Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones

The immuno-inflammatory responses to stainless-steel (21 implants in 20 patients) and titanium plates (22 implants in 20 patients) used in the treatment of long bone fractures were studied immunohistochemically. All fractures healed without complications. In the soft tissue adjacent to the surface o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Voggenreiter, Gregor (VerfasserIn) , Leiting, Stephan (VerfasserIn) , Brauer, Holger (VerfasserIn) , Leiting, Peter (VerfasserIn) , Majetschak, Matthias (VerfasserIn) , Bardenheuer, Mark Johannes (VerfasserIn) , Obertacke, Udo (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 20 September 2002
In: Biomaterials
Year: 2003, Jahrgang: 24, Heft: 2, Pages: 247-254
ISSN:1878-5905
DOI:10.1016/S0142-9612(02)00312-5
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1016/S0142-9612(02)00312-5
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0142961202003125
Volltext
Verfasserangaben:Gregor Voggenreiter, Stefan Leiting, Holger Brauer, Peter Leiting, Matthias Majetschak, Mark Bardenheuer, Udo Obertacke

MARC

LEADER 00000caa a2200000 c 4500
001 1801041121
003 DE-627
005 20220820175002.0
007 cr uuu---uuuuu
008 220505s2003 xx |||||o 00| ||eng c
024 7 |a 10.1016/S0142-9612(02)00312-5  |2 doi 
035 |a (DE-627)1801041121 
035 |a (DE-599)KXP1801041121 
035 |a (OCoLC)1341459469 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Voggenreiter, Gregor  |d 1966-  |e VerfasserIn  |0 (DE-588)113372434  |0 (DE-627)39470231X  |0 (DE-576)170664686  |4 aut 
245 1 0 |a Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones  |c Gregor Voggenreiter, Stefan Leiting, Holger Brauer, Peter Leiting, Matthias Majetschak, Mark Bardenheuer, Udo Obertacke 
264 1 |c 20 September 2002 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.05.2022 
520 |a The immuno-inflammatory responses to stainless-steel (21 implants in 20 patients) and titanium plates (22 implants in 20 patients) used in the treatment of long bone fractures were studied immunohistochemically. All fractures healed without complications. In the soft tissue adjacent to the surface of the implants a dark discolouration of the tissue was visible in 18/21 stainless-steel and 20/22 titanium plates. Tissue specimens of all patients contained positive staining for macrophages (CD68-positive cells). Serial sections showed that the majority of cells were found to express the HLA-DR molecule indicating their activation. Many of the macrophages were surrounded by clusters of T-lymphocytes (CD3-positive cells). 17 out of 21 steel specimens and 15 out of 22 titanium specimens showed the infiltration of moderate amounts of cytotoxic T-lymphocytes (CD8-positive cells). Moderate amounts of B-lymphocytes (CD79α positive cells) were evident in four patients with steel and six patients with titanium implants. The results of the present study clearly demonstrate the presence of a marked inflammation and tissue reaction in the soft tissue covering stainless-steel and titanium plates used for internal fixation of fractures of long bones independently from the material used. 
650 4 |a Immunohistochemistry 
650 4 |a Internal fixation 
650 4 |a Long bones 
650 4 |a Stainless steel 
650 4 |a Tissue reaction 
650 4 |a Titanium 
700 1 |a Leiting, Stephan  |d 1976-  |e VerfasserIn  |0 (DE-588)129437697  |0 (DE-627)396457053  |0 (DE-576)297660268  |4 aut 
700 1 |a Brauer, Holger  |e VerfasserIn  |4 aut 
700 1 |a Leiting, Peter  |d 1940-  |e VerfasserIn  |0 (DE-588)114579016X  |0 (DE-627)100573352X  |0 (DE-576)17044936X  |4 aut 
700 1 |a Majetschak, Matthias  |d 1965-  |e VerfasserIn  |0 (DE-588)172947154  |0 (DE-627)697873919  |0 (DE-576)133801160  |4 aut 
700 1 |a Bardenheuer, Mark Johannes  |d 1964-  |e VerfasserIn  |0 (DE-588)172566673  |0 (DE-627)697502171  |0 (DE-576)133426459  |4 aut 
700 1 |a Obertacke, Udo  |d 1957-  |e VerfasserIn  |0 (DE-588)1034338978  |0 (DE-627)745232590  |0 (DE-576)381955672  |4 aut 
773 0 8 |i Enthalten in  |t Biomaterials  |d Amsterdam [u.a.] : Elsevier Science, 1980  |g 24(2003), 2, Seite 247-254  |h Online-Ressource  |w (DE-627)32043320X  |w (DE-600)2004010-6  |w (DE-576)098614932  |x 1878-5905  |7 nnas  |a Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones 
773 1 8 |g volume:24  |g year:2003  |g number:2  |g pages:247-254  |g extent:8  |a Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones 
856 4 0 |u https://dx.doi.org/10.1016/S0142-9612(02)00312-5  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0142961202003125  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220505 
993 |a Article 
994 |a 2003 
998 |g 1034338978  |a Obertacke, Udo  |m 1034338978:Obertacke, Udo  |d 60000  |d 62400  |e 60000PO1034338978  |e 62400PO1034338978  |k 0/60000/  |k 1/60000/62400/  |p 7  |y j 
998 |g 172566673  |a Bardenheuer, Mark  |m 172566673:Bardenheuer, Mark  |d 60000  |d 62400  |e 60000PB172566673  |e 62400PB172566673  |k 0/60000/  |k 1/60000/62400/  |p 6 
998 |g 172947154  |a Majetschak, Matthias  |m 172947154:Majetschak, Matthias  |d 60000  |d 62400  |e 60000PM172947154  |e 62400PM172947154  |k 0/60000/  |k 1/60000/62400/  |p 5 
998 |g 129437697  |a Leiting, Stephan  |m 129437697:Leiting, Stephan  |d 60000  |d 62400  |e 60000PL129437697  |e 62400PL129437697  |k 0/60000/  |k 1/60000/62400/  |p 2 
998 |g 113372434  |a Voggenreiter, Gregor  |m 113372434:Voggenreiter, Gregor  |d 60000  |d 62400  |d 60000  |e 60000PV113372434  |e 62400PV113372434  |e 60000PV113372434  |k 0/60000/  |k 1/60000/62400/  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1801041121  |e 4129590561 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"recId":"1801041121","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 05.05.2022"],"person":[{"role":"aut","display":"Voggenreiter, Gregor","roleDisplay":"VerfasserIn","given":"Gregor","family":"Voggenreiter"},{"given":"Stephan","family":"Leiting","role":"aut","roleDisplay":"VerfasserIn","display":"Leiting, Stephan"},{"given":"Holger","family":"Brauer","role":"aut","roleDisplay":"VerfasserIn","display":"Brauer, Holger"},{"family":"Leiting","given":"Peter","display":"Leiting, Peter","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Majetschak, Matthias","given":"Matthias","family":"Majetschak"},{"display":"Bardenheuer, Mark Johannes","roleDisplay":"VerfasserIn","role":"aut","family":"Bardenheuer","given":"Mark Johannes"},{"family":"Obertacke","given":"Udo","roleDisplay":"VerfasserIn","display":"Obertacke, Udo","role":"aut"}],"title":[{"title":"Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones","title_sort":"Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones"}],"relHost":[{"id":{"issn":["1878-5905"],"eki":["32043320X"],"zdb":["2004010-6"]},"title":[{"title_sort":"Biomaterials","title":"Biomaterials","subtitle":"biomaterials reviews online"}],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1980","dateIssuedDisp":"1980-","publisherPlace":"Amsterdam [u.a.]"}],"recId":"32043320X","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bonesBiomaterials","physDesc":[{"extent":"Online-Ressource"}],"part":{"issue":"2","pages":"247-254","year":"2003","extent":"8","text":"24(2003), 2, Seite 247-254","volume":"24"},"pubHistory":["1.1980-volume 35, issue 38 (December 2014) ; volume 36 (January 2015)-"]}],"physDesc":[{"extent":"8 S."}],"name":{"displayForm":["Gregor Voggenreiter, Stefan Leiting, Holger Brauer, Peter Leiting, Matthias Majetschak, Mark Bardenheuer, Udo Obertacke"]},"id":{"doi":["10.1016/S0142-9612(02)00312-5"],"eki":["1801041121"]},"origin":[{"dateIssuedDisp":"20 September 2002","dateIssuedKey":"2003"}]} 
SRT |a VOGGENREITIMMUNOINFL2020