Comparison of optic disc ovality index and rotation angle measurements in myopic eyes using photography and OCT based techniques

Purpose: To compare optic nerve head (ONH) ovality index and rotation angle measurements based on semi-automated delineation of the clinical ONH margin derived from photographs and automated BMO configuration derived from optical coherence tomography (OCT) images in healthy and glaucomatous eyes wit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rezapour, Jasmin (VerfasserIn) , Tran, Andrew Q. (VerfasserIn) , Bowd, Christopher (VerfasserIn) , El-Nimri, Nevin W. (VerfasserIn) , Belghith, Akram (VerfasserIn) , Christopher, Mark (VerfasserIn) , Brye, Nicole (VerfasserIn) , Proudfoot, James A. (VerfasserIn) , Dohleman, Jade (VerfasserIn) , Fazio, Massimo A. (VerfasserIn) , Jonas, Jost B. (VerfasserIn) , Weinreb, Robert N. (VerfasserIn) , Zangwill, Linda M. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 24 June 2022
In: Frontiers in medicine
Year: 2022, Jahrgang: 9, Pages: 1-11
ISSN:2296-858X
DOI:10.3389/fmed.2022.872658
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3389/fmed.2022.872658
Volltext
Verfasserangaben:Jasmin Rezapour, Andrew Q. Tran, Christopher Bowd, Nevin W. El-Nimri, Akram Belghith, Mark Christopher, Nicole Brye, James A. Proudfoot, Jade Dohleman, Massimo A. Fazio, Jost B. Jonas, Robert N. Weinreb and Linda M. Zangwill

MARC

LEADER 00000caa a2200000 c 4500
001 181500665X
003 DE-627
005 20230427130735.0
007 cr uuu---uuuuu
008 220823s2022 xx |||||o 00| ||eng c
024 7 |a 10.3389/fmed.2022.872658  |2 doi 
035 |a (DE-627)181500665X 
035 |a (DE-599)KXP181500665X 
035 |a (OCoLC)1361713126 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rezapour, Jasmin  |d 1988-  |e VerfasserIn  |0 (DE-588)1074554957  |0 (DE-627)832289752  |0 (DE-576)442742959  |4 aut 
245 1 0 |a Comparison of optic disc ovality index and rotation angle measurements in myopic eyes using photography and OCT based techniques  |c Jasmin Rezapour, Andrew Q. Tran, Christopher Bowd, Nevin W. El-Nimri, Akram Belghith, Mark Christopher, Nicole Brye, James A. Proudfoot, Jade Dohleman, Massimo A. Fazio, Jost B. Jonas, Robert N. Weinreb and Linda M. Zangwill 
264 1 |c 24 June 2022 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 23.08.2022 
520 |a Purpose: To compare optic nerve head (ONH) ovality index and rotation angle measurements based on semi-automated delineation of the clinical ONH margin derived from photographs and automated BMO configuration derived from optical coherence tomography (OCT) images in healthy and glaucomatous eyes with high-, mild- and no axial myopia. - Methods: One hundred seventy-five healthy and glaucomatous eyes of 146 study participants enrolled in the Diagnostic Innovations in Glaucoma Study (DIGS) with optic disc photographs and Spectralis OCT ONH scans acquired on the same day were stratified by level of axial myopia (non-myopic [n = 56, axial length (AL) <24 mm], mild-myopic [n = 58, AL 24-26 mm] and high-myopic [n = 32, AL >26 mm]. The clinical disc margin of each photograph was manually annotated, and semi-automated measurements were recorded of the ovality index and rotation angle based on a best-fit ellipse generated using ImageJ software. These semi-automated photograph-based measurements were compared to ovality index and rotation angle generated from custom automated BMO-based analysis using segmented OCT ONH volumes. R 2 values from linear mixed effects models were used to describe the associations between semi-automated, photograph-based and automated OCT-based measurements. - Results: Average (95% CI) axial length was 23.3 (23.0, 23.3) mm, 24.8 (24.7, 25.0) mm and 26.8 (26.6, 27.0) mm in non-myopic, mild-myopic and high-myopic eyes, respectively (ANOVA, p ≤ 0.001 for all). The R 2 association (95% CI) between semi-automated photograph-based and automated OCT-based assessment of ONH OI for all eyes was [0.26 (0.16, 0.36); p < 0.001]. This association was weakest in non-myopic eyes [0.09 (0.01, 0.26); p = 0.02], followed by mild-myopic eyes [0.13 (0.02, 0.29); p = 0.004] and strongest in high-myopic eyes [0.40 (0.19, 0.60); p < 0.001]. No significant associations were found between photography- and OCT-based assessment of rotation angle with R 2 values ranging from 0.00 (0.00, 0.08) in non-myopic eyes to 0.03 (0.00, 0.21) in high-myopic eyes (all associations p ≥ 0.33). - Conclusions: Agreement between photograph-based and automated OCT-based ONH morphology measurements is limited, suggesting that these methods cannot be used interchangeably for characterizing myopic changes in the ONH. 
650 4 |a axial myopia 
650 4 |a Bruch's membrane opening 
650 4 |a clinical disc margin 
650 4 |a glaucoma 
650 4 |a high myopia 
650 4 |a OCT 
650 4 |a OCT landmarks 
650 4 |a optic nerve head morphology 
700 1 |a Tran, Andrew Q.  |e VerfasserIn  |4 aut 
700 1 |a Bowd, Christopher  |e VerfasserIn  |4 aut 
700 1 |a El-Nimri, Nevin W.  |e VerfasserIn  |4 aut 
700 1 |a Belghith, Akram  |e VerfasserIn  |4 aut 
700 1 |a Christopher, Mark  |e VerfasserIn  |4 aut 
700 1 |a Brye, Nicole  |e VerfasserIn  |4 aut 
700 1 |a Proudfoot, James A.  |e VerfasserIn  |4 aut 
700 1 |a Dohleman, Jade  |e VerfasserIn  |4 aut 
700 1 |a Fazio, Massimo A.  |e VerfasserIn  |4 aut 
700 1 |a Jonas, Jost B.  |d 1958-  |e VerfasserIn  |0 (DE-588)1028286732  |0 (DE-627)730536823  |0 (DE-576)37578537X  |4 aut 
700 1 |a Weinreb, Robert N.  |e VerfasserIn  |4 aut 
700 1 |a Zangwill, Linda M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Frontiers in medicine  |d Lausanne : Frontiers Media, 2014  |g 9(2022), Artikel-ID 872658, Seite 1-11  |h Online-Ressource  |w (DE-627)789482991  |w (DE-600)2775999-4  |w (DE-576)408729597  |x 2296-858X  |7 nnas  |a Comparison of optic disc ovality index and rotation angle measurements in myopic eyes using photography and OCT based techniques 
773 1 8 |g volume:9  |g year:2022  |g elocationid:872658  |g pages:1-11  |g extent:11  |a Comparison of optic disc ovality index and rotation angle measurements in myopic eyes using photography and OCT based techniques 
856 4 0 |u https://doi.org/10.3389/fmed.2022.872658  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220823 
993 |a Article 
994 |a 2022 
998 |g 1028286732  |a Jonas, Jost B.  |m 1028286732:Jonas, Jost B.  |d 60000  |e 60000PJ1028286732  |k 0/60000/  |p 11 
999 |a KXP-PPN181500665X  |e 4182298128 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"role":"aut","given":"Jasmin","family":"Rezapour","display":"Rezapour, Jasmin"},{"display":"Tran, Andrew Q.","family":"Tran","given":"Andrew Q.","role":"aut"},{"display":"Bowd, Christopher","family":"Bowd","given":"Christopher","role":"aut"},{"given":"Nevin W.","role":"aut","family":"El-Nimri","display":"El-Nimri, Nevin W."},{"display":"Belghith, Akram","family":"Belghith","given":"Akram","role":"aut"},{"display":"Christopher, Mark","family":"Christopher","given":"Mark","role":"aut"},{"display":"Brye, Nicole","family":"Brye","role":"aut","given":"Nicole"},{"display":"Proudfoot, James A.","family":"Proudfoot","role":"aut","given":"James A."},{"role":"aut","given":"Jade","display":"Dohleman, Jade","family":"Dohleman"},{"family":"Fazio","display":"Fazio, Massimo A.","role":"aut","given":"Massimo A."},{"display":"Jonas, Jost B.","family":"Jonas","role":"aut","given":"Jost B."},{"family":"Weinreb","display":"Weinreb, Robert N.","role":"aut","given":"Robert N."},{"display":"Zangwill, Linda M.","family":"Zangwill","role":"aut","given":"Linda M."}],"relHost":[{"part":{"volume":"9","extent":"11","text":"9(2022), Artikel-ID 872658, Seite 1-11","year":"2022","pages":"1-11"},"titleAlt":[{"title":"FMED"},{"title":"Front. Med."}],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Comparison of optic disc ovality index and rotation angle measurements in myopic eyes using photography and OCT based techniquesFrontiers in medicine","origin":[{"publisherPlace":"Lausanne","dateIssuedDisp":"2014-","dateIssuedKey":"2014","publisher":"Frontiers Media"}],"pubHistory":["2014 -"],"note":["Gesehen am 09.02.2021"],"title":[{"title_sort":"Frontiers in medicine","title":"Frontiers in medicine"}],"id":{"eki":["789482991"],"issn":["2296-858X"],"zdb":["2775999-4"]},"recId":"789482991","physDesc":[{"extent":"Online-Ressource"}]}],"recId":"181500665X","physDesc":[{"extent":"11 S."}],"name":{"displayForm":["Jasmin Rezapour, Andrew Q. Tran, Christopher Bowd, Nevin W. El-Nimri, Akram Belghith, Mark Christopher, Nicole Brye, James A. Proudfoot, Jade Dohleman, Massimo A. Fazio, Jost B. Jonas, Robert N. Weinreb and Linda M. Zangwill"]},"id":{"eki":["181500665X"],"doi":["10.3389/fmed.2022.872658"]},"title":[{"title":"Comparison of optic disc ovality index and rotation angle measurements in myopic eyes using photography and OCT based techniques","title_sort":"Comparison of optic disc ovality index and rotation angle measurements in myopic eyes using photography and OCT based techniques"}],"note":["Gesehen am 23.08.2022"],"origin":[{"dateIssuedDisp":"24 June 2022","dateIssuedKey":"2022"}],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a REZAPOURJACOMPARISON2420