Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis
PURPOSE: To compare image quality of an optimized diffusion weighted imaging (DWI) sequence with advanced post-processing and motion correction (advanced-EPI) to a standard DWI protocol (standard-EPI) in pancreatic imaging. - MATERIALS AND METHODS: 62 consecutive patients underwent abdominal MRI at...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2022
|
| In: |
Clinical imaging
Year: 2022, Jahrgang: 83, Pages: 33-40 |
| ISSN: | 1873-4499 |
| DOI: | 10.1016/j.clinimag.2021.11.033 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.clinimag.2021.11.033 |
| Verfasserangaben: | Anoshirwan Andrej Tavakoli, Constantin Dreher, Anna Mlynarska, Tristan Anselm Kuder, Regula Gnirs, Heinz-Peter Schlemmer, Sebastian Bickelhaupt |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1815401028 | ||
| 003 | DE-627 | ||
| 005 | 20240417193242.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220830s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.clinimag.2021.11.033 |2 doi | |
| 035 | |a (DE-627)1815401028 | ||
| 035 | |a (DE-599)KXP1815401028 | ||
| 035 | |a (OCoLC)1361696838 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Tavakoli, Andrej |d 1987- |e VerfasserIn |0 (DE-588)118568624X |0 (DE-627)1665044403 |4 aut | |
| 245 | 1 | 0 | |a Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis |c Anoshirwan Andrej Tavakoli, Constantin Dreher, Anna Mlynarska, Tristan Anselm Kuder, Regula Gnirs, Heinz-Peter Schlemmer, Sebastian Bickelhaupt |
| 264 | 1 | |c 2022 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 10 December 2021 | ||
| 500 | |a Gesehen am 30.08.2022 | ||
| 520 | |a PURPOSE: To compare image quality of an optimized diffusion weighted imaging (DWI) sequence with advanced post-processing and motion correction (advanced-EPI) to a standard DWI protocol (standard-EPI) in pancreatic imaging. - MATERIALS AND METHODS: 62 consecutive patients underwent abdominal MRI at 1.5 T were included in this retrospective analysis of data collected as part of an IRB approved study. All patients received a standard-EPI and an advanced-EPI DWI with advanced post-processing and motion correction. Two blinded radiologists evaluated the parameters image quality, detail of parenchyma, sharpness of boundaries and discernibility from adjacent structures on b = 900 s/mm2 images using a Likert-like scale. Segmentation of pancreatic head, body and tail were obtained and apparent diffusion coefficient (ADC) was calculated separately for each region. Apparent tissue-to-background ratio (TBR) was calculated at b = 50 s/mm2 and at b = 900 s/mm2. - RESULTS: The advanced-EPI yielded significantly higher scores for pancreatic parameters of image quality, detail level of parenchyma, sharpness of boundaries and discernibility from adjacent structures in comparison to standard-EPI (p < 0.001 for all, kappa = [0.46,0.71]) and was preferred in 96% of the cases when directly compared. ADC of the pancreas was 7% lower in advanced-EPI (1.236 ± 0.152 vs. 1.146 ± 0.126 μm2/ms, p < 0.001). ADC in the pancreatic tail was significantly lower for both sequences compared to head and body (all p < 0.001). There was comparable TBR for both sequences at b = 50 s/mm2 (standard-EPI: 19.0 ± 5.9 vs. advanced-EPI: 19.0 ± 6.4, p = 0.96), whereas at b = 900 s/mm2, TBR was 51% higher for advanced-EPI (standard-EPI: 7.1 ± 2.5 vs. advanced-EPI: 10.8 ± 5.1, p < 0.001). - CONCLUSION: An advanced DWI sequence might increase image quality for focused imaging of the pancreas and providing improved parenchymal detail levels compared to a standard DWI. | ||
| 650 | 4 | |a Artifacts | |
| 650 | 4 | |a Diffusion magnetic resonance imaging | |
| 650 | 4 | |a Diffusion Magnetic Resonance Imaging | |
| 650 | 4 | |a Echo-planar imaging | |
| 650 | 4 | |a Echo-Planar Imaging | |
| 650 | 4 | |a Humans | |
| 650 | 4 | |a Magnetic resonance imaging | |
| 650 | 4 | |a Pancreas | |
| 650 | 4 | |a Reproducibility of Results | |
| 650 | 4 | |a Retrospective Studies | |
| 700 | 1 | |a Dreher, Constantin |d 1991- |e VerfasserIn |0 (DE-588)1075340934 |0 (DE-627)833201387 |0 (DE-576)44340805X |4 aut | |
| 700 | 1 | |a Młynarska-Bujny, Anna |d 1990- |e VerfasserIn |0 (DE-588)1216974608 |0 (DE-627)1728639042 |4 aut | |
| 700 | 1 | |a Kuder, Tristan Anselm |e VerfasserIn |0 (DE-588)14203911X |0 (DE-627)704126338 |0 (DE-576)326749675 |4 aut | |
| 700 | 1 | |a Gnirs, Regula |e VerfasserIn |0 (DE-588)1230998284 |0 (DE-627)1753334381 |4 aut | |
| 700 | 1 | |a Schlemmer, Heinz-Peter |d 1961- |e VerfasserIn |0 (DE-588)1025559967 |0 (DE-627)722927142 |0 (DE-576)17334805X |4 aut | |
| 700 | 1 | |a Bickelhaupt, Sebastian |d 1984- |e VerfasserIn |0 (DE-588)1074040759 |0 (DE-627)83020668X |0 (DE-576)435548131 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Clinical imaging |d Amsterdam [u.a.] : Elsevier Science, 1989 |g 83(2022), Seite 33-40 |h Online-Ressource |w (DE-627)320437914 |w (DE-600)2004578-5 |w (DE-576)261857592 |x 1873-4499 |7 nnas |a Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis |
| 773 | 1 | 8 | |g volume:83 |g year:2022 |g pages:33-40 |g extent:8 |a Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.clinimag.2021.11.033 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220830 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 1074040759 |a Bickelhaupt, Sebastian |m 1074040759:Bickelhaupt, Sebastian |d 50000 |e 50000PB1074040759 |k 0/50000/ |p 7 |y j | ||
| 998 | |g 1025559967 |a Schlemmer, Heinz-Peter |m 1025559967:Schlemmer, Heinz-Peter |d 50000 |e 50000PS1025559967 |k 0/50000/ |p 6 | ||
| 998 | |g 14203911X |a Kuder, Tristan Anselm |m 14203911X:Kuder, Tristan Anselm |d 130000 |e 130000PK14203911X |k 0/130000/ |p 4 | ||
| 998 | |g 1216974608 |a Młynarska-Bujny, Anna |m 1216974608:Młynarska-Bujny, Anna |d 50000 |e 50000PM1216974608 |k 0/50000/ |p 3 | ||
| 998 | |g 1075340934 |a Dreher, Constantin |m 1075340934:Dreher, Constantin |d 60000 |d 63000 |e 60000PD1075340934 |e 63000PD1075340934 |k 0/60000/ |k 1/60000/63000/ |p 2 | ||
| 998 | |g 118568624X |a Tavakoli, Andrej |m 118568624X:Tavakoli, Andrej |d 50000 |e 50000PT118568624X |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1815401028 |e 4183692768 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"8 S."}],"person":[{"display":"Tavakoli, Andrej","role":"aut","family":"Tavakoli","given":"Andrej"},{"role":"aut","display":"Dreher, Constantin","given":"Constantin","family":"Dreher"},{"role":"aut","display":"Młynarska-Bujny, Anna","given":"Anna","family":"Młynarska-Bujny"},{"given":"Tristan Anselm","family":"Kuder","role":"aut","display":"Kuder, Tristan Anselm"},{"role":"aut","display":"Gnirs, Regula","family":"Gnirs","given":"Regula"},{"display":"Schlemmer, Heinz-Peter","role":"aut","given":"Heinz-Peter","family":"Schlemmer"},{"display":"Bickelhaupt, Sebastian","role":"aut","given":"Sebastian","family":"Bickelhaupt"}],"title":[{"title_sort":"Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis","title":"Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis"}],"relHost":[{"part":{"extent":"8","year":"2022","volume":"83","pages":"33-40","text":"83(2022), Seite 33-40"},"title":[{"title_sort":"Clinical imaging","title":"Clinical imaging"}],"disp":"Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysisClinical imaging","language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisher":"Elsevier Science","dateIssuedDisp":"1989-","dateIssuedKey":"1989","publisherPlace":"Amsterdam [u.a.]"}],"note":["Gesehen am 04.02.20"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"320437914","pubHistory":["13.1989 -"],"id":{"eki":["320437914"],"issn":["1873-4499"],"zdb":["2004578-5"]}}],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"2022"}],"note":["Available online 10 December 2021","Gesehen am 30.08.2022"],"id":{"eki":["1815401028"],"doi":["10.1016/j.clinimag.2021.11.033"]},"name":{"displayForm":["Anoshirwan Andrej Tavakoli, Constantin Dreher, Anna Mlynarska, Tristan Anselm Kuder, Regula Gnirs, Heinz-Peter Schlemmer, Sebastian Bickelhaupt"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"recId":"1815401028"} | ||
| SRT | |a TAVAKOLIANPANCREATIC2022 | ||