Monitoring of the anticoagulants argatroban and lepirudin: a comparison of laboratory methods

Monitoring of direct inhibitors of thrombin (DTI) is critical for their safe and effective use as anticoagulants. We examined samples containing several concentrations of argatroban or lepirudin in reconstituted standard human plasma and plasma from medical outpatients and intensive care patients. P...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ivandic, Boris (VerfasserIn) , Zorn, Markus (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2011
In: Clinical and applied thrombosis, hemostasis
Year: 2011, Jahrgang: 17, Heft: 5, Pages: 549-555
ISSN:1938-2723
DOI:10.1177/1076029610382651
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1177/1076029610382651
Volltext
Verfasserangaben:Boris Ivandic, and Markus Zorn

MARC

LEADER 00000caa a2200000 c 4500
001 1808826949
003 DE-627
005 20220820212857.0
007 cr uuu---uuuuu
008 220704s2011 xx |||||o 00| ||eng c
024 7 |a 10.1177/1076029610382651  |2 doi 
035 |a (DE-627)1808826949 
035 |a (DE-599)KXP1808826949 
035 |a (OCoLC)1341463325 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ivandic, Boris  |e VerfasserIn  |0 (DE-588)1031172165  |0 (DE-627)735782245  |0 (DE-576)378581821  |4 aut 
245 1 0 |a Monitoring of the anticoagulants argatroban and lepirudin  |b a comparison of laboratory methods  |c Boris Ivandic, and Markus Zorn 
264 1 |c 2011 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published September 11, 2010 
500 |a Gesehen am 04.07.2022 
520 |a Monitoring of direct inhibitors of thrombin (DTI) is critical for their safe and effective use as anticoagulants. We examined samples containing several concentrations of argatroban or lepirudin in reconstituted standard human plasma and plasma from medical outpatients and intensive care patients. Prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin time (TT) were determined using automated analyzers. Ecarin clotting time (ECT) was measured using a 10 IU/mL dilution of ecarin in 0.05 mol/L CaCl2. Calibration curves were approximately linear for TT and ECT in samples containing argatroban and lepirudin, respectively. Activated partial thromboplastin curves reached a plateau at DTI concentrations ≥2 µg/mL, suggesting that the aPTT may not reliably detect overdosing. Prothrombin time increased exponentially. A broad range of clotting times was seen in patient samples with all tests suggesting that individual morbidity and therapies may strongly influence test results and may lead to underestimation of DTI doses. 
650 4 |a anticoagulants 
650 4 |a in vitro diagnostic systems 
650 4 |a thrombosis prophylaxis 
700 1 |a Zorn, Markus  |d 1964-  |e VerfasserIn  |0 (DE-588)1033873721  |0 (DE-627)745111483  |0 (DE-576)381543137  |4 aut 
773 0 8 |i Enthalten in  |t Clinical and applied thrombosis, hemostasis  |d Thousand Oaks, Calif. : Sage, 1995  |g 17(2011), 5, Seite 549-555  |h Online-Ressource  |w (DE-627)510464181  |w (DE-600)2230591-9  |w (DE-576)276272900  |x 1938-2723  |7 nnas  |a Monitoring of the anticoagulants argatroban and lepirudin a comparison of laboratory methods 
773 1 8 |g volume:17  |g year:2011  |g number:5  |g pages:549-555  |g extent:7  |a Monitoring of the anticoagulants argatroban and lepirudin a comparison of laboratory methods 
856 4 0 |u https://doi.org/10.1177/1076029610382651  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220704 
993 |a Article 
994 |a 2011 
998 |g 1033873721  |a Zorn, Markus  |m 1033873721:Zorn, Markus  |d 910000  |d 910100  |e 910000PZ1033873721  |e 910100PZ1033873721  |k 0/910000/  |k 1/910000/910100/  |p 2  |y j 
998 |g 1031172165  |a Ivandic, Boris  |m 1031172165:Ivandic, Boris  |d 50000  |e 50000PI1031172165  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1808826949  |e 4160714153 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"pubHistory":["1.1995 -"],"part":{"text":"17(2011), 5, Seite 549-555","volume":"17","extent":"7","year":"2011","pages":"549-555","issue":"5"},"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 25.05.2020","Fortsetzung der Druck-Ausgabe"],"disp":"Monitoring of the anticoagulants argatroban and lepirudin a comparison of laboratory methodsClinical and applied thrombosis, hemostasis","language":["eng"],"recId":"510464181","title":[{"title":"Clinical and applied thrombosis, hemostasis","title_sort":"Clinical and applied thrombosis, hemostasis"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisherPlace":"Thousand Oaks, Calif.","publisher":"Sage","dateIssuedKey":"1995","dateIssuedDisp":"1995-"}],"id":{"eki":["510464181"],"zdb":["2230591-9"],"issn":["1938-2723"]}}],"physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Boris Ivandic, and Markus Zorn"]},"id":{"doi":["10.1177/1076029610382651"],"eki":["1808826949"]},"origin":[{"dateIssuedDisp":"2011","dateIssuedKey":"2011"}],"language":["eng"],"recId":"1808826949","type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["First published September 11, 2010","Gesehen am 04.07.2022"],"person":[{"given":"Boris","family":"Ivandic","role":"aut","display":"Ivandic, Boris","roleDisplay":"VerfasserIn"},{"given":"Markus","family":"Zorn","role":"aut","roleDisplay":"VerfasserIn","display":"Zorn, Markus"}],"title":[{"title":"Monitoring of the anticoagulants argatroban and lepirudin","subtitle":"a comparison of laboratory methods","title_sort":"Monitoring of the anticoagulants argatroban and lepirudin"}]} 
SRT |a IVANDICBORMONITORING2011