Sensor-based nerve compression measurement: a scoping review of current concepts and a preclinical evaluation of commercial microsensors

Background: Chronic nerve compression is the most common indication for nerve surgery. However, the clinical diagnosis still relies on surrogate parameters since devices for direct nerve compression pressure measurement (DNCPM) are clinically unavailable yet.Objectives: To review previous approaches...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Däschler, Simeon C. (VerfasserIn) , Wienbruch, Rebecca (VerfasserIn) , Bursacovschi, Catalina (VerfasserIn) , Zimmermann, Kim S. (VerfasserIn) , Nemariam, Selam Bekure (VerfasserIn) , Harhaus-Wähner, Leila (VerfasserIn) , Kneser, Ulrich (VerfasserIn) , Dehé, Alfons (VerfasserIn) , Bittner, Achim (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 11 July 2022
In: Frontiers in Bioengineering and Biotechnology
Year: 2022, Jahrgang: 10, Pages: 1-10
ISSN:2296-4185
Online-Zugang:Verlag, kostenfrei, Volltext: https://www.frontiersin.org/articles/10.3389/fbioe.2022.868396
Volltext
Verfasserangaben:Simeon C. Daeschler, Rebecca Wienbruch, Catalina Bursacovschi, Kim Sophie Zimmermann, Selam Bekure Nemariam, Leila Harhaus, Ulrich Kneser, Alfons Dehé and Achim Bittner

