Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty

In the present work, the influence of the trunnion surface topography and the near-surface residual stresses on the joining process of a taper connection is examined using a replicate of the realistic taper connection as it occurs in conventional hip joint implants. The focus of the work is on the s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mai, Phuong Thao (VerfasserIn) , Bormann, Therese (VerfasserIn) , Müller, Ulrike (VerfasserIn) , Kretzer, Jan Philippe (VerfasserIn) , Gibmeier, Jens (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 4 February 2022
In: Journal of the mechanical behavior of biomedical materials
Year: 2022, Jahrgang: 128, Pages: 1-11
ISSN:1878-0180
DOI:10.1016/j.jmbbm.2022.105119
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jmbbm.2022.105119
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1751616122000455
Volltext
Verfasserangaben:Phuong Thao Mai, Therese Bormann, Ulrike Müller, Jan Philippe Kretzer, Jens Gibmeier

MARC

LEADER 00000caa a2200000 c 4500
001 1801373337
003 DE-627
005 20240416193446.0
007 cr uuu---uuuuu
008 220511s2022 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jmbbm.2022.105119  |2 doi 
035 |a (DE-627)1801373337 
035 |a (DE-599)KXP1801373337 
035 |a (OCoLC)1341459845 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mai, Phuong Thao  |e VerfasserIn  |0 (DE-588)1257271776  |0 (DE-627)1801400016  |4 aut 
245 1 0 |a Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty  |c Phuong Thao Mai, Therese Bormann, Ulrike Müller, Jan Philippe Kretzer, Jens Gibmeier 
264 1 |c 4 February 2022 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.05.2022 
520 |a In the present work, the influence of the trunnion surface topography and the near-surface residual stresses on the joining process of a taper connection is examined using a replicate of the realistic taper connection as it occurs in conventional hip joint implants. The focus of the work is on the surface of the taper trunnion made of Ti6Al4V ELI and its effect on the connection stability with a CoCrMo counterpart. In this regard, the interrelation between surface topography, residual stresses, the joining behavior and the corrosion behavior under dynamic loading have been systematically investigated. For this purpose, taper trunnions produced by means of three different machining processes were considered, i.e. fine machining, rough machining and a novel furrowing process. These mechanical surface treatments result in different surface topographies and near-surface work hardening and residual stress states. The results show that the primary taper stability is hardly altered by the different types of trunnion surfaces. For all three surface states, the joining/dismantling procedure did not change the residual stress state at the surface. After corrosion testing under dynamic loading, the fine machined taper surface exhibits the highest stability. Moreover, fine machined tapers consolidated during the dynamic corrosion experiment as the ratio between joining and dismantling force increased from 0.49 ± 0.04 to 0.83 ± 0.08. For the furrowed and rough machined taper surfaces, the connection stability showed a tendency towards increase and decrease, respectively, in the course of dynamic corrosion testing. The results indicate that for choosing an optimal taper trunnion surface, the effects of corrosion must be taken into account. 
650 4 |a Fretting fatigue 
650 4 |a Head-stem junction 
650 4 |a Joining process 
650 4 |a Taper contact situation 
650 4 |a Topography 
650 4 |a Total hip arthroplasty 
700 1 |a Bormann, Therese  |e VerfasserIn  |0 (DE-588)1205894829  |0 (DE-627)1691740136  |4 aut 
700 1 |a Müller, Ulrike  |d 1988-  |e VerfasserIn  |0 (DE-588)1116644002  |0 (DE-627)870607081  |0 (DE-576)478555504  |4 aut 
700 1 |a Kretzer, Jan Philippe  |d 1978-  |e VerfasserIn  |0 (DE-588)136998348  |0 (DE-627)589003690  |0 (DE-576)301383103  |4 aut 
700 1 |a Gibmeier, Jens  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of the mechanical behavior of biomedical materials  |d Amsterdam [u.a.] : Elsevier, 2008  |g 128(2022), Artikel-ID 105119, Seite 1-11  |h Online-Ressource  |w (DE-627)538216727  |w (DE-600)2378381-3  |w (DE-576)271586761  |x 1878-0180  |7 nnas  |a Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty 
773 1 8 |g volume:128  |g year:2022  |g elocationid:105119  |g pages:1-11  |g extent:11  |a Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty 
856 4 0 |u https://doi.org/10.1016/j.jmbbm.2022.105119  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1751616122000455  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220511 
993 |a Article 
994 |a 2022 
998 |g 136998348  |a Kretzer, Jan Philippe  |m 136998348:Kretzer, Jan Philippe  |d 910000  |d 911460  |d 50000  |e 910000PK136998348  |e 911460PK136998348  |e 50000PK136998348  |k 0/910000/  |k 1/910000/911460/  |k 0/50000/  |p 4 
998 |g 1116644002  |a Müller, Ulrike  |m 1116644002:Müller, Ulrike  |p 3 
998 |g 1205894829  |a Bormann, Therese  |m 1205894829:Bormann, Therese  |d 910000  |d 911460  |e 910000PB1205894829  |e 911460PB1205894829  |k 0/910000/  |k 1/910000/911460/  |p 2 
999 |a KXP-PPN1801373337  |e 4131849895 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"title_sort":"Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty","title":"Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty"}],"recId":"1801373337","origin":[{"dateIssuedDisp":"4 February 2022","dateIssuedKey":"2022"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2378381-3"],"issn":["1878-0180"],"eki":["538216727"]},"disp":"Effect of surface topography and residual stress on the taper connection stability in total hip arthroplastyJournal of the mechanical behavior of biomedical materials","note":["Gesehen am 22.09.2021"],"recId":"538216727","origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"2008","publisher":"Elsevier","dateIssuedDisp":"2008-"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.2008 - 4.2011; Vol. 5.2012 -"],"title":[{"title":"Journal of the mechanical behavior of biomedical materials","title_sort":"Journal of the mechanical behavior of biomedical materials"}],"part":{"volume":"128","year":"2022","text":"128(2022), Artikel-ID 105119, Seite 1-11","extent":"11","pages":"1-11"},"language":["eng"]}],"note":["Gesehen am 11.05.2022"],"physDesc":[{"extent":"11 S."}],"id":{"doi":["10.1016/j.jmbbm.2022.105119"],"eki":["1801373337"]},"name":{"displayForm":["Phuong Thao Mai, Therese Bormann, Ulrike Müller, Jan Philippe Kretzer, Jens Gibmeier"]},"person":[{"family":"Mai","given":"Phuong Thao","role":"aut","display":"Mai, Phuong Thao"},{"display":"Bormann, Therese","role":"aut","given":"Therese","family":"Bormann"},{"family":"Müller","given":"Ulrike","role":"aut","display":"Müller, Ulrike"},{"family":"Kretzer","display":"Kretzer, Jan Philippe","given":"Jan Philippe","role":"aut"},{"display":"Gibmeier, Jens","given":"Jens","role":"aut","family":"Gibmeier"}]} 
SRT |a MAIPHUONGTEFFECTOFSU4202