Validating a new oscillometric device for aortic pulse wave velocity measurements in children and adolescents

Pulse wave velocity (PWV) is an indicator of aortic stiffness and a predictor of cardiovascular risk. Applanation tonometry (e.g., SphygmoCor) is a well-established method to measure aortic PWV (aPWV). The Vicorder, a new oscillometric device, has not been validated in children and adolescents.We pe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Thurn-Valsassina, Daniela (VerfasserIn) , Shroff, Rukshana (VerfasserIn) , Baig, Sabrina (VerfasserIn) , Doyon, Anke (VerfasserIn) , Jacobi, Christoph (VerfasserIn) , Zeller, Rene (VerfasserIn) , Querfeld, Uwe (VerfasserIn) , Schaefer, Franz (VerfasserIn) , Wühl, Elke (VerfasserIn) , Schmidt, Bernhard M.W. (VerfasserIn) , Melk, Anette (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 01 December 2011
In: American journal of hypertension
Year: 2011, Jahrgang: 24, Heft: 12, Pages: 1294-1299
ISSN:1941-7225
DOI:10.1038/ajh.2011.147
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1038/ajh.2011.147
Volltext
Verfasserangaben:Daniela Kracht, Rukshana Shroff, Sabrina Baig, Anke Doyon, Christoph Jacobi, Rene Zeller, Uwe Querfeld, Franz Schaefer, Elke Wühl, Bernhard M.W. Schmidt, and Anette Melk, for the 4C Study Consortium

