A measurement setup for direct 17O MRI at 7 T

An efficient breathing system was designed for direct 17O MRI to perform oxygen metabolism studies of the human brain. The breathing system consists of a demand oxygen delivery device for 17O2 supply and a custom-built re-breathing circuit with pneumatic switching valve. To efficiently deliver the 1...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hoffmann, Stefan Heinrich (VerfasserIn) , Begovatz, Paul (VerfasserIn) , Nagel, Armin Michael (VerfasserIn) , Umathum, Reiner (VerfasserIn) , Schommer, Kai (VerfasserIn) , Bachert, Peter (VerfasserIn) , Bock, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [October 2011]
In: Magnetic resonance in medicine
Year: 2011, Jahrgang: 66, Heft: 4, Pages: 1109-1115
ISSN:1522-2594
DOI:10.1002/mrm.22871
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/mrm.22871
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.22871
Volltext
Verfasserangaben:Stefan H. Hoffmann, Paul Begovatz, Armin M. Nagel, Reiner Umathum, Kai Schommer, Peter Bachert, and Michael Bock

MARC

LEADER 00000caa a2200000 c 4500
001 1809689139
003 DE-627
005 20220820221121.0
007 cr uuu---uuuuu
008 220711s2011 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.22871  |2 doi 
035 |a (DE-627)1809689139 
035 |a (DE-599)KXP1809689139 
035 |a (OCoLC)1341463767 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hoffmann, Stefan Heinrich  |e VerfasserIn  |0 (DE-588)1043178163  |0 (DE-627)770192173  |0 (DE-576)394519485  |4 aut 
245 1 2 |a A measurement setup for direct 17O MRI at 7 T  |c Stefan H. Hoffmann, Paul Begovatz, Armin M. Nagel, Reiner Umathum, Kai Schommer, Peter Bachert, and Michael Bock 
246 3 3 |a A measurement setup for direct 17 O MRI at 7 T 
264 1 |c [October 2011] 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 09 March 2011 
500 |a Die 17 im Titel ist hochgestellt 
500 |a Gesehen am 11.07.2022 
520 |a An efficient breathing system was designed for direct 17O MRI to perform oxygen metabolism studies of the human brain. The breathing system consists of a demand oxygen delivery device for 17O2 supply and a custom-built re-breathing circuit with pneumatic switching valve. To efficiently deliver the 17O gas to the alveoli of the lungs, the system applies short gas pulses upon an inspiration trigger via a nasal cannula. During and after 17O2 administration, the exhaled gas volumes are stored and filtered in the re-breathing section to make the most efficient use of the rare 17O gas. In an inhalation experiment, 2.2 ± 0.1 L of 70%-enriched 17O2 were administered to a healthy volunteer and direct 17O MRI was performed for a total imaging time of 38 min with a temporal resolution of 50 s per 3D data set. Mapping of the maximum signal increase was carried out showing regional variations of oxygen concentration of up to 30% over the natural abundance of 17O water. Magn Reson Med, 2011. © 2011 Wiley-Liss, Inc. 
650 4 |a brain metabolism 
650 4 |a cerebral metabolic rate of oxygen consumption (CMRO2) 
650 4 |a direct 17O MRI 
650 4 |a high field MRI 
650 4 |a non-proton MRI 
650 4 |a oxygen-17 
700 1 |a Begovatz, Paul  |d 1982-  |e VerfasserIn  |0 (DE-588)1135732973  |0 (DE-627)890769923  |0 (DE-576)490077218  |4 aut 
700 1 |a Nagel, Armin Michael  |e VerfasserIn  |0 (DE-588)13791878X  |0 (DE-627)598153276  |0 (DE-576)305872141  |4 aut 
700 1 |a Umathum, Reiner  |e VerfasserIn  |0 (DE-588)1067822143  |0 (DE-627)81922698X  |0 (DE-576)426949471  |4 aut 
700 1 |a Schommer, Kai  |e VerfasserIn  |0 (DE-588)1037459881  |0 (DE-627)75577826X  |0 (DE-576)391490508  |4 aut 
700 1 |a Bachert, Peter  |e VerfasserIn  |0 (DE-588)1103529633  |0 (DE-627)861285824  |0 (DE-576)251203298  |4 aut 
