End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom

Objective. In MR-guided radiotherapy (MRgRT) for prostate cancer treatments inter-fractional anatomy changes such as bladder and rectum fillings may be corrected by an online adaption of the treatment plan. To clinically implement such complex treatment procedures, however, specific end-to-end tests...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Elter, Alina (VerfasserIn) , Rippke, Carolin (VerfasserIn) , Johnen, Wibke (VerfasserIn) , Mann, Philipp (VerfasserIn) , Hellwich, E. (VerfasserIn) , Schwahofer, Andrea (VerfasserIn) , Dorsch, Stefan (VerfasserIn) , Buchele, Carolin (VerfasserIn) , Klüter, Sebastian (VerfasserIn) , Karger, Christian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 16 December 2021
In: Physics in medicine and biology
Year: 2021, Jahrgang: 66, Heft: 24, Pages: 1-12
ISSN:1361-6560
DOI:10.1088/1361-6560/ac3e0c
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/ac3e0c
Volltext
Verfasserangaben:A. Elter, C. Rippke, W. Johnen, P. Mann, E. Hellwich, A. Schwahofer, S. Dorsch, C. Buchele, S. Klüter and C. P. Karger

MARC

LEADER 00000caa a2200000 c 4500
001 180530187X
003 DE-627
005 20230428181706.0
007 cr uuu---uuuuu
008 220531s2021 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/ac3e0c  |2 doi 
035 |a (DE-627)180530187X 
035 |a (DE-599)KXP180530187X 
035 |a (OCoLC)1341460541 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Elter, Alina  |d 1994-  |e VerfasserIn  |0 (DE-588)1199970298  |0 (DE-627)1682114309  |4 aut 
245 1 0 |a End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom  |c A. Elter, C. Rippke, W. Johnen, P. Mann, E. Hellwich, A. Schwahofer, S. Dorsch, C. Buchele, S. Klüter and C. P. Karger 
264 1 |c 16 December 2021 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 31.05.2022 
520 |a Objective. In MR-guided radiotherapy (MRgRT) for prostate cancer treatments inter-fractional anatomy changes such as bladder and rectum fillings may be corrected by an online adaption of the treatment plan. To clinically implement such complex treatment procedures, however, specific end-to-end tests are required that are able to validate the overall accuracy of all treatment steps from pre-treatment imaging to dose delivery. Approach. In this study, an end-to-end test of a fractionated and online adapted MRgRT prostate irradiation was performed using the so-called ADAM-PETer phantom. The phantom was adapted to perform 3D polymer gel (PG) dosimetry in the prostate and rectum. Furthermore, thermoluminescence detectors (TLDs) were placed at the center and on the surface of the prostate for additional dose measurements as well as for an external dose renormalization of the PG. For the end-to-end test, a total of five online adapted irradiations were applied in sequence with different bladder and rectum fillings, respectively. Main results. A good agreement of measured and planned dose was found represented by high -index passing rates ( criterion) of the PG evaluation of in the prostate and in the rectum. TLDs used for PG renormalization at the center of the prostate showed a deviation of Significance. The presented end-to-end test, which allows for 3D dose verification in the prostate and rectum, demonstrates the feasibility and accuracy of fractionated and online-adapted prostate irradiations in presence of inter-fractional anatomy changes. Such tests are of high clinical importance for the commissioning of new image-guided treatment procedures such as online adaptive MRgRT. 
700 1 |a Rippke, Carolin  |d 1993-  |e VerfasserIn  |0 (DE-588)1238772773  |0 (DE-627)1766392539  |4 aut 
700 1 |a Johnen, Wibke  |e VerfasserIn  |0 (DE-588)1166999270  |0 (DE-627)1030846324  |0 (DE-576)510993192  |4 aut 
700 1 |a Mann, Philipp  |e VerfasserIn  |0 (DE-588)1133588158  |0 (DE-627)889511675  |0 (DE-576)489523056  |4 aut 
700 1 |a Hellwich, E.  |e VerfasserIn  |4 aut 
700 1 |a Schwahofer, Andrea  |d 1983-  |e VerfasserIn  |0 (DE-588)1124864105  |0 (DE-627)879197811  |0 (DE-576)483203645  |4 aut 
700 1 |a Dorsch, Stefan  |d 1989-  |e VerfasserIn  |0 (DE-588)1187162752  |0 (DE-627)1666316008  |4 aut 
700 1 |a Buchele, Carolin  |d 1992-  |e VerfasserIn  |0 (DE-588)1238773230  |0 (DE-627)1766395635  |4 aut 
700 1 |a Klüter, Sebastian  |d 1980-  |e VerfasserIn  |0 (DE-588)1071160796  |0 (DE-627)825622646  |0 (DE-576)311255248  |4 aut 
700 1 |a Karger, Christian  |e VerfasserIn  |0 (DE-588)1077113641  |0 (DE-627)836027280  |0 (DE-576)170866459  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 66(2021), 24, Artikel-ID 245021, Seite 1-12  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom 
773 1 8 |g volume:66  |g year:2021  |g number:24  |g elocationid:245021  |g pages:1-12  |g extent:12  |a End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom 
856 4 0 |u https://doi.org/10.1088/1361-6560/ac3e0c  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220531 
993 |a Article 
994 |a 2021 
998 |g 1077113641  |a Karger, Christian  |m 1077113641:Karger, Christian  |d 50000  |e 50000PK1077113641  |k 0/50000/  |p 10  |y j 
998 |g 1071160796  |a Klüter, Sebastian  |m 1071160796:Klüter, Sebastian  |d 910000  |d 911400  |e 910000PK1071160796  |e 911400PK1071160796  |k 0/910000/  |k 1/910000/911400/  |p 9 
998 |g 1238773230  |a Buchele, Carolin  |m 1238773230:Buchele, Carolin  |d 910000  |d 911400  |e 910000PB1238773230  |e 911400PB1238773230  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 1166999270  |a Johnen, Wibke  |m 1166999270:Johnen, Wibke 
998 |g 1238772773  |a Rippke, Carolin  |m 1238772773:Rippke, Carolin  |d 910000  |d 911400  |e 910000PR1238772773  |e 911400PR1238772773  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1199970298  |a Elter, Alina  |m 1199970298:Elter, Alina  |d 130000  |e 130000PE1199970298  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN180530187X  |e 4141663719 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"display":"Elter, Alina","given":"Alina","role":"aut","family":"Elter"},{"family":"Rippke","given":"Carolin","role":"aut","display":"Rippke, Carolin"},{"display":"Johnen, Wibke","role":"aut","given":"Wibke","family":"Johnen"},{"family":"Mann","given":"Philipp","role":"aut","display":"Mann, Philipp"},{"family":"Hellwich","role":"aut","given":"E.","display":"Hellwich, E."},{"role":"aut","given":"Andrea","family":"Schwahofer","display":"Schwahofer, Andrea"},{"given":"Stefan","role":"aut","family":"Dorsch","display":"Dorsch, Stefan"},{"family":"Buchele","given":"Carolin","role":"aut","display":"Buchele, Carolin"},{"family":"Klüter","role":"aut","given":"Sebastian","display":"Klüter, Sebastian"},{"display":"Karger, Christian","family":"Karger","role":"aut","given":"Christian"}],"title":[{"title":"End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom","title_sort":"End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"physDesc":[{"extent":"12 S."}],"id":{"eki":["180530187X"],"doi":["10.1088/1361-6560/ac3e0c"]},"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"16 December 2021"}],"name":{"displayForm":["A. Elter, C. Rippke, W. Johnen, P. Mann, E. Hellwich, A. Schwahofer, S. Dorsch, C. Buchele, S. Klüter and C. P. Karger"]},"recId":"180530187X","note":["Gesehen am 31.05.2022"],"relHost":[{"part":{"extent":"12","text":"66(2021), 24, Artikel-ID 245021, Seite 1-12","pages":"1-12","volume":"66","year":"2021","issue":"24"},"origin":[{"publisherPlace":"Bristol","dateIssuedDisp":"1956-","publisher":"IOP Publ.","dateIssuedKey":"1956"}],"id":{"eki":["269016163"],"zdb":["1473501-5"],"issn":["1361-6560"]},"disp":"End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantomPhysics in medicine and biology","recId":"269016163","title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology","title_sort":"Physics in medicine and biology"}],"pubHistory":["1.1956 -"],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"type":{"bibl":"periodical","media":"Online-Ressource"}}]} 
SRT |a ELTERALINAENDTOENDTE1620