Corneoscleroplasty with maintenance of the angle in two cases of extensive corneoscleral disease

Purpose: We report a 2 year follow-up in two patients after corneoscleroplasty. - Method: Using lamellar corneoscleral dissection to maintain the drainage angle and its function, we performed a 14 mm allograft corneoscleroplasty in 2 eyes. For surgical treatment in both cases a 9.5 mm corneal button...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Burk, Reinhard (VerfasserIn) , Joussen, Antonia J. M. (VerfasserIn)
Dokumenttyp: Article (Journal) Konferenzschrift
Sprache:Englisch
Veröffentlicht: 01 March 2000
In: Eye
Year: 2000, Jahrgang: 14, Heft: 2, Pages: 196-200
ISSN:1476-5454
DOI:10.1038/eye.2000.53
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1038/eye.2000.53
Verlag, lizenzpflichtig, Volltext: https://www.nature.com/articles/eye200053
Volltext
Verfasserangaben:Reinhard O.W. Burk, Antonia M. Joussen

MARC

LEADER 00000caa a2200000 c 4500
001 1808670353
003 DE-627
005 20230426090943.0
007 cr uuu---uuuuu
008 220630s2000 xx |||||o 00| ||eng c
024 7 |a 10.1038/eye.2000.53  |2 doi 
035 |a (DE-627)1808670353 
035 |a (DE-599)KXP1808670353 
035 |a (OCoLC)1341463295 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Burk, Reinhard  |d 1956-  |e VerfasserIn  |0 (DE-588)110574842  |0 (DE-627)534468128  |0 (DE-576)289677343  |4 aut 
245 1 0 |a Corneoscleroplasty with maintenance of the angle in two cases of extensive corneoscleral disease  |c Reinhard O.W. Burk, Antonia M. Joussen 
264 1 |c 01 March 2000 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.06.2022 
520 |a Purpose: We report a 2 year follow-up in two patients after corneoscleroplasty. - Method: Using lamellar corneoscleral dissection to maintain the drainage angle and its function, we performed a 14 mm allograft corneoscleroplasty in 2 eyes. For surgical treatment in both cases a 9.5 mm corneal button was excised from the recipient after peritomy and scleral lamellar preparation up to 14 mm. A 14 mm donor button was inserted and held in place with multiple Prolene sutures. One eye presented with a large perforating corneal ulcer after herpetic keratitis in a patient with recurrent rheumatoid uveitis associated with rubeosis iridis. The second eye had had a penetrating keratoplasty for keratoconus 30 years previously and presented with decompensating keratoglobus. Immune suppression was performed with systemic cyclosporin A and additional steroids when required. - Results: Both patients had a clear graft at the last follow-up visit and visual acuity was improved to a best corrected visual acuity of 0.6. Intraocular pressure in the keratoglobus eye was maintained at 6 mmHg without treatment, whereas the second case required continuing treatment with systemic acetazolamide because of neovascular glaucoma. The anterior chamber angles remained open in both patients. Contact lenses were helpful in the prevention of epithelial irregularities and defects. Both patients had an episode of immunological graft reaction which was reversed by immunosuppressive treatment. Phacoemulsification with intraocular lens implantation, which was performed 2 years after transplantation in the keratoglobus eye, did not affect the graft clarity or cause rejection episodes. - Conclusion: Our results using corneoscleroplasty have been encouraging in severe destructive corneal disease. 
650 4 |a general 
650 4 |a Laboratory Medicine 
650 4 |a Medicine/Public Health 
650 4 |a Ophthalmology 
650 4 |a Pharmaceutical Sciences/Technology 
650 4 |a Surgery 
650 4 |a Surgical Oncology 
700 1 |a Joussen, Antonia J. M.  |d 1971-  |e VerfasserIn  |0 (DE-588)115413073  |0 (DE-627)691298904  |0 (DE-576)289869110  |4 aut 
773 0 8 |i Enthalten in  |t Eye  |d Basingstoke : Nature Publishing Group, 1987  |g 14(2000), 2, Seite 196-200  |h Online-Ressource  |w (DE-627)349234922  |w (DE-600)2080338-2  |w (DE-576)252074548  |x 1476-5454  |7 nnas  |a Corneoscleroplasty with maintenance of the angle in two cases of extensive corneoscleral disease 
773 1 8 |g volume:14  |g year:2000  |g number:2  |g pages:196-200  |g extent:5  |a Corneoscleroplasty with maintenance of the angle in two cases of extensive corneoscleral disease 
856 4 0 |u https://doi.org/10.1038/eye.2000.53  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.nature.com/articles/eye200053  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220630 
993 |a ConferencePaper 
994 |a 2000 
998 |g 110574842  |a Burk, Reinhard  |m 110574842:Burk, Reinhard  |d 910000  |d 910900  |e 910000PB110574842  |e 910900PB110574842  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1808670353  |e 4159170870 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1808670353","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 30.06.2022"],"title":[{"title":"Corneoscleroplasty with maintenance of the angle in two cases of extensive corneoscleral disease","title_sort":"Corneoscleroplasty with maintenance of the angle in two cases of extensive corneoscleral disease"}],"person":[{"given":"Reinhard","family":"Burk","role":"aut","roleDisplay":"VerfasserIn","display":"Burk, Reinhard"},{"roleDisplay":"VerfasserIn","display":"Joussen, Antonia J. M.","role":"aut","family":"Joussen","given":"Antonia J. M."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Basingstoke","dateIssuedDisp":"[1987?]-","publisher":"Nature Publishing Group"}],"id":{"issn":["1476-5454"],"zdb":["2080338-2"],"eki":["349234922"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 12.08.2021"],"disp":"Corneoscleroplasty with maintenance of the angle in two cases of extensive corneoscleral diseaseEye","recId":"349234922","language":["eng"],"pubHistory":["Volume 1, issue 1 (January 1987)-"],"part":{"year":"2000","issue":"2","pages":"196-200","volume":"14","text":"14(2000), 2, Seite 196-200","extent":"5"},"title":[{"subtitle":"official journal of the Royal College of Ophthalmologists","title":"Eye","title_sort":"Eye"}]}],"physDesc":[{"extent":"5 S."}],"id":{"doi":["10.1038/eye.2000.53"],"eki":["1808670353"]},"origin":[{"dateIssuedKey":"2000","dateIssuedDisp":"01 March 2000"}],"name":{"displayForm":["Reinhard O.W. Burk, Antonia M. Joussen"]}} 
SRT |a BURKREINHACORNEOSCLE0120