700 1 |a Bock, Michael  |e VerfasserIn  |0 (DE-588)1140749323  |0 (DE-627)898660335  |0 (DE-576)494021470  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 66(2011), 4 vom: Okt., Seite 1109-1115  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a A measurement setup for direct 17O MRI at 7 T 
773 1 8 |g volume:66  |g year:2011  |g number:4  |g month:10  |g pages:1109-1115  |g extent:7  |a A measurement setup for direct 17O MRI at 7 T 
856 4 0 |u https://doi.org/10.1002/mrm.22871  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.22871  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220711 
993 |a Article 
994 |a 2011 
998 |g 1140749323  |a Bock, Michael  |m 1140749323:Bock, Michael  |d 130000  |e 130000PB1140749323  |k 0/130000/  |p 7  |y j 
998 |g 1103529633  |a Bachert, Peter  |m 1103529633:Bachert, Peter  |d 130000  |e 130000PB1103529633  |k 0/130000/  |p 6 
998 |g 1037459881  |a Schommer, Kai  |m 1037459881:Schommer, Kai  |d 910000  |d 910100  |e 910000PS1037459881  |e 910100PS1037459881  |k 0/910000/  |k 1/910000/910100/  |p 5 
998 |g 13791878X  |a Nagel, Armin Michael  |m 13791878X:Nagel, Armin Michael  |d 130000  |e 130000PN13791878X  |k 0/130000/  |p 3 
998 |g 1043178163  |a Hoffmann, Stefan Heinrich  |m 1043178163:Hoffmann, Stefan Heinrich  |d 130000  |d 130001  |e 130000PH1043178163  |e 130001PH1043178163  |k 0/130000/  |k 1/130000/130001/  |p 1  |x j 
999 |a KXP-PPN1809689139  |e 4163822380 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"origin":[{"publisherPlace":"New York, NY [u.a.]","dateIssuedDisp":"1984-","dateIssuedKey":"1984","publisher":"Wiley-Liss"}],"id":{"zdb":["1493786-4"],"eki":["303257040"],"doi":["10.1002/(ISSN)1522-2594"],"issn":["1522-2594"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Magnetic resonance in medicine","subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Magnetic resonance in medicine"}],"pubHistory":["1.1984 -"],"titleAlt":[{"title":"MRM"}],"part":{"text":"66(2011), 4 vom: Okt., Seite 1109-1115","volume":"66","extent":"7","year":"2011","pages":"1109-1115","issue":"4"},"disp":"A measurement setup for direct 17O MRI at 7 TMagnetic resonance in medicine","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28.02.08"],"language":["eng"],"recId":"303257040"}],"physDesc":[{"noteIll":"Illustrationen","extent":"7 S."}],"id":{"doi":["10.1002/mrm.22871"],"eki":["1809689139"]},"origin":[{"dateIssuedDisp":"[October 2011]","dateIssuedKey":"2011"}],"name":{"displayForm":["Stefan H. Hoffmann, Paul Begovatz, Armin M. Nagel, Reiner Umathum, Kai Schommer, Peter Bachert, and Michael Bock"]},"titleAlt":[{"title":"A measurement setup for direct 17 O MRI at 7 T"}],"language":["eng"],"recId":"1809689139","note":["First published: 09 March 2011","Die 17 im Titel ist hochgestellt","Gesehen am 11.07.2022"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"measurement setup for direct 17O MRI at 7 T","title":"A measurement setup for direct 17O MRI at 7 T"}],"person":[{"given":"Stefan Heinrich","family":"Hoffmann","role":"aut","display":"Hoffmann, Stefan Heinrich","roleDisplay":"VerfasserIn"},{"family":"Begovatz","given":"Paul","display":"Begovatz, Paul","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Nagel, Armin Michael","roleDisplay":"VerfasserIn","role":"aut","family":"Nagel","given":"Armin Michael"},{"given":"Reiner","family":"Umathum","role":"aut","display":"Umathum, Reiner","roleDisplay":"VerfasserIn"},{"given":"Kai","family":"Schommer","role":"aut","roleDisplay":"VerfasserIn","display":"Schommer, Kai"},{"role":"aut","display":"Bachert, Peter","roleDisplay":"VerfasserIn","given":"Peter","family":"Bachert"},{"family":"Bock","given":"Michael","roleDisplay":"VerfasserIn","display":"Bock, Michael","role":"aut"}]} 
SRT |a HOFFMANNSTMEASUREMEN2011