MARC

LEADER 00000caa a2200000 c 4500
001 1809481465
003 DE-627
005 20220820220317.0
007 cr uuu---uuuuu
008 220708s2011 xx |||||o 00| ||eng c
024 7 |a 10.1038/ajh.2011.147  |2 doi 
035 |a (DE-627)1809481465 
035 |a (DE-599)KXP1809481465 
035 |a (OCoLC)1341463750 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Thurn-Valsassina, Daniela  |d 1979-  |e VerfasserIn  |0 (DE-588)140134999  |0 (DE-627)1680723634  |0 (DE-576)314729208  |4 aut 
245 1 0 |a Validating a new oscillometric device for aortic pulse wave velocity measurements in children and adolescents  |c Daniela Kracht, Rukshana Shroff, Sabrina Baig, Anke Doyon, Christoph Jacobi, Rene Zeller, Uwe Querfeld, Franz Schaefer, Elke Wühl, Bernhard M.W. Schmidt, and Anette Melk, for the 4C Study Consortium 
264 1 |c 01 December 2011 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.07.2022 
520 |a Pulse wave velocity (PWV) is an indicator of aortic stiffness and a predictor of cardiovascular risk. Applanation tonometry (e.g., SphygmoCor) is a well-established method to measure aortic PWV (aPWV). The Vicorder, a new oscillometric device, has not been validated in children and adolescents.We performed intra- and interobserver repeatability studies in 14 individuals using the Vicorder. Vicorder and SphygmoCor measurements were compared in 156 healthy children (6-18 years) using two different path length measurements.Intra- and interobserver repeatabilities of the Vicorder were excellent with coefficients of variation of 5.6% and 5.8% and intraclass correlation coefficients (ICCs) of 0.8 and 1.0. aPWV calculated using the distances (suprasternal notch-to-femoral recording point) - (suprasternal notch-to-carotid artery), the path length most commonly used in adults, revealed a mean of 4.8 ± 0.7 m/s for SphygmoCor and 4.9 ± 0.6 m/s for Vicorder. The percentage deviation between both devices was 13.0% and the limit of agreement (LoA) ranged from −1.0 to 1.7 m/s reflecting a good concordance. Using a path length that measured the distance from suprasternal notch to femoral recording point via the umbilicus (Umb), an even better agreement was found (percentage deviation: 11.8%, LoA: −1.0 to 1.6 m/s).Vicorder aPWV values are similar to those obtained by SphygmoCor applanation tonometry. The best agreement between devices was obtained with the path length that most accurately describes the aortic tree. Excellent intra- and interobserver repeatability and ease of measurements make Vicorder appropriate for large multicentre studies in children and adolescents.American Journal of Hypertension, advance online publication 25 August 2011; doi:10.1038/ajh.2011.147 
700 1 |a Shroff, Rukshana  |e VerfasserIn  |4 aut 
700 1 |a Baig, Sabrina  |e VerfasserIn  |4 aut 
700 1 |a Doyon, Anke  |d 1982-  |e VerfasserIn  |0 (DE-588)142072702  |0 (DE-627)633525391  |0 (DE-576)327507896  |4 aut 
700 1 |a Jacobi, Christoph  |e VerfasserIn  |4 aut 
700 1 |a Zeller, Rene  |e VerfasserIn  |4 aut 
700 1 |a Querfeld, Uwe  |e VerfasserIn  |4 aut 
700 1 |a Schaefer, Franz  |d 1961-  |e VerfasserIn  |0 (DE-588)1023365383  |0 (DE-627)718365577  |0 (DE-576)366705598  |4 aut 
700 1 |a Wühl, Elke  |e VerfasserIn  |0 (DE-588)1069939617  |0 (DE-627)823052052  |0 (DE-576)429626134  |4 aut 
700 1 |a Schmidt, Bernhard M.W.  |e VerfasserIn  |4 aut 
700 1 |a Melk, Anette  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t American journal of hypertension  |d Oxford : Oxford Univ. Press, 1988  |g 24(2011), 12, Seite 1294-1299  |h Online-Ressource  |w (DE-627)271180781  |w (DE-600)1479505-X  |w (DE-576)255691718  |x 1941-7225  |7 nnas  |a Validating a new oscillometric device for aortic pulse wave velocity measurements in children and adolescents 
773 1 8 |g volume:24  |g year:2011  |g number:12  |g pages:1294-1299  |g extent:6  |a Validating a new oscillometric device for aortic pulse wave velocity measurements in children and adolescents 
856 4 0 |u https://doi.org/10.1038/ajh.2011.147  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220708 
993 |a Article 
994 |a 2011 
998 |g 1069939617  |a Wühl, Elke  |m 1069939617:Wühl, Elke  |d 910000  |d 910500  |e 910000PW1069939617  |e 910500PW1069939617  |k 0/910000/  |k 1/910000/910500/  |p 9 
998 |g 1023365383  |a Schaefer, Franz  |m 1023365383:Schaefer, Franz  |d 910000  |d 910500  |d 50000  |e 910000PS1023365383  |e 910500PS1023365383  |e 50000PS1023365383  |k 0/910000/  |k 1/910000/910500/  |k 0/50000/  |p 8 
998 |g 142072702  |a Doyon, Anke  |m 142072702:Doyon, Anke  |d 910000  |d 910500  |e 910000PD142072702  |e 910500PD142072702  |k 0/910000/  |k 1/910000/910500/  |p 4 
999 |a KXP-PPN1809481465  |e 416268040X 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"title":[{"subtitle":"the official journal of the American Society of Hypertension","title_sort":"American journal of hypertension","title":"American journal of hypertension"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"text":"24(2011), 12, Seite 1294-1299","volume":"24","pages":"1294-1299","year":"2011","issue":"12","extent":"6"},"language":["eng"],"pubHistory":["1.1988 -"],"note":["Gesehen am 27.02.13","Ungezählte Beil.: Supplement"],"titleAlt":[{"title":"AJH"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"id":{"zdb":["1479505-X"],"eki":["271180781"],"issn":["1941-7225"]},"recId":"271180781","origin":[{"dateIssuedKey":"1988","publisherPlace":"Oxford ; Amsterdam [u.a.] ; Basingstoke","dateIssuedDisp":"1988-","publisher":"Oxford Univ. Press ; Elsevier ; Nature Publ. Group"}],"disp":"Validating a new oscillometric device for aortic pulse wave velocity measurements in children and adolescentsAmerican journal of hypertension"}],"title":[{"title_sort":"Validating a new oscillometric device for aortic pulse wave velocity measurements in children and adolescents","title":"Validating a new oscillometric device for aortic pulse wave velocity measurements in children and adolescents"}],"physDesc":[{"extent":"6 S."}],"language":["eng"],"note":["Gesehen am 08.07.2022"],"person":[{"given":"Daniela","role":"aut","family":"Thurn-Valsassina","display":"Thurn-Valsassina, Daniela"},{"family":"Shroff","role":"aut","display":"Shroff, Rukshana","given":"Rukshana"},{"display":"Baig, Sabrina","family":"Baig","role":"aut","given":"Sabrina"},{"display":"Doyon, Anke","family":"Doyon","role":"aut","given":"Anke"},{"given":"Christoph","display":"Jacobi, Christoph","role":"aut","family":"Jacobi"},{"given":"Rene","display":"Zeller, Rene","family":"Zeller","role":"aut"},{"role":"aut","family":"Querfeld","display":"Querfeld, Uwe","given":"Uwe"},{"given":"Franz","family":"Schaefer","role":"aut","display":"Schaefer, Franz"},{"given":"Elke","display":"Wühl, Elke","role":"aut","family":"Wühl"},{"given":"Bernhard M.W.","family":"Schmidt","role":"aut","display":"Schmidt, Bernhard M.W."},{"given":"Anette","display":"Melk, Anette","role":"aut","family":"Melk"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1809481465","id":{"eki":["1809481465"],"doi":["10.1038/ajh.2011.147"]},"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"01 December 2011"}],"name":{"displayForm":["Daniela Kracht, Rukshana Shroff, Sabrina Baig, Anke Doyon, Christoph Jacobi, Rene Zeller, Uwe Querfeld, Franz Schaefer, Elke Wühl, Bernhard M.W. Schmidt, and Anette Melk, for the 4C Study Consortium"]}} 
SRT |a THURNVALSAVALIDATING0120