Diffusion MRI in peripheral nerves: optimized b values and the role of non-Gaussian diffusion

Background - - Diffusion-weighted imaging (DWI) provides specific in vivo information about tissue microstructure, which is increasingly recognized for various applications outside the central nervous system. However, standard sequence parameters are commonly adopted from optimized central nervous...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fösleitner, Olivia (VerfasserIn) , Sulaj, Alba (VerfasserIn) , Sturm, Volker Jörg Friedrich (VerfasserIn) , Kronlage, Moritz (VerfasserIn) , Godel, Tim (VerfasserIn) , Preisner, Fabian (VerfasserIn) , Nawroth, Peter Paul (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Schwarz, Daniel (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2022
In: Radiology
Year: 2022, Jahrgang: 302, Heft: 1, Pages: 153-161
ISSN:1527-1315
DOI:10.1148/radiol.2021204740
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1148/radiol.2021204740
Verlag, lizenzpflichtig, Volltext: https://pubs.rsna.org/doi/10.1148/radiol.2021204740
Volltext
Verfasserangaben:Olivia Foesleitner, MD, PhD, Alba Sulaj, MD, Volker Sturm, PhD, Moritz Kronlage, MD, Tim Godel, MD, Fabian Preisner, MD, Peter Paul Nawroth, MD, Martin Bendszus, MD, Sabine Heiland, PhD, Daniel Schwarz, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1799291340
003 DE-627
005 20231002111845.0
007 cr uuu---uuuuu
008 220412s2022 xx |||||o 00| ||eng c
024 7 |a 10.1148/radiol.2021204740  |2 doi 
035 |a (DE-627)1799291340 
035 |a (DE-599)KXP1799291340 
035 |a (OCoLC)1341458881 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Fösleitner, Olivia  |e VerfasserIn  |0 (DE-588)1255100338  |0 (DE-627)1798288249  |4 aut 
245 1 0 |a Diffusion MRI in peripheral nerves  |b optimized b values and the role of non-Gaussian diffusion  |c Olivia Foesleitner, MD, PhD, Alba Sulaj, MD, Volker Sturm, PhD, Moritz Kronlage, MD, Tim Godel, MD, Fabian Preisner, MD, Peter Paul Nawroth, MD, Martin Bendszus, MD, Sabine Heiland, PhD, Daniel Schwarz, MD 
264 1 |c 2022 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: Oct 19 2021 
500 |a Gesehen am 12.04.2022 
520 |a Background - - Diffusion-weighted imaging (DWI) provides specific in vivo information about tissue microstructure, which is increasingly recognized for various applications outside the central nervous system. However, standard sequence parameters are commonly adopted from optimized central nervous system protocols, thus potentially neglecting differences in tissue-specific diffusional behavior. - - Purpose - - To characterize the optimal tissue-specific diffusion imaging weighting scheme over the b domain in peripheral nerves under physiologic and pathologic conditions. - - Materials and Methods - - In this prospective cross-sectional study, 3-T MR neurography of the sciatic nerve was performed in healthy volunteers (n = 16) and participants with type 2 diabetes (n = 12). For DWI, 16 b values in the range of 0-1500 sec/mm2 were acquired in axial and radial diffusion directions of the nerve. With a region of interest-based approach, diffusion-weighted signal behavior as a function of b was estimated using standard monoexponential, biexponential, and kurtosis fitting. Goodness of fit was assessed to determine the optimal b value for two-point DWI/diffusion tensor imaging (DTI). - - Results - - Non-Gaussian diffusional behavior was observed beyond b values of 600 sec/mm2 in the axial and 800 sec/mm2 in the radial diffusion direction in both participants with diabetes and healthy volunteers. Accordingly, the biexponential and kurtosis models achieved a better curve fit compared with the standard monoexponential model (Akaike information criterion >99.9% in all models), but the kurtosis model was preferred in the majority of cases. Significant differences between healthy volunteers and participants with diabetes were found in the kurtosis-derived parameters Dk and K. The results suggest an upper bound b value of approximately 700 sec/mm2 for optimal standard DWI/DTI in peripheral nerve applications. - - Conclusion - - In MR neurography, an ideal standard diffusion-weighted imaging/diffusion tensor imaging protocol with b = 700 sec/mm2 is suggested. This is substantially lower than in the central nervous system due to early-occurring non-Gaussian diffusion behavior and emphasizes the need for tissue-specific b value optimization. Including higher b values, kurtosis-derived parameters may represent promising novel imaging markers of peripheral nerve disease. - - ©RSNA, 2021 - - Online supplemental material is available for this article. - - See also the editorial by Jang and Du in this issue. 
700 1 |a Sulaj, Alba  |d 1986-  |e VerfasserIn  |0 (DE-588)1062919815  |0 (DE-627)807036897  |0 (DE-576)420262415  |4 aut 
700 1 |a Sturm, Volker Jörg Friedrich  |d 1980-  |e VerfasserIn  |0 (DE-588)1096228149  |0 (DE-627)856637238  |0 (DE-576)467929971  |4 aut 
700 1 |a Kronlage, Moritz  |d 1984-  |e VerfasserIn  |0 (DE-588)1027093531  |0 (DE-627)728260050  |0 (DE-576)37246887X  |4 aut 
700 1 |a Godel, Tim  |d 1985-  |e VerfasserIn  |0 (DE-588)1153513471  |0 (DE-627)1014950384  |0 (DE-576)500281394  |4 aut 
700 1 |a Preisner, Fabian  |d 1988-  |e VerfasserIn  |0 (DE-588)1196155534  |0 (DE-627)167801284X  |4 aut 
700 1 |a Nawroth, Peter Paul  |d 1954-  |e VerfasserIn  |0 (DE-588)1020504897  |0 (DE-627)69123941X  |0 (DE-576)360517692  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Schwarz, Daniel  |d 1983-  |e VerfasserIn  |0 (DE-588)1104866781  |0 (DE-627)862224926  |0 (DE-576)472943065  |4 aut 
773 0 8 |i Enthalten in  |t Radiology  |d Oak Brook, Ill. : Soc., 1923  |g 302(2022), 1, Seite 153-161  |h Online-Ressource  |w (DE-627)320487253  |w (DE-600)2010588-5  |w (DE-576)094056706  |x 1527-1315  |7 nnas  |a Diffusion MRI in peripheral nerves optimized b values and the role of non-Gaussian diffusion 
773 1 8 |g volume:302  |g year:2022  |g number:1  |g pages:153-161  |g extent:9  |a Diffusion MRI in peripheral nerves optimized b values and the role of non-Gaussian diffusion 
856 4 0 |u https://doi.org/10.1148/radiol.2021204740  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://pubs.rsna.org/doi/10.1148/radiol.2021204740  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220412 
993 |a Article 
994 |a 2022 
998 |g 1104866781  |a Schwarz, Daniel  |m 1104866781:Schwarz, Daniel  |d 910000  |d 911100  |e 910000PS1104866781  |e 911100PS1104866781  |k 0/910000/  |k 1/910000/911100/  |p 10  |y j 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 9 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 1020504897  |a Nawroth, Peter Paul  |m 1020504897:Nawroth, Peter Paul  |d 50000  |e 50000PN1020504897  |k 0/50000/  |p 7 
998 |g 1196155534  |a Preisner, Fabian  |m 1196155534:Preisner, Fabian  |d 910000  |d 911100  |e 910000PP1196155534  |e 911100PP1196155534  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 1153513471  |a Godel, Tim  |m 1153513471:Godel, Tim  |d 910000  |d 911100  |d 50000  |e 910000PG1153513471  |e 911100PG1153513471  |e 50000PG1153513471  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 5 
998 |g 1027093531  |a Kronlage, Moritz  |m 1027093531:Kronlage, Moritz  |d 910000  |d 911100  |d 50000  |e 910000PK1027093531  |e 911100PK1027093531  |e 50000PK1027093531  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 4 
998 |g 1096228149  |a Sturm, Volker Jörg Friedrich  |m 1096228149:Sturm, Volker Jörg Friedrich  |d 910000  |d 911100  |e 910000PS1096228149  |e 911100PS1096228149  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 1062919815  |a Sulaj, Alba  |m 1062919815:Sulaj, Alba  |d 910000  |d 910100  |e 910000PS1062919815  |e 910100PS1062919815  |k 0/910000/  |k 1/910000/910100/  |p 2 
998 |g 1255100338  |a Fösleitner, Olivia  |m 1255100338:Fösleitner, Olivia  |d 910000  |d 911100  |e 910000PF1255100338  |e 911100PF1255100338  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1799291340  |e 4116681490 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Olivia Foesleitner, MD, PhD, Alba Sulaj, MD, Volker Sturm, PhD, Moritz Kronlage, MD, Tim Godel, MD, Fabian Preisner, MD, Peter Paul Nawroth, MD, Martin Bendszus, MD, Sabine Heiland, PhD, Daniel Schwarz, MD"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1799291340","id":{"doi":["10.1148/radiol.2021204740"],"eki":["1799291340"]},"note":["Published online: Oct 19 2021","Gesehen am 12.04.2022"],"origin":[{"dateIssuedDisp":"2022","dateIssuedKey":"2022"}],"title":[{"title":"Diffusion MRI in peripheral nerves","title_sort":"Diffusion MRI in peripheral nerves","subtitle":"optimized b values and the role of non-Gaussian diffusion"}],"person":[{"given":"Olivia","family":"Fösleitner","role":"aut","display":"Fösleitner, Olivia"},{"display":"Sulaj, Alba","role":"aut","family":"Sulaj","given":"Alba"},{"display":"Sturm, Volker Jörg Friedrich","role":"aut","given":"Volker Jörg Friedrich","family":"Sturm"},{"family":"Kronlage","given":"Moritz","display":"Kronlage, Moritz","role":"aut"},{"display":"Godel, Tim","role":"aut","family":"Godel","given":"Tim"},{"given":"Fabian","family":"Preisner","display":"Preisner, Fabian","role":"aut"},{"role":"aut","display":"Nawroth, Peter Paul","given":"Peter Paul","family":"Nawroth"},{"given":"Martin","family":"Bendszus","display":"Bendszus, Martin","role":"aut"},{"family":"Heiland","given":"Sabine","role":"aut","display":"Heiland, Sabine"},{"given":"Daniel","family":"Schwarz","role":"aut","display":"Schwarz, Daniel"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Oak Brook, Ill.","dateIssuedKey":"1923","dateIssuedDisp":"1923-","publisher":"Soc."}],"note":["Fortsetzung der Druck-Ausgabe","Gesehen 07.11.22"],"pubHistory":["1.1923 -"],"id":{"issn":["1527-1315"],"eki":["320487253"],"zdb":["2010588-5"]},"recId":"320487253","name":{"displayForm":["The Radiological Society of North America"]},"part":{"extent":"9","volume":"302","year":"2022","issue":"1","pages":"153-161","text":"302(2022), 1, Seite 153-161"},"corporate":[{"display":"Radiological Society of North America","role":"isb"}],"title":[{"title":"Radiology","title_sort":"Radiology"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Diffusion MRI in peripheral nerves optimized b values and the role of non-Gaussian diffusionRadiology","language":["eng"]}],"physDesc":[{"extent":"9 S."}]} 
SRT |a FOESLEITNEDIFFUSIONM2022