The primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditions

Aims - - The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. - - Methods - - Single and twin pegs...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Eckert, Johannes A. (VerfasserIn) , Bitsch, Rudi G. (VerfasserIn) , Sonntag, Robert (VerfasserIn) , Reiner, Tobias (VerfasserIn) , Schwarze, Martin (VerfasserIn) , Jäger, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 7 Feb 2022
In: Bone & joint research
Year: 2022, Jahrgang: 11, Heft: 2, Pages: 82-90
ISSN:2046-3758
DOI:10.1302/2046-3758.112.BJR-2020-0507.R2
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1302/2046-3758.112.BJR-2020-0507.R2
Verlag, lizenzpflichtig, Volltext: https://online.boneandjoint.org.uk/doi/full/10.1302/2046-3758.112.BJR-2020-0507.R2
Volltext
Verfasserangaben:J.A. Eckert, R.G. Bitsch, R. Sonntag, T. Reiner, M. Schwarze, S. Jaeger

MARC

LEADER 00000caa a2200000 c 4500
001 1800766130
003 DE-627
005 20240416193415.0
007 cr uuu---uuuuu
008 220503s2022 xx |||||o 00| ||eng c
024 7 |a 10.1302/2046-3758.112.BJR-2020-0507.R2  |2 doi 
035 |a (DE-627)1800766130 
035 |a (DE-599)KXP1800766130 
035 |a (OCoLC)1341459267 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Eckert, Johannes A.  |d 1985-  |e VerfasserIn  |0 (DE-588)1116642697  |0 (DE-627)870604651  |0 (DE-576)478553854  |4 aut 
245 1 4 |a The primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditions  |c J.A. Eckert, R.G. Bitsch, R. Sonntag, T. Reiner, M. Schwarze, S. Jaeger 
264 1 |c 7 Feb 2022 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.05.2022 
520 |a Aims - - The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. - - Methods - - Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. - - Results - - At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. - - Conclusion - - Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. - - Cite this article: Bone Joint Res 2022;11(2):82-90. 
650 4 |a bone defects 
650 4 |a femora 
650 4 |a femoral component 
650 4 |a flexion 
650 4 |a hip 
650 4 |a knee flexion 
650 4 |a knees 
650 4 |a Oxford unicompartmental knee arthroplasty 
650 4 |a posterior condyle 
650 4 |a Single peg 
650 4 |a standard deviation 
650 4 |a Twin peg 
700 1 |a Bitsch, Rudi G.  |d 1970-  |e VerfasserIn  |0 (DE-588)131490060  |0 (DE-627)50981378X  |0 (DE-576)298541726  |4 aut 
700 1 |a Sonntag, Robert  |e VerfasserIn  |0 (DE-588)1068843756  |0 (DE-627)82081699X  |0 (DE-576)428211135  |4 aut 
700 1 |a Reiner, Tobias  |d 1982-  |e VerfasserIn  |0 (DE-588)1038723787  |0 (DE-627)766370356  |0 (DE-576)392759853  |4 aut 
700 1 |a Schwarze, Martin  |d 1986-  |e VerfasserIn  |0 (DE-588)1081740426  |0 (DE-627)846708663  |0 (DE-576)45474482X  |4 aut 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
773 0 8 |i Enthalten in  |t Bone & joint research  |d London : British Editorial Soc. of Bone & Joint Surgery, 2012  |g 11(2022), 2, Seite 82-90  |h Online-Ressource  |w (DE-627)718834534  |w (DE-600)2669244-2  |w (DE-576)367701073  |x 2046-3758  |7 nnas  |a The primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditions 
773 1 8 |g volume:11  |g year:2022  |g number:2  |g pages:82-90  |g extent:9  |a The primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditions 
856 4 0 |u https://doi.org/10.1302/2046-3758.112.BJR-2020-0507.R2  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://online.boneandjoint.org.uk/doi/full/10.1302/2046-3758.112.BJR-2020-0507.R2  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220503 
993 |a Article 
994 |a 2022 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 6  |y j 
998 |g 1081740426  |a Schwarze, Martin  |m 1081740426:Schwarze, Martin  |d 50000  |e 50000PS1081740426  |k 0/50000/  |p 5 
998 |g 1038723787  |a Reiner, Tobias  |m 1038723787:Reiner, Tobias  |d 910000  |d 911460  |e 910000PR1038723787  |e 911460PR1038723787  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 1068843756  |a Sonntag, Robert  |m 1068843756:Sonntag, Robert  |d 910000  |d 911460  |d 50000  |e 910000PS1068843756  |e 911460PS1068843756  |e 50000PS1068843756  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 3 
998 |g 131490060  |a Bitsch, Rudi G.  |m 131490060:Bitsch, Rudi G.  |d 50000  |e 50000PB131490060  |k 0/50000/  |p 2 
998 |g 1116642697  |a Eckert, Johannes A.  |m 1116642697:Eckert, Johannes A.  |d 910000  |d 911460  |e 910000PE1116642697  |e 911460PE1116642697  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1800766130  |e 4128577995 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"family":"Eckert","display":"Eckert, Johannes A.","given":"Johannes A.","role":"aut"},{"role":"aut","given":"Rudi G.","family":"Bitsch","display":"Bitsch, Rudi G."},{"given":"Robert","role":"aut","display":"Sonntag, Robert","family":"Sonntag"},{"family":"Reiner","display":"Reiner, Tobias","role":"aut","given":"Tobias"},{"display":"Schwarze, Martin","family":"Schwarze","role":"aut","given":"Martin"},{"role":"aut","given":"Sebastian","display":"Jäger, Sebastian","family":"Jäger"}],"name":{"displayForm":["J.A. Eckert, R.G. Bitsch, R. Sonntag, T. Reiner, M. Schwarze, S. Jaeger"]},"physDesc":[{"extent":"9 S."}],"recId":"1800766130","relHost":[{"language":["eng"],"part":{"issue":"2","text":"11(2022), 2, Seite 82-90","year":"2022","pages":"82-90","extent":"9","volume":"11"},"titleAlt":[{"title":"Bone and joint research"}],"recId":"718834534","physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["2046-3758"],"zdb":["2669244-2"],"eki":["718834534"]},"origin":[{"publisherPlace":"London","dateIssuedKey":"2012","publisher":"British Editorial Soc. of Bone & Joint Surgery","dateIssuedDisp":"2012-"}],"pubHistory":["1.2012 -"],"note":["Gesehen am 09.03.2018"],"title":[{"title_sort":"Bone & joint research","title":"Bone & joint research"}],"disp":"The primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditionsBone & joint research","type":{"media":"Online-Ressource","bibl":"periodical"}}],"id":{"doi":["10.1302/2046-3758.112.BJR-2020-0507.R2"],"eki":["1800766130"]},"note":["Gesehen am 03.05.2022"],"origin":[{"dateIssuedDisp":"7 Feb 2022","dateIssuedKey":"2022"}],"title":[{"title_sort":"primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditions","title":"The primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditions"}],"type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a ECKERTJOHAPRIMARYSTA7202