Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxaban

Rivaroxaban and other direct factor Xa inhibitors are used at fixed doses without drug monitoring and dose adjustment. Patients may require determination of the anticoagulant effect during treatment. The aim of this study was to develop a method to reduce the differences between thromboplastin reage...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Harenberg, Job (VerfasserIn) , Hetjens, Svetlana (VerfasserIn) , Krämer, Roland (VerfasserIn) , Giese, Christina (VerfasserIn) , Weiß, Christel (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2011
In: Blood coagulation & fibrinolysis
Year: 2011, Jahrgang: 22, Heft: 8, Pages: 637-641
ISSN:1473-5733
DOI:10.1097/MBC.0b013e328349f1d6
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/MBC.0b013e328349f1d6
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/bloodcoagulation/Fulltext/2011/12000/Determination_of_an_international_sensitivity.2.aspx
Volltext
Verfasserangaben:Job Harenberg, Svetlana Marx, Roland Krämer, Christina Giese and Christel Weiss

MARC

LEADER 00000caa a2200000 c 4500
001 1813079218
003 DE-627
005 20230427070238.0
007 cr uuu---uuuuu
008 220803s2011 xx |||||o 00| ||eng c
024 7 |a 10.1097/MBC.0b013e328349f1d6  |2 doi 
035 |a (DE-627)1813079218 
035 |a (DE-599)KXP1813079218 
035 |a (OCoLC)1341464572 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Harenberg, Job  |d 1950-  |e VerfasserIn  |0 (DE-588)108825507  |0 (DE-627)655891498  |0 (DE-576)339563745  |4 aut 
245 1 0 |a Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxaban  |c Job Harenberg, Svetlana Marx, Roland Krämer, Christina Giese and Christel Weiss 
264 1 |c 2011 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.08.2022 
520 |a Rivaroxaban and other direct factor Xa inhibitors are used at fixed doses without drug monitoring and dose adjustment. Patients may require determination of the anticoagulant effect during treatment. The aim of this study was to develop a method to reduce the differences between thromboplastin reagents and coagulation analysers for determination of the anticoagulant effect of rivaroxaban in human plasma. Purity of rivaroxaban extracted from commercially available drug was confirmed by mass spectrometry, elemental analysis and 1H-NMR spectroscopy. Coagulation times of pooled human plasma spiked with 50-900 ng/ml rivaroxaban were analysed. Thromboplastin reagents, WHO RBT/90, Innovin, RecombiPlasTin 2G, STA Neoplastin Plus, Technoclot PT Plus and Thromborel S, the manual Kolle-Hook method and the KC10 analyser were used. An international sensitivity index (ISI) was determined for each reagent and coagulation method using the RBT/90 thromboplastin reagent as reference. The orthogonal, used for the determination of the ISI of coumarin plasmas, and ordinary regression analyses were compared. The results showed than increasing concentrations of rivaroxaban prolonged coagulation values of all thromboplastin assays linearly (r2 = 0.96 and r2 = 0.99, respectively). The coefficient of variation between the slopes of the dilution curves and the ratios of the thromboplastin reagents were reduced using the international normalized ratio (INR) and ISI calculated for rivaroxaban. The ISIs of the thromboplastin reagents ranged from 0.73 to 1.67 as compared with the WHO reagent using the manual technique. The coefficient of variations between the thromboplastin reagents comparing the orthogonal and the ordinary regression analysis were 6.8 versus 3.7% (Kolle-Hook method, P = 0.0011) and 8.5 versus 4.8% (KC10 method, P < 0.0001). Using ISI for vitamin-K antagonist and rivaroxaban, the INRs for the rivaroxaban-containing samples were significantly different for one of five commercial thromboplastin reagents. In conclusion, the determination of an ISI for rivaroxaban using a WHO thromboplastin reagent is required for commercial thromboplastin reagents. The manual Kolle-Hook method and an ordinary linear regression analysis should be adopted. 
700 1 |a Hetjens, Svetlana  |d 1983-  |e VerfasserIn  |0 (DE-588)1031801979  |0 (DE-627)737600284  |0 (DE-576)379534223  |4 aut 
700 1 |a Krämer, Roland  |e VerfasserIn  |0 (DE-588)1020469730  |0 (DE-627)691227861  |0 (DE-576)360500331  |4 aut 
700 1 |a Giese, Christina  |e VerfasserIn  |0 (DE-588)1033633763  |0 (DE-627)742103390  |0 (DE-576)381258262  |4 aut 
700 1 |a Weiß, Christel  |d 1958-  |e VerfasserIn  |0 (DE-588)123287707  |0 (DE-627)082463417  |0 (DE-576)168356104  |4 aut 
773 0 8 |i Enthalten in  |t Blood coagulation & fibrinolysis  |d Hagerstown, Md. : Lippincott, Williams & Wilkins, 1990  |g 22(2011), 8, Seite 637-641  |h Online-Ressource  |w (DE-627)325296014  |w (DE-600)2035229-3  |w (DE-576)103189505  |x 1473-5733  |7 nnas  |a Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxaban 
773 1 8 |g volume:22  |g year:2011  |g number:8  |g pages:637-641  |g extent:5  |a Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxaban 
856 4 0 |u https://doi.org/10.1097/MBC.0b013e328349f1d6  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/bloodcoagulation/Fulltext/2011/12000/Determination_of_an_international_sensitivity.2.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220803 
993 |a Article 
994 |a 2011 
998 |g 123287707  |a Weiß, Christel  |m 123287707:Weiß, Christel  |d 60000  |d 60200  |d 60250  |d 60000  |e 60000PW123287707  |e 60200PW123287707  |e 60250PW123287707  |e 60000PW123287707  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60250/  |k 0/60000/  |p 5  |y j 
998 |g 1033633763  |a Giese, Christina  |m 1033633763:Giese, Christina  |d 60000  |d 65400  |e 60000PG1033633763  |e 65400PG1033633763  |k 0/60000/  |k 1/60000/65400/  |p 4 
998 |g 1020469730  |a Krämer, Roland  |m 1020469730:Krämer, Roland  |d 120000  |d 120200  |e 120000PK1020469730  |e 120200PK1020469730  |k 0/120000/  |k 1/120000/120200/  |p 3 
998 |g 1031801979  |a Hetjens, Svetlana  |m 1031801979:Hetjens, Svetlana  |d 60000  |d 65400  |e 60000PH1031801979  |e 65400PH1031801979  |k 0/60000/  |k 1/60000/65400/  |p 2 
998 |g 108825507  |a Harenberg, Job  |m 108825507:Harenberg, Job  |d 60000  |d 65400  |d 60000  |e 60000PH108825507  |e 65400PH108825507  |e 60000PH108825507  |k 0/60000/  |k 1/60000/65400/  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1813079218  |e 4175544704 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1097/MBC.0b013e328349f1d6"],"eki":["1813079218"]},"physDesc":[{"extent":"5 S."}],"note":["Gesehen am 03.08.2022"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"id":{"issn":["1473-5733"],"zdb":["2035229-3"],"eki":["325296014"]},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 17.10.05"],"part":{"issue":"8","pages":"637-641","year":"2011","volume":"22","extent":"5","text":"22(2011), 8, Seite 637-641"},"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.1990 -"],"recId":"325296014","origin":[{"dateIssuedKey":"1990","publisherPlace":"Hagerstown, Md. ; [Erscheinungsort nicht ermittelbar]","dateIssuedDisp":"1990-","publisher":"Lippincott, Williams & Wilkins ; Ovid"}],"disp":"Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxabanBlood coagulation & fibrinolysis","language":["eng"],"title":[{"title":"Blood coagulation & fibrinolysis","title_sort":"Blood coagulation & fibrinolysis"}]}],"recId":"1813079218","origin":[{"dateIssuedDisp":"2011","dateIssuedKey":"2011"}],"person":[{"roleDisplay":"VerfasserIn","role":"aut","given":"Job","display":"Harenberg, Job","family":"Harenberg"},{"roleDisplay":"VerfasserIn","given":"Svetlana","role":"aut","display":"Hetjens, Svetlana","family":"Hetjens"},{"display":"Krämer, Roland","family":"Krämer","given":"Roland","role":"aut","roleDisplay":"VerfasserIn"},{"given":"Christina","role":"aut","family":"Giese","display":"Giese, Christina","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","display":"Weiß, Christel","family":"Weiß","role":"aut","given":"Christel"}],"language":["eng"],"title":[{"title":"Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxaban","title_sort":"Determination of an international sensitivity index of thromboplastin reagents using a WHO thromboplastin as calibrator for plasma spiked with rivaroxaban"}],"name":{"displayForm":["Job Harenberg, Svetlana Marx, Roland Krämer, Christina Giese and Christel Weiss"]}} 
SRT |a HARENBERGJDETERMINAT2011