. Heyl, B. Heintz, F. Reister, S. Harwig, K. Witte, B. Lemmer and W. Rath |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1798094320 | ||
| 003 | DE-627 | ||
| 005 | 20250530003457.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220407s2005 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1515/JPM.2005.027 |2 doi | |
| 035 | |a (DE-627)1798094320 | ||
| 035 | |a (DE-599)KXP1798094320 | ||
| 035 | |a (OCoLC)1341458696 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Heyl, Wolfgang |e VerfasserIn |0 (DE-588)1255034491 |0 (DE-627)1798095033 |4 aut | |
| 245 | 1 | 0 | |a Increased soluble VCAM-1 serum levels in preeclampsia are not correlated to urinary excretion or circadian blood pressure rhythm |c W. Heyl, B. Heintz, F. Reister, S. Harwig, K. Witte, B. Lemmer and W. Rath |
| 264 | 1 | |c 1. Juni 2005 | |
| 300 | |a 5 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 07.04.2022 | ||
| 520 | |a Objective : Soluble vascular cell adhesion molecule-1 (VCAM-1) is known to be elevated in serum of patients with preeclampsia, but there are no data available on the significance of urinary VCAM-1 excretion in preeclampsia. The aim of our study was to uncover possible circadian rhythms of VCAM-1 plasma levels and urinary VCAM-1 excretion in uncomplicated and hypertensive pregnancies and to ascertain their relation to blood pressure. Study design : A total of 10 normotensive and 10 preeclamptic pregnant women were included in this study. Venous blood was collected hourly, and urine samples were taken every 2 h over a period of 24 h. VCAM-1 levels were determined by ELISA. We compared these results with the circadian blood pressure rhythm. Results : The median VCAM-1 plasma levels were significantly (P<0.01) increased in preeclamptic patients (851.5 ng/mL) in comparison to normotensive pregnant women (659.3 ng/mL) without any circadian rhythm being apparent; however, the urinary excretion of VCAM-1 showed a typical circadian rhythm, with a higher excretion rate during daytime. Conclusion : For the first time we have demonstrated that urinary VCAM-1 excretion in pregnancy shows a circadian rhythm without correlation to plasma levels or the circadian blood pressure rhythm. In contrast, VCAM-1 serum levels did not show a diurnal rhythm. We assume that VCAM-1 serum levels do not correlate with systemic blood pressure or urinary excretion. | ||
| 650 | 4 | |a Adhesion molecules | |
| 650 | 4 | |a blood pressure | |
| 650 | 4 | |a circadian rhythm | |
| 650 | 4 | |a preeclampsia | |
| 700 | 1 | |a Heintz, B. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Reister, F. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Harwig, S. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Witte, Klaus |d 1962- |e VerfasserIn |0 (DE-588)1104517922 |0 (DE-627)861919793 |0 (DE-576)471123668 |4 aut | |
| 700 | 1 | |a Lemmer, Björn |d 1942- |e VerfasserIn |0 (DE-588)10728605X |0 (DE-627)623794632 |0 (DE-576)32156345X |4 aut | |
| 700 | 1 | |a Rath, W. |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of perinatal medicine |d Berlin [u.a.] : de Gruyter, 1973 |g 33(2005), 2, Seite 144-148 |h Online-Ressource |w (DE-627)266881300 |w (DE-600)1467968-1 |w (DE-576)07514607X |x 1619-3997 |7 nnas |a Increased soluble VCAM-1 serum levels in preeclampsia are not correlated to urinary excretion or circadian blood pressure rhythm |
| 773 | 1 | 8 | |g volume:33 |g year:2005 |g number:2 |g pages:144-148 |g extent:5 |a Increased soluble VCAM-1 serum levels in preeclampsia are not correlated to urinary excretion or circadian blood pressure rhythm |
| 856 | 4 | 0 | |u https://doi.org/10.1515/JPM.2005.027 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.degruyterbrill.com/document/doi/10.1515/JPM.2005.027/html |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220407 | ||
| 993 | |a Article | ||
| 994 | |a 2005 | ||
| 998 | |g 10728605X |a Lemmer, Björn |m 10728605X:Lemmer, Björn |d 60000 |d 65400 |d 60000 |e 60000PL10728605X |e 65400PL10728605X |e 60000PL10728605X |k 0/60000/ |k 1/60000/65400/ |k 0/60000/ |p 6 | ||
| 998 | |g 1104517922 |a Witte, Klaus |m 1104517922:Witte, Klaus |d 60000 |d 65400 |d 60000 |e 60000PW1104517922 |e 65400PW1104517922 |e 60000PW1104517922 |k 0/60000/ |k 1/60000/65400/ |k 0/60000/ |p 5 | ||
| 999 | |a KXP-PPN1798094320 |e 4113102503 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"title":[{"title_sort":"Journal of perinatal medicine","title":"Journal of perinatal medicine","subtitle":"official journal of the World Association of Perinatal Medicine"}],"pubHistory":["1.1973 -"],"part":{"issue":"2","pages":"144-148","year":"2005","extent":"5","volume":"33","text":"33(2005), 2, Seite 144-148"},"note":["Gesehem am 06.05.2025"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Increased soluble VCAM-1 serum levels in preeclampsia are not correlated to urinary excretion or circadian blood pressure rhythmJournal of perinatal medicine","recId":"266881300","language":["eng"],"origin":[{"publisher":"de Gruyter","dateIssuedKey":"1973","dateIssuedDisp":"1973-","publisherPlace":"Berlin [u.a.]"}],"id":{"issn":["1619-3997"],"doi":["10.1515/jpm"],"eki":["266881300"],"zdb":["1467968-1"]},"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"5 S."}],"name":{"displayForm":["W. Heyl, B. Heintz, F. Reister, S. Harwig, K. Witte, B. Lemmer and W. Rath"]},"id":{"doi":["10.1515/JPM.2005.027"],"eki":["1798094320"]},"origin":[{"dateIssuedDisp":"1. Juni 2005","dateIssuedKey":"2005"}],"language":["eng"],"recId":"1798094320","note":["Gesehen am 07.04.2022"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"roleDisplay":"VerfasserIn","display":"Heyl, Wolfgang","role":"aut","family":"Heyl","given":"Wolfgang"},{"roleDisplay":"VerfasserIn","display":"Heintz, B.","role":"aut","family":"Heintz","given":"B."},{"given":"F.","family":"Reister","role":"aut","display":"Reister, F.","roleDisplay":"VerfasserIn"},{"display":"Harwig, S.","roleDisplay":"VerfasserIn","role":"aut","family":"Harwig","given":"S."},{"role":"aut","display":"Witte, Klaus","roleDisplay":"VerfasserIn","given":"Klaus","family":"Witte"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Lemmer, Björn","given":"Björn","family":"Lemmer"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Rath, W.","given":"W.","family":"Rath"}],"title":[{"title":"Increased soluble VCAM-1 serum levels in preeclampsia are not correlated to urinary excretion or circadian blood pressure rhythm","title_sort":"Increased soluble VCAM-1 serum levels in preeclampsia are not correlated to urinary excretion or circadian blood pressure rhythm"}]} | ||
| SRT | |a HEYLWOLFGAINCREASEDS1200 | ||