Reply to Comment on The effect of a spectral filter on visual quality in patients with an extended-depth-of-focus intraocular lens

We present the case of a 36-year old Curschmann-Steinert myotonic dystrophy patient with posterior subcapsular cataract that we treated with unilateral implantation of an extended depth of focus intraocular lens to address his wish for spectacle independence at far and intermediate distance. - The p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Łabuz, Grzegorz (VerfasserIn) , Auffarth, Gerd U. (VerfasserIn) , Özen, Aydin (VerfasserIn) , van den Berg, Thomas J. T. P. (VerfasserIn) , Yildirim, Timur Mert (VerfasserIn) , Son, Hyeck Soo (VerfasserIn) , Khoramnia, Ramin (VerfasserIn)
Dokumenttyp: Article (Journal) Editorial
Sprache:Englisch
Veröffentlicht: May 2020
In: American journal of ophthalmology
Year: 2020, Jahrgang: 213, Pages: 322
ISSN:1879-1891
DOI:10.1016/j.ajo.2020.01.021
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ajo.2020.01.021
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0002939420300301
Volltext
Verfasserangaben:Grzegorz Łabuz, Gerd U. Auffarth, Aydin Özen, Heidelberg, Germany, Thomas J.T.P. van den Berg, Amsterdam, The Netherlands, Timur M. Yildirim, Hyeck-Soo Son, Ramin Khoramnia, Heidelberg, Germany
Beschreibung
Zusammenfassung:We present the case of a 36-year old Curschmann-Steinert myotonic dystrophy patient with posterior subcapsular cataract that we treated with unilateral implantation of an extended depth of focus intraocular lens to address his wish for spectacle independence at far and intermediate distance. - The patient underwent phacoemulsification with subsequent implantation of the AcrySof IQ Vivity IOL (Alcon, Fort Worth, TX, USA) in his left eye. Uncorrected distance visual acuity (UDVA) on the left eye increased from +0.40 logMAR preoperatively to −0.12 logMAR at 3 months postoperatively. At the three months follow-up distance corrected intermediate visual acuity (DCIVA) at 80 cm distance was −0.08 logMAR and DCIVA at 66 cm distance was 0.14 logMAR for the left eye. The defocus curve showed a functional defocus of 2.0 diopters at 0.2 logMAR or better, corresponding to the extended depth of focus. Dysphotopsia evaluation with a Halo & Glare simulator (Eyeland-Design Network GmbH, Vreden, Germany) revealed a very low level of photic phenomena. - Unilateral implantation of a new generation, non-diffractive extended depth of focus IOL was well tolerated and provided good functional results for far and intermediate distances. The patient reported a very low level of photic phenomena.