MARC

LEADER 00000caa a2200000 c 4500
001 1814729216
003 DE-627
005 20251222145944.0
007 cr uuu---uuuuu
008 220819s2022 xx |||||o 00| ||eng c
024 7 |a 10.3389/fbioe.2022.868396  |2 doi 
035 |a (DE-627)1814729216 
035 |a (DE-599)KXP1814729216 
035 |a (OCoLC)1360439155 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Däschler, Simeon C.  |d 1991-  |e VerfasserIn  |0 (DE-588)1166617173  |0 (DE-627)1030514984  |0 (DE-576)510826733  |4 aut 
245 1 0 |a Sensor-based nerve compression measurement  |b a scoping review of current concepts and a preclinical evaluation of commercial microsensors  |c Simeon C. Daeschler, Rebecca Wienbruch, Catalina Bursacovschi, Kim Sophie Zimmermann, Selam Bekure Nemariam, Leila Harhaus, Ulrich Kneser, Alfons Dehé and Achim Bittner 
264 1 |c 11 July 2022 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.08.2022 
520 |a Background: Chronic nerve compression is the most common indication for nerve surgery. However, the clinical diagnosis still relies on surrogate parameters since devices for direct nerve compression pressure measurement (DNCPM) are clinically unavailable yet.Objectives: To review previous approaches to DNCPM and evaluate presently available microsensor systems for their feasibility and reliability in preclinical nerve compression models.Methods: A scoping literature review was conducted in accordance with the PRISMA-ScR guidelines. A subsequent market research aimed at identifying commercially available sensor systems potentially suitable for DNCPM. Sensors were evaluated for feasibility and safety of perineural sensor positioning, tissue compatibility and measurement reliability in a synthetic nerve compression model and an ex-vivo chicken leg model.Results: A scoping literature review identified 197 potentially eligible studies of which 65 were included in the analysis. Previous approaches to DNCPM predominantly used pressure sensing catheters designed for fluid- or intra-compartmental pressure measurement. A market research identified two piezoresistive sensor systems (IntraSense, SMi, United States; Mikro-Cath, Millar, United States) as potentially suitable for intraoperative DNCPM. In both preclinical models, the detected compression pressure differed significantly between sensors and systems showed substantial measurement variability with a median percent coefficient of variation between 15.5% and 32%. Sensor position was accountable for up to 99.1% of the variance.Conclusion: Measurement variability caused by unreliable sensor positioning is a key limitation of presently available sensors when applied for nerve compression measurements. Redesigned systems with small, flat-shaped and longitudinally oriented sensors and dedicated introducers would facilitate sensor positioning and therefore may allow for reliable measurements. 
700 1 |a Wienbruch, Rebecca  |e VerfasserIn  |4 aut 
700 1 |a Bursacovschi, Catalina  |d 1994-  |e VerfasserIn  |0 (DE-588)1385019182  |0 (DE-627)1947515608  |4 aut 
700 1 |a Zimmermann, Kim S.  |d 1997-  |e VerfasserIn  |0 (DE-588)1319361765  |0 (DE-627)1880742365  |4 aut 
700 1 |a Nemariam, Selam Bekure  |e VerfasserIn  |4 aut 
700 1 |a Harhaus-Wähner, Leila  |d 1980-  |e VerfasserIn  |0 (DE-588)132529874  |0 (DE-627)523625944  |0 (DE-576)299205185  |4 aut 
700 1 |a Kneser, Ulrich  |d 1972-  |e VerfasserIn  |0 (DE-588)123065119  |0 (DE-627)706147219  |0 (DE-576)293539987  |4 aut 
700 1 |a Dehé, Alfons  |d 1967-  |e VerfasserIn  |0 (DE-588)120273683  |0 (DE-627)69652192X  |0 (DE-576)292131690  |4 aut 
700 1 |a Bittner, Achim  |d 1980-  |e VerfasserIn  |0 (DE-588)140972358  |0 (DE-627)623803461  |0 (DE-576)320921948  |4 aut 
773 0 8 |i Enthalten in  |t Frontiers in Bioengineering and Biotechnology  |d Lausanne : Frontiers Media, 2013  |g 10(2022), Artikel-ID 868396, Seite 1-10  |h Online-Ressource  |w (DE-627)74950403X  |w (DE-600)2719493-0  |w (DE-576)383523621  |x 2296-4185  |7 nnas  |a Sensor-based nerve compression measurement a scoping review of current concepts and a preclinical evaluation of commercial microsensors 
773 1 8 |g volume:10  |g year:2022  |g elocationid:868396  |g pages:1-10  |g extent:10  |a Sensor-based nerve compression measurement a scoping review of current concepts and a preclinical evaluation of commercial microsensors 
856 4 0 |u https://www.frontiersin.org/articles/10.3389/fbioe.2022.868396  |x Verlag  |z kostenfrei  |3 Volltext  |7 0 
951 |a AR 
992 |a 20220819 
993 |a Article 
994 |a 2022 
998 |g 123065119  |a Kneser, Ulrich  |m 123065119:Kneser, Ulrich  |d 910000  |d 910400  |d 50000  |e 910000PK123065119  |e 910400PK123065119  |e 50000PK123065119  |k 0/910000/  |k 1/910000/910400/  |k 0/50000/  |p 7 
998 |g 132529874  |a Harhaus-Wähner, Leila  |m 132529874:Harhaus-Wähner, Leila  |d 50000  |e 50000PH132529874  |k 0/50000/  |p 6 
998 |g 1319361765  |a Zimmermann, Kim S.  |m 1319361765:Zimmermann, Kim S.  |d 50000  |e 50000PZ1319361765  |k 0/50000/  |p 4 
999 |a KXP-PPN1814729216  |e 4181012379 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"subtitle":"a scoping review of current concepts and a preclinical evaluation of commercial microsensors","title":"Sensor-based nerve compression measurement","title_sort":"Sensor-based nerve compression measurement"}],"recId":"1814729216","name":{"displayForm":["Simeon C. Daeschler, Rebecca Wienbruch, Catalina Bursacovschi, Kim Sophie Zimmermann, Selam Bekure Nemariam, Leila Harhaus, Ulrich Kneser, Alfons Dehé and Achim Bittner"]},"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"11 July 2022"}],"person":[{"display":"Däschler, Simeon C.","role":"aut","given":"Simeon C.","family":"Däschler"},{"given":"Rebecca","family":"Wienbruch","display":"Wienbruch, Rebecca","role":"aut"},{"given":"Catalina","family":"Bursacovschi","display":"Bursacovschi, Catalina","role":"aut"},{"given":"Kim S.","family":"Zimmermann","display":"Zimmermann, Kim S.","role":"aut"},{"family":"Nemariam","given":"Selam Bekure","role":"aut","display":"Nemariam, Selam Bekure"},{"role":"aut","display":"Harhaus-Wähner, Leila","family":"Harhaus-Wähner","given":"Leila"},{"given":"Ulrich","family":"Kneser","display":"Kneser, Ulrich","role":"aut"},{"given":"Alfons","family":"Dehé","display":"Dehé, Alfons","role":"aut"},{"role":"aut","display":"Bittner, Achim","family":"Bittner","given":"Achim"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 19.08.2022"],"relHost":[{"recId":"74950403X","language":["eng"],"titleAlt":[{"title":"FBIOE"}],"title":[{"title":"Frontiers in Bioengineering and Biotechnology","title_sort":"Frontiers in Bioengineering and Biotechnology"}],"part":{"text":"10(2022), Artikel-ID 868396, Seite 1-10","extent":"10","pages":"1-10","volume":"10","year":"2022"},"pubHistory":["2013 -"],"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["2296-4185"],"zdb":["2719493-0"],"eki":["74950403X"]},"disp":"Sensor-based nerve compression measurement a scoping review of current concepts and a preclinical evaluation of commercial microsensorsFrontiers in Bioengineering and Biotechnology","origin":[{"publisherPlace":"Lausanne","dateIssuedDisp":"2013-","publisher":"Frontiers Media","dateIssuedKey":"2013"}],"note":["Gesehen am 04.06.20"],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"id":{"doi":["10.3389/fbioe.2022.868396"],"eki":["1814729216"]},"physDesc":[{"extent":"10 S."}]} 
SRT |a DAESCHLERSSENSORBASE1120