Repeatability and reproducibility of quantitative whole-lung perfusion magnetic resonance imaging

Purpose - Magnetic resonance imaging (MRI) allows for quantitative evaluation of pulmonary perfusion and has shown high clinical usefulness for the evaluation and differentiation of different lung pathologies. The reproducibility of quantitative analysis of whole-lung perfusion has not been...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ley-Zaporozhan, Julia (VerfasserIn) , Molinari, Francesco (VerfasserIn) , Risse, Frank (VerfasserIn) , Puderbach, Michael (VerfasserIn) , Schenk, Jens-Peter (VerfasserIn) , Kopp-Schneider, Annette (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Ley, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2011
In: Journal of thoracic imaging
Year: 2011, Jahrgang: 26, Heft: 3, Pages: 230-239
ISSN:1536-0237
DOI:10.1097/RTI.0b013e3181e48c36
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/RTI.0b013e3181e48c36
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/thoracicimaging/Abstract/2011/08000/Repeatability_and_Reproducibility_of_Quantitative.10.aspx
Volltext
Verfasserangaben:Julia Ley-Zaporozhan, Francesco Molinari, Frank Risse, Michael Puderbach, Jens-Peter Schenk, Annette Kopp-Schneider, Hans-Ulrich Kauczor, Sebastian Ley

MARC

LEADER 00000caa a22000002c 4500
001 1814745572
003 DE-627
005 20240416194120.0
007 cr uuu---uuuuu
008 220819s2011 xx |||||o 00| ||eng c
024 7 |a 10.1097/RTI.0b013e3181e48c36  |2 doi 
035 |a (DE-627)1814745572 
035 |a (DE-599)KXP1814745572 
035 |a (OCoLC)1389793132 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ley-Zaporozhan, Julia  |d 1978-  |e VerfasserIn  |0 (DE-588)12910468X  |0 (DE-627)389534633  |0 (DE-576)297496026  |4 aut 
245 1 0 |a Repeatability and reproducibility of quantitative whole-lung perfusion magnetic resonance imaging  |c Julia Ley-Zaporozhan, Francesco Molinari, Frank Risse, Michael Puderbach, Jens-Peter Schenk, Annette Kopp-Schneider, Hans-Ulrich Kauczor, Sebastian Ley 
264 1 |c 2011 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.08.2022 
520 |a Purpose - Magnetic resonance imaging (MRI) allows for quantitative evaluation of pulmonary perfusion and has shown high clinical usefulness for the evaluation and differentiation of different lung pathologies. The reproducibility of quantitative analysis of whole-lung perfusion has not been investigated previously. Our aim was to assess the intraobserver and interobserver repeatability and reproducibility of perfusion MRI to prove the concept that perfusion is suitable for therapy monitoring. - Materials and Methods - The study was approved by the International Review Board. Fourteen healthy volunteers were examined using a time-resolved FLASH 3-dimensional perfusion sequence (1.5-T MRI, TREAT, GRAPPA 2, coronal orientation, voxel size 3.9×3.9×6.3 mm3). Perfusion was assessed initially and after 24 hours during an inspiratory and an expiratory breath hold. For each examination, 0.05 mmol/kg BW of Gd-DTPA was injected. Perfusion parameters such as pulmonary blood flow (PBF), pulmonary blood volume, and mean transit time were calculated. The evaluation was performed independently by 2 blinded observers. Intraobserver and interobserver differences were determined. - Results - The intraobserver differences between the initial and follow-up examinations for pulmonary blood volume, mean transit time, and time to peak were not significantly different for observers 1 and 2. PBF showed a significant difference for both observers only on inspiration (P<0.006 for observer 1 and P<0.009 for observer 2). For interobserver evaluation, all parameters, except inspiratory PBF, were significantly different (P<0.0001). - Conclusions - Intraobserver quantitative perfusion MRI showed reproducible results. However, the evaluation is highly dependent on the observer. Therefore, quantitative analysis of the serial examinations should be performed by the same observer. 
700 1 |a Molinari, Francesco  |e VerfasserIn  |4 aut 
700 1 |a Risse, Frank  |d 1974-  |e VerfasserIn  |0 (DE-588)129357359  |0 (DE-627)393983145  |0 (DE-576)297617621  |4 aut 
700 1 |a Puderbach, Michael  |d 1974-  |e VerfasserIn  |0 (DE-588)123953669  |0 (DE-627)085545880  |0 (DE-576)293957452  |4 aut 
700 1 |a Schenk, Jens-Peter  |e VerfasserIn  |0 (DE-588)1055855114  |0 (DE-627)792738667  |0 (DE-576)260795577  |4 aut 
700 1 |a Kopp-Schneider, Annette  |e VerfasserIn  |0 (DE-588)1119160545  |0 (DE-627)872460444  |0 (DE-576)178153206  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Ley, Sebastian  |d 1974-  |e VerfasserIn  |0 (DE-588)123561256  |0 (DE-627)706346858  |0 (DE-576)293766835  |4 aut 
773 0 8 |i Enthalten in  |t Journal of thoracic imaging  |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1985  |g 26(2011), 3, Seite 230-239  |h Online-Ressource  |w (DE-627)330078178  |w (DE-600)2048799-X  |w (DE-576)263808351  |x 1536-0237  |7 nnas  |a Repeatability and reproducibility of quantitative whole-lung perfusion magnetic resonance imaging 
773 1 8 |g volume:26  |g year:2011  |g number:3  |g pages:230-239  |g extent:10  |a Repeatability and reproducibility of quantitative whole-lung perfusion magnetic resonance imaging 
856 4 0 |u https://doi.org/10.1097/RTI.0b013e3181e48c36  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/thoracicimaging/Abstract/2011/08000/Repeatability_and_Reproducibility_of_Quantitative.10.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220819 
993 |a Article 
994 |a 2011 
998 |g 123561256  |a Ley, Sebastian  |m 123561256:Ley, Sebastian  |p 8  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1119160545  |a Kopp-Schneider, Annette  |m 1119160545:Kopp-Schneider, Annette  |d 50000  |e 50000PK1119160545  |k 0/50000/  |p 6 
998 |g 1055855114  |a Schenk, Jens-Peter  |m 1055855114:Schenk, Jens-Peter  |d 910000  |d 911400  |e 910000PS1055855114  |e 911400PS1055855114  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 123953669  |a Puderbach, Michael  |m 123953669:Puderbach, Michael  |d 910000  |d 950000  |d 950900  |d 50000  |e 910000PP123953669  |e 950000PP123953669  |e 950900PP123953669  |e 50000PP123953669  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |k 0/50000/  |p 4 
998 |g 129357359  |a Risse, Frank  |m 129357359:Risse, Frank  |d 50000  |e 50000PR129357359  |k 0/50000/  |p 3 
998 |g 12910468X  |a Ley-Zaporozhan, Julia  |m 12910468X:Ley-Zaporozhan, Julia  |d 910000  |d 911400  |e 910000PL12910468X  |e 911400PL12910468X  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1814745572  |e 4181043711 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Repeatability and reproducibility of quantitative whole-lung perfusion magnetic resonance imaging","title":"Repeatability and reproducibility of quantitative whole-lung perfusion magnetic resonance imaging"}],"note":["Gesehen am 19.08.2022"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"role":"aut","given":"Julia","family":"Ley-Zaporozhan","display":"Ley-Zaporozhan, Julia"},{"display":"Molinari, Francesco","given":"Francesco","role":"aut","family":"Molinari"},{"display":"Risse, Frank","family":"Risse","role":"aut","given":"Frank"},{"given":"Michael","role":"aut","family":"Puderbach","display":"Puderbach, Michael"},{"role":"aut","given":"Jens-Peter","family":"Schenk","display":"Schenk, Jens-Peter"},{"display":"Kopp-Schneider, Annette","family":"Kopp-Schneider","given":"Annette","role":"aut"},{"display":"Kauczor, Hans-Ulrich","role":"aut","given":"Hans-Ulrich","family":"Kauczor"},{"family":"Ley","given":"Sebastian","role":"aut","display":"Ley, Sebastian"}],"relHost":[{"origin":[{"publisher":"Lippincott Williams & Wilkins ; Ovid","dateIssuedKey":"1985","dateIssuedDisp":"1985-","publisherPlace":"Philadelphia, Pa. ; [Erscheinungsort nicht ermittelbar]"}],"pubHistory":["1.1985 -"],"id":{"zdb":["2048799-X"],"eki":["330078178"],"issn":["1536-0237"]},"part":{"volume":"26","year":"2011","text":"26(2011), 3, Seite 230-239","extent":"10","issue":"3","pages":"230-239"},"title":[{"title_sort":"Journal of thoracic imaging","title":"Journal of thoracic imaging","subtitle":"official journal of the Society of Thoracic Radiology, Japanese Society of Thoracic Radiology and the Korean Society of Thoracic Radiology"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 04.02.25","Fortsetzung der Druck-Ausgabe"],"recId":"330078178","physDesc":[{"extent":"Online-Ressource"}],"disp":"Repeatability and reproducibility of quantitative whole-lung perfusion magnetic resonance imagingJournal of thoracic imaging"}],"origin":[{"dateIssuedDisp":"2011","dateIssuedKey":"2011"}],"recId":"1814745572","physDesc":[{"extent":"10 S."}],"id":{"eki":["1814745572"],"doi":["10.1097/RTI.0b013e3181e48c36"]},"name":{"displayForm":["Julia Ley-Zaporozhan, Francesco Molinari, Frank Risse, Michael Puderbach, Jens-Peter Schenk, Annette Kopp-Schneider, Hans-Ulrich Kauczor, Sebastian Ley"]}} 
SRT |a LEYZAPOROZREPEATABIL2011