Development and verification of