Image quality and radiation dose in 256-slice cardiac computed tomography: Comparison of prospective versus retrospective image acquisition protocols

Purpose - To assess coronary artery image quality and patient radiation exposure in patients who underwent clinically indicated 256-slice CTA. - Methods - Consecutive patients (n=193) underwent 256-slice CTA, using (1) retrospective gating without radiation dose modulation, (2) retrospective gating...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hosch, Waldemar P. (VerfasserIn) , Heye, Tobias (VerfasserIn) , Schulz, Felix (VerfasserIn) , Lehrke, Stephanie (VerfasserIn) , Schlieter, Martin (VerfasserIn) , Giannitsis, Evangelos (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Katus, Hugo (VerfasserIn) , Korosoglou, Grigorios (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2011
In: European journal of radiology
Year: 2011, Jahrgang: 80, Heft: 1, Pages: 127-135
ISSN:1872-7727
DOI:10.1016/j.ejrad.2010.07.011
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2010.07.011
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X10003463
Volltext
Verfasserangaben:Waldemar Hosch, Tobias Heye, Felix Schulz, Stephanie Lehrke, Martin Schlieter, Evangelos Giannitsis, Hans-Ulrich Kauczor, Hugo A. Katus, Grigorios Korosoglou

MARC

LEADER 00000caa a2200000 c 4500
001 1808684001
003 DE-627
005 20220820211504.0
007 cr uuu---uuuuu
008 220630s2011 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2010.07.011  |2 doi 
035 |a (DE-627)1808684001 
035 |a (DE-599)KXP1808684001 
035 |a (OCoLC)1341463316 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hosch, Waldemar P.  |d 1969-  |e VerfasserIn  |0 (DE-588)11585696X  |0 (DE-627)691639205  |0 (DE-576)290116562  |4 aut 
245 1 0 |a Image quality and radiation dose in 256-slice cardiac computed tomography  |b Comparison of prospective versus retrospective image acquisition protocols  |c Waldemar Hosch, Tobias Heye, Felix Schulz, Stephanie Lehrke, Martin Schlieter, Evangelos Giannitsis, Hans-Ulrich Kauczor, Hugo A. Katus, Grigorios Korosoglou 
264 1 |c 2011 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 13 August 2010 
500 |a Gesehen am 30.06.2022 
520 |a Purpose - To assess coronary artery image quality and patient radiation exposure in patients who underwent clinically indicated 256-slice CTA. - Methods - Consecutive patients (n=193) underwent 256-slice CTA, using (1) retrospective gating without radiation dose modulation, (2) retrospective gating with radiation dose modulation and (3) prospective gating. Image quality was determined by consensus of two experienced observers using a 5-grade scale. The effective dose was calculated. - Results - In all patients, CTA was performed without adverse events. Retrospective CTA was assessed in 39 patients with and 39 without dose modulation, while 115 patients underwent prospective CTA. Heart rate was related to image quality with all protocols (r=0.46, p<0.001). Up to a heart rate of 75bpm no significant difference in overall image quality was observed for all three protocols, while no significant differences could be observed between retrospective CTA with and without dose modulation for any segments or heart rates. Prospective and retrospective CTA with dose modulation showed radiation savings of ∼75% and ∼30%, respectively compared to retrospective CTA without dose modulation (p<0.001). - Conclusions - In patients with heart rates up to 75bpm prospective CTA should be the first choice acquisition protocol. For heart rates >75bpm, retrospective CTA with dose modulation should be considered. 
650 4 |a 256-Slice computed tomography angiography 
650 4 |a Dose modulation 
650 4 |a Image quality 
650 4 |a Prospective protocols 
650 4 |a Radiation exposure 
650 4 |a Retrospective protocols 
700 1 |a Heye, Tobias  |e VerfasserIn  |4 aut 
700 1 |a Schulz, Felix  |e VerfasserIn  |4 aut 
700 1 |a Lehrke, Stephanie  |d 1976-  |e VerfasserIn  |0 (DE-588)123769175  |0 (DE-627)706420756  |0 (DE-576)29387008X  |4 aut 
700 1 |a Schlieter, Martin  |e VerfasserIn  |4 aut 
700 1 |a Giannitsis, Evangelos  |e VerfasserIn  |0 (DE-588)113336241  |0 (DE-627)577184091  |0 (DE-576)289759579  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Katus, Hugo  |d 1951-  |e VerfasserIn  |0 (DE-588)108916618  |0 (DE-627)577155040  |0 (DE-576)289625076  |4 aut 
