Remote sensing array (RSA) for linac beam monitoring
The purpose of the present work is to evaluate the feasibility of a novel real-time beam monitoring device for medical linacs which remotely senses charge carriers produced in air by the beam without intersecting and attenuating the beamline. The primary goal is to elaborate a theoretical concept of...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
24 February 2022
|
| In: |
Physics in medicine and biology
Year: 2022, Jahrgang: 67, Heft: 5, Pages: 1-18 |
| ISSN: | 1361-6560 |
| DOI: | 10.1088/1361-6560/ac530d |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/ac530d |
| Verfasserangaben: | Robert Lauber, Davide Brivio, Erno Sajo, Jürgen Hesser and Piotr Zygmanski |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1800509227 | ||
| 003 | DE-627 | ||
| 005 | 20251204123526.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220428s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1088/1361-6560/ac530d |2 doi | |
| 035 | |a (DE-627)1800509227 | ||
| 035 | |a (DE-599)KXP1800509227 | ||
| 035 | |a (OCoLC)1341459395 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Lauber, Robert |e VerfasserIn |0 (DE-588)1256390275 |0 (DE-627)1800508964 |4 aut | |
| 245 | 1 | 0 | |a Remote sensing array (RSA) for linac beam monitoring |c Robert Lauber, Davide Brivio, Erno Sajo, Jürgen Hesser and Piotr Zygmanski |
| 264 | 1 | |c 24 February 2022 | |
| 300 | |a 18 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 28.04.2022 | ||
| 520 | |a The purpose of the present work is to evaluate the feasibility of a novel real-time beam monitoring device for medical linacs which remotely senses charge carriers produced in air by the beam without intersecting and attenuating the beamline. The primary goal is to elaborate a theoretical concept of a possible detector geometry and underlying physical model that allows for determination of clinically relevant beam data in real time, namely MLC leaf positions and dose rate. The detector consists of two opposing electrode arrays arranged in two possible orientations around the beamline. Detection of charge carriers is governed by electromagnetic principles described by Shockley-Ramo theorem. Ions produced by ionization of the air column upstream of patient move laterally in an external electric field. According to the method of images, mirror charges and mirror currents are formed in the strip electrodes. Determination of MU rate and MLC positions using the measured signal requires solution of an inverse problem. In the present work we adopted a Least-Square approach and characterized detector response and sensitivity to detection of beam properties for different electrode geometries and MLC shapes. Results were dependent on MLC field shape and the leaf position within the active volume. The accuracy of determination of leaf positions were in the sub-mm range (up to 0.25-1 mm). Additionally, detector sensitivity was quantified by simulating ions/pulse delivered with a radiation transport deterministic computation in 1D in CEPXS/ONEDANT. For a 6 MV linac pulse, signal amplitude per pulse was estimated to be in the lower pA to fA range. We computationally demonstrated feasibility of the remote sensing detector capable of measuring beam parameters such as MLC leaf positions and dose range for each pulse. Future work should focus on optimizing the electrode geometry to increase sensitivity and better reconstruction algorithms to provide more accurate solutions of the inverse problem. | ||
| 700 | 1 | |a Brivio, Davide |e VerfasserIn |0 (DE-588)1211680401 |0 (DE-627)1700312847 |4 aut | |
| 700 | 1 | |a Sajo, Erno |e VerfasserIn |4 aut | |
| 700 | 1 | |a Hesser, Jürgen |d 1964- |e VerfasserIn |0 (DE-588)1020647353 |0 (DE-627)691291071 |0 (DE-576)361513739 |4 aut | |
| 700 | 1 | |a Zygmanski, Piotr |e VerfasserIn |0 (DE-588)1359289801 |0 (DE-627)1919398309 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physics in medicine and biology |d Bristol : IOP Publ., 1956 |g 67(2022), 5, Artikel-ID 055004, Seite 1-18 |h Online-Ressource |w (DE-627)269016163 |w (DE-600)1473501-5 |w (DE-576)088704130 |x 1361-6560 |7 nnas |a Remote sensing array (RSA) for linac beam monitoring |
| 773 | 1 | 8 | |g volume:67 |g year:2022 |g number:5 |g elocationid:055004 |g pages:1-18 |g extent:18 |a Remote sensing array (RSA) for linac beam monitoring |
| 856 | 4 | 0 | |u https://doi.org/10.1088/1361-6560/ac530d |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220428 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 1020647353 |a Hesser, Jürgen |m 1020647353:Hesser, Jürgen |d 60000 |d 65200 |e 60000PH1020647353 |e 65200PH1020647353 |k 0/60000/ |k 1/60000/65200/ |p 4 | ||
| 999 | |a KXP-PPN1800509227 |e 4125374716 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"recId":"1800509227","name":{"displayForm":["Robert Lauber, Davide Brivio, Erno Sajo, Jürgen Hesser and Piotr Zygmanski"]},"physDesc":[{"extent":"18 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["1.1956 -"],"recId":"269016163","id":{"issn":["1361-6560"],"eki":["269016163"],"zdb":["1473501-5"]},"disp":"Remote sensing array (RSA) for linac beam monitoringPhysics in medicine and biology","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"origin":[{"publisherPlace":"Bristol","dateIssuedDisp":"1956-","publisher":"IOP Publ.","dateIssuedKey":"1956"}],"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology"}],"part":{"text":"67(2022), 5, Artikel-ID 055004, Seite 1-18","pages":"1-18","year":"2022","volume":"67","extent":"18","issue":"5"},"language":["eng"]}],"id":{"doi":["10.1088/1361-6560/ac530d"],"eki":["1800509227"]},"person":[{"role":"aut","given":"Robert","display":"Lauber, Robert","family":"Lauber"},{"role":"aut","given":"Davide","family":"Brivio","display":"Brivio, Davide"},{"role":"aut","given":"Erno","family":"Sajo","display":"Sajo, Erno"},{"role":"aut","given":"Jürgen","family":"Hesser","display":"Hesser, Jürgen"},{"given":"Piotr","role":"aut","display":"Zygmanski, Piotr","family":"Zygmanski"}],"language":["eng"],"title":[{"title":"Remote sensing array (RSA) for linac beam monitoring","title_sort":"Remote sensing array (RSA) for linac beam monitoring"}],"note":["Gesehen am 28.04.2022"],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"24 February 2022"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} | ||
| SRT | |a LAUBERROBEREMOTESENS2420 | ||