Validation of a new equinometer device for measuring ankle range of motion in patients with cerebral palsy: An observational study

The goniometer is the gold-standard measurement tool of ankle range of motion (ROM). However, several studies have questioned its inter- and intra-rater reliability. Therefore, we conducted this validation study to assess the reliability of a different tool, named Equinometer, as a measurement devic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Horsch, Axel (VerfasserIn) , Kleiber, Saskia (VerfasserIn) , Ghandour, Maher (VerfasserIn) , Klotz, Matthias C. M. (VerfasserIn) , Hetto, Pit (VerfasserIn) , Tsitlakidis, Stefanos (VerfasserIn) , Alimusaj, Merkur (VerfasserIn) , Götze, Marco (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2022
In: Medicine
Year: 2022, Jahrgang: 101, Heft: 17, Pages: 1-9
ISSN:1536-5964
DOI:10.1097/MD.0000000000029230
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1097/MD.0000000000029230
Verlag, kostenfrei, Volltext: https://journals.lww.com/md-journal/Fulltext/2022/04290/Validation_of_a_new_Equinometer_device_for.21.aspx
Volltext
Verfasserangaben:Axel Horsch, Saskia Kleiber, Maher Ghandour, Matthias Christoph Michael Klotz, Pit Hetto, Stefanos Tsitlakidis, Merkur Alimusaj, Marco Götze

MARC

LEADER 00000caa a2200000 c 4500
001 1808544722
003 DE-627
005 20260112160528.0
007 cr uuu---uuuuu
008 220629s2022 xx |||||o 00| ||eng c
024 7 |a 10.1097/MD.0000000000029230  |2 doi 
035 |a (DE-627)1808544722 
035 |a (DE-599)KXP1808544722 
035 |a (OCoLC)1341461953 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Horsch, Axel  |d 1985-  |e VerfasserIn  |0 (DE-588)1170262481  |0 (DE-627)1038156831  |0 (DE-576)512461066  |4 aut 
245 1 0 |a Validation of a new equinometer device for measuring ankle range of motion in patients with cerebral palsy  |b An observational study  |c Axel Horsch, Saskia Kleiber, Maher Ghandour, Matthias Christoph Michael Klotz, Pit Hetto, Stefanos Tsitlakidis, Merkur Alimusaj, Marco Götze 
264 1 |c 2022 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 29.06.2022 
520 |a The goniometer is the gold-standard measurement tool of ankle range of motion (ROM). However, several studies have questioned its inter- and intra-rater reliability. Therefore, we conducted this validation study to assess the reliability of a different tool, named Equinometer, as a measurement device of ankle ROM in addition to comparing the reproducibility of their results. - Sixteen healthy individuals were included. They underwent both goniometer and Equinometer measurements in knee extension and 90° knee flexion (Silfverskjöld Test). Three raters reported the values of dorsiflexion (DF) and plantarflexion (PF) in each session using both measurement tools. Intra-rater reliability was assessed between 2 raters on another study group of 24 participants. Intraclass correlation coefficients were used to determine the reliability of the used device. - The age of study subjects ranged from 22 to 85 years. Fifty percent were males, and the right ankle joint was the most examined side (68.75%). In terms of DF and PF during knee extension and flexion, our analysis revealed that the measurements recorded by the Equinometer were equivalent to the goniometer. Of note, the intra-rater reliability of the Equinometer was excellent for both DF and PF assessment during both knee flexion and extension (Intraclass correlation coefficient ranged from 0.90 to 0.98), with minimal mean differences from goniometer measurements. Subgroup analysis based on age did not reveal any significant differences (P > .05). - Given the high intra-rater correlations of the Equinometer, we suggest that it is reliable and precise in recording ankle ROM in outpatient clinics, particularly to obtain reproductive, comparable and unbiased data from different observers. 
700 1 |a Kleiber, Saskia  |d 1996-  |e VerfasserIn  |0 (DE-588)1386277436  |0 (DE-627)1948234106  |4 aut 
700 1 |a Ghandour, Maher  |e VerfasserIn  |0 (DE-588)1281548286  |0 (DE-627)1837208867  |4 aut 
700 1 |a Klotz, Matthias C. M.  |d 1982-  |e VerfasserIn  |0 (DE-588)1013229975  |0 (DE-627)663823897  |0 (DE-576)34673522X  |4 aut 
700 1 |a Hetto, Pit  |d 1991-  |e VerfasserIn  |0 (DE-588)1161103937  |0 (DE-627)1024490858  |0 (DE-576)506356973  |4 aut 
700 1 |a Tsitlakidis, Stefanos  |d 1990-  |e VerfasserIn  |0 (DE-588)1175990841  |0 (DE-627)1047129485  |0 (DE-576)516473794  |4 aut 
700 1 |a Alimusaj, Merkur  |e VerfasserIn  |0 (DE-588)1046144685  |0 (DE-627)775784710  |0 (DE-576)39941245X  |4 aut 
700 1 |a Götze, Marco  |d 1985-  |e VerfasserIn  |0 (DE-588)1025309936  |0 (DE-627)722025149  |0 (DE-576)370192354  |4 aut 
773 0 8 |i Enthalten in  |t Medicine  |d Baltimore, Md. : Lippincott Williams & Wilkins, 1922  |g 101(2022), 17, Artikel-ID e29230, Seite 1-9  |h Online-Ressource  |w (DE-627)330613820  |w (DE-600)2049818-4  |w (DE-576)096290811  |x 1536-5964  |7 nnas  |a Validation of a new equinometer device for measuring ankle range of motion in patients with cerebral palsy An observational study 
773 1 8 |g volume:101  |g year:2022  |g number:17  |g elocationid:e29230  |g pages:1-9  |g extent:9  |a Validation of a new equinometer device for measuring ankle range of motion in patients with cerebral palsy An observational study 
856 4 0 |u https://doi.org/10.1097/MD.0000000000029230  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext  |7 0 
856 4 0 |u https://journals.lww.com/md-journal/Fulltext/2022/04290/Validation_of_a_new_Equinometer_device_for.21.aspx  |x Verlag  |z kostenfrei  |3 Volltext  |7 0 
951 |a AR 
992 |a 20220629 
993 |a Article 
994 |a 2022 
998 |g 1025309936  |a Götze, Marco  |m 1025309936:Götze, Marco  |d 910000  |d 911460  |e 910000PG1025309936  |e 911460PG1025309936  |k 0/910000/  |k 1/910000/911460/  |p 8  |y j 
998 |g 1046144685  |a Alimusaj, Merkur  |m 1046144685:Alimusaj, Merkur  |d 910000  |d 911460  |e 910000PA1046144685  |e 911460PA1046144685  |k 0/910000/  |k 1/910000/911460/  |p 7 
998 |g 1175990841  |a Tsitlakidis, Stefanos  |m 1175990841:Tsitlakidis, Stefanos  |d 910000  |d 911460  |e 910000PT1175990841  |e 911460PT1175990841  |k 0/910000/  |k 1/910000/911460/  |p 6 
998 |g 1161103937  |a Hetto, Pit  |m 1161103937:Hetto, Pit  |d 910000  |d 911460  |e 910000PH1161103937  |e 911460PH1161103937  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 1013229975  |a Klotz, Matthias C. M.  |m 1013229975:Klotz, Matthias C. M.  |d 50000  |e 50000PK1013229975  |k 0/50000/  |p 4 
998 |g 1386277436  |a Kleiber, Saskia  |m 1386277436:Kleiber, Saskia  |d 50000  |e 50000PK1386277436  |k 0/50000/  |p 2 
998 |g 1170262481  |a Horsch, Axel  |m 1170262481:Horsch, Axel  |d 910000  |d 911460  |e 910000PH1170262481  |e 911460PH1170262481  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1808544722  |e 4158567483 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"name":{"displayForm":["Axel Horsch, Saskia Kleiber, Maher Ghandour, Matthias Christoph Michael Klotz, Pit Hetto, Stefanos Tsitlakidis, Merkur Alimusaj, Marco Götze"]},"note":["Gesehen am 29.06.2022"],"person":[{"family":"Horsch","role":"aut","given":"Axel","display":"Horsch, Axel"},{"family":"Kleiber","role":"aut","display":"Kleiber, Saskia","given":"Saskia"},{"family":"Ghandour","role":"aut","display":"Ghandour, Maher","given":"Maher"},{"family":"Klotz","role":"aut","display":"Klotz, Matthias C. M.","given":"Matthias C. M."},{"role":"aut","family":"Hetto","given":"Pit","display":"Hetto, Pit"},{"given":"Stefanos","display":"Tsitlakidis, Stefanos","role":"aut","family":"Tsitlakidis"},{"display":"Alimusaj, Merkur","given":"Merkur","role":"aut","family":"Alimusaj"},{"role":"aut","family":"Götze","given":"Marco","display":"Götze, Marco"}],"recId":"1808544722","id":{"eki":["1808544722"],"doi":["10.1097/MD.0000000000029230"]},"physDesc":[{"extent":"9 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Validation of a new equinometer device for measuring ankle range of motion in patients with cerebral palsy","title":"Validation of a new equinometer device for measuring ankle range of motion in patients with cerebral palsy","subtitle":"An observational study"}],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"2022"}],"relHost":[{"language":["eng"],"part":{"issue":"17","pages":"1-9","extent":"9","text":"101(2022), 17, Artikel-ID e29230, Seite 1-9","volume":"101","year":"2022"},"pubHistory":["1.1922 -"],"note":["Gesehen am 26.11.20"],"disp":"Validation of a new equinometer device for measuring ankle range of motion in patients with cerebral palsy An observational studyMedicine","type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"330613820","title":[{"title_sort":"Medicine","title":"Medicine"}],"id":{"eki":["330613820"],"issn":["1536-5964"],"zdb":["2049818-4"]},"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Lippincott Williams & Wilkins","dateIssuedDisp":"1922-","dateIssuedKey":"1922","publisherPlace":"Baltimore, Md."}]}]} 
SRT |a HORSCHAXELVALIDATION2022