700 1 |a Korosoglou, Grigorios  |d 1976-  |e VerfasserIn  |0 (DE-588)12854225X  |0 (DE-627)374709025  |0 (DE-576)297204912  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 80(2011), 1, Seite 127-135  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Image quality and radiation dose in 256-slice cardiac computed tomography Comparison of prospective versus retrospective image acquisition protocols 
773 1 8 |g volume:80  |g year:2011  |g number:1  |g pages:127-135  |g extent:9  |a Image quality and radiation dose in 256-slice cardiac computed tomography Comparison of prospective versus retrospective image acquisition protocols 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2010.07.011  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X10003463  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220630 
993 |a Article 
994 |a 2011 
998 |g 12854225X  |a Korosoglou, Grigorios  |m 12854225X:Korosoglou, Grigorios  |d 50000  |e 50000PK12854225X  |k 0/50000/  |p 9  |y j 
998 |g 108916618  |a Katus, Hugo  |m 108916618:Katus, Hugo  |d 910000  |d 910100  |e 910000PK108916618  |e 910100PK108916618  |k 0/910000/  |k 1/910000/910100/  |p 8 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 113336241  |a Giannitsis, Evangelos  |m 113336241:Giannitsis, Evangelos  |d 910000  |d 910100  |d 50000  |e 910000PG113336241  |e 910100PG113336241  |e 50000PG113336241  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 6 
998 |g 123769175  |a Lehrke, Stephanie  |m 123769175:Lehrke, Stephanie  |d 50000  |e 50000PL123769175  |k 0/50000/  |p 4 
998 |g 11585696X  |a Hosch, Waldemar P.  |m 11585696X:Hosch, Waldemar P.  |d 50000  |e 50000PH11585696X  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1808684001  |e 4159301800 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1808684001"],"doi":["10.1016/j.ejrad.2010.07.011"]},"name":{"displayForm":["Waldemar Hosch, Tobias Heye, Felix Schulz, Stephanie Lehrke, Martin Schlieter, Evangelos Giannitsis, Hans-Ulrich Kauczor, Hugo A. Katus, Grigorios Korosoglou"]},"physDesc":[{"extent":"9 S."}],"recId":"1808684001","type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Available online 13 August 2010","Gesehen am 30.06.2022"],"title":[{"title":"Image quality and radiation dose in 256-slice cardiac computed tomography","title_sort":"Image quality and radiation dose in 256-slice cardiac computed tomography","subtitle":"Comparison of prospective versus retrospective image acquisition protocols"}],"origin":[{"dateIssuedDisp":"2011","dateIssuedKey":"2011"}],"person":[{"display":"Hosch, Waldemar P.","role":"aut","given":"Waldemar P.","family":"Hosch"},{"display":"Heye, Tobias","family":"Heye","role":"aut","given":"Tobias"},{"display":"Schulz, Felix","family":"Schulz","role":"aut","given":"Felix"},{"given":"Stephanie","role":"aut","family":"Lehrke","display":"Lehrke, Stephanie"},{"family":"Schlieter","role":"aut","given":"Martin","display":"Schlieter, Martin"},{"display":"Giannitsis, Evangelos","role":"aut","given":"Evangelos","family":"Giannitsis"},{"family":"Kauczor","given":"Hans-Ulrich","role":"aut","display":"Kauczor, Hans-Ulrich"},{"family":"Katus","role":"aut","given":"Hugo","display":"Katus, Hugo"},{"display":"Korosoglou, Grigorios","given":"Grigorios","role":"aut","family":"Korosoglou"}],"relHost":[{"disp":"Image quality and radiation dose in 256-slice cardiac computed tomography Comparison of prospective versus retrospective image acquisition protocolsEuropean journal of radiology","physDesc":[{"extent":"Online-Ressource"}],"recId":"32044483X","note":["Gesehen am 05.02.20"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"subtitle":"EJR","title":"European journal of radiology","title_sort":"European journal of radiology"}],"origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]"}],"part":{"text":"80(2011), 1, Seite 127-135","extent":"9","issue":"1","pages":"127-135","volume":"80","year":"2011"},"id":{"eki":["32044483X"],"issn":["1872-7727"],"zdb":["2005350-2"]},"pubHistory":["Nachgewiesen 10.1990 -"],"titleAlt":[{"title":"EJR"}]}]} 
SRT |a HOSCHWALDEIMAGEQUALI2011