Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty
In the present work, the influence of the trunnion surface topography and the near-surface residual stresses on the joining process of a taper connection is examined using a replicate of the realistic taper connection as it occurs in conventional hip joint implants. The focus of the work is on the s...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
4 February 2022
|
| In: |
Journal of the mechanical behavior of biomedical materials
Year: 2022, Jahrgang: 128, Pages: 1-11 |
| ISSN: | 1878-0180 |
| DOI: | 10.1016/j.jmbbm.2022.105119 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jmbbm.2022.105119 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1751616122000455 |
| Verfasserangaben: | Phuong Thao Mai, Therese Bormann, Ulrike Müller, Jan Philippe Kretzer, Jens Gibmeier |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1801373337 | ||
| 003 | DE-627 | ||
| 005 | 20240416193446.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220511s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jmbbm.2022.105119 |2 doi | |
| 035 | |a (DE-627)1801373337 | ||
| 035 | |a (DE-599)KXP1801373337 | ||
| 035 | |a (OCoLC)1341459845 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Mai, Phuong Thao |e VerfasserIn |0 (DE-588)1257271776 |0 (DE-627)1801400016 |4 aut | |
| 245 | 1 | 0 | |a Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty |c Phuong Thao Mai, Therese Bormann, Ulrike Müller, Jan Philippe Kretzer, Jens Gibmeier |
| 264 | 1 | |c 4 February 2022 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 11.05.2022 | ||
| 520 | |a In the present work, the influence of the trunnion surface topography and the near-surface residual stresses on the joining process of a taper connection is examined using a replicate of the realistic taper connection as it occurs in conventional hip joint implants. The focus of the work is on the surface of the taper trunnion made of Ti6Al4V ELI and its effect on the connection stability with a CoCrMo counterpart. In this regard, the interrelation between surface topography, residual stresses, the joining behavior and the corrosion behavior under dynamic loading have been systematically investigated. For this purpose, taper trunnions produced by means of three different machining processes were considered, i.e. fine machining, rough machining and a novel furrowing process. These mechanical surface treatments result in different surface topographies and near-surface work hardening and residual stress states. The results show that the primary taper stability is hardly altered by the different types of trunnion surfaces. For all three surface states, the joining/dismantling procedure did not change the residual stress state at the surface. After corrosion testing under dynamic loading, the fine machined taper surface exhibits the highest stability. Moreover, fine machined tapers consolidated during the dynamic corrosion experiment as the ratio between joining and dismantling force increased from 0.49 ± 0.04 to 0.83 ± 0.08. For the furrowed and rough machined taper surfaces, the connection stability showed a tendency towards increase and decrease, respectively, in the course of dynamic corrosion testing. The results indicate that for choosing an optimal taper trunnion surface, the effects of corrosion must be taken into account. | ||
| 650 | 4 | |a Fretting fatigue | |
| 650 | 4 | |a Head-stem junction | |
| 650 | 4 | |a Joining process | |
| 650 | 4 | |a Taper contact situation | |
| 650 | 4 | |a Topography | |
| 650 | 4 | |a Total hip arthroplasty | |
| 700 | 1 | |a Bormann, Therese |e VerfasserIn |0 (DE-588)1205894829 |0 (DE-627)1691740136 |4 aut | |
| 700 | 1 | |a Müller, Ulrike |d 1988- |e VerfasserIn |0 (DE-588)1116644002 |0 (DE-627)870607081 |0 (DE-576)478555504 |4 aut | |
| 700 | 1 | |a Kretzer, Jan Philippe |d 1978- |e VerfasserIn |0 (DE-588)136998348 |0 (DE-627)589003690 |0 (DE-576)301383103 |4 aut | |
| 700 | 1 | |a Gibmeier, Jens |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of the mechanical behavior of biomedical materials |d Amsterdam [u.a.] : Elsevier, 2008 |g 128(2022), Artikel-ID 105119, Seite 1-11 |h Online-Ressource |w (DE-627)538216727 |w (DE-600)2378381-3 |w (DE-576)271586761 |x 1878-0180 |7 nnas |a Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty |
| 773 | 1 | 8 | |g volume:128 |g year:2022 |g elocationid:105119 |g pages:1-11 |g extent:11 |a Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jmbbm.2022.105119 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S1751616122000455 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220511 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 136998348 |a Kretzer, Jan Philippe |m 136998348:Kretzer, Jan Philippe |d 910000 |d 911460 |d 50000 |e 910000PK136998348 |e 911460PK136998348 |e 50000PK136998348 |k 0/910000/ |k 1/910000/911460/ |k 0/50000/ |p 4 | ||
| 998 | |g 1116644002 |a Müller, Ulrike |m 1116644002:Müller, Ulrike |p 3 | ||
| 998 | |g 1205894829 |a Bormann, Therese |m 1205894829:Bormann, Therese |d 910000 |d 911460 |e 910000PB1205894829 |e 911460PB1205894829 |k 0/910000/ |k 1/910000/911460/ |p 2 | ||
| 999 | |a KXP-PPN1801373337 |e 4131849895 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"title":[{"title_sort":"Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty","title":"Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty"}],"recId":"1801373337","origin":[{"dateIssuedDisp":"4 February 2022","dateIssuedKey":"2022"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2378381-3"],"issn":["1878-0180"],"eki":["538216727"]},"disp":"Effect of surface topography and residual stress on the taper connection stability in total hip arthroplastyJournal of the mechanical behavior of biomedical materials","note":["Gesehen am 22.09.2021"],"recId":"538216727","origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"2008","publisher":"Elsevier","dateIssuedDisp":"2008-"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.2008 - 4.2011; Vol. 5.2012 -"],"title":[{"title":"Journal of the mechanical behavior of biomedical materials","title_sort":"Journal of the mechanical behavior of biomedical materials"}],"part":{"volume":"128","year":"2022","text":"128(2022), Artikel-ID 105119, Seite 1-11","extent":"11","pages":"1-11"},"language":["eng"]}],"note":["Gesehen am 11.05.2022"],"physDesc":[{"extent":"11 S."}],"id":{"doi":["10.1016/j.jmbbm.2022.105119"],"eki":["1801373337"]},"name":{"displayForm":["Phuong Thao Mai, Therese Bormann, Ulrike Müller, Jan Philippe Kretzer, Jens Gibmeier"]},"person":[{"family":"Mai","given":"Phuong Thao","role":"aut","display":"Mai, Phuong Thao"},{"display":"Bormann, Therese","role":"aut","given":"Therese","family":"Bormann"},{"family":"Müller","given":"Ulrike","role":"aut","display":"Müller, Ulrike"},{"family":"Kretzer","display":"Kretzer, Jan Philippe","given":"Jan Philippe","role":"aut"},{"display":"Gibmeier, Jens","given":"Jens","role":"aut","family":"Gibmeier"}]} | ||
| SRT | |a MAIPHUONGTEFFECTOFSU4202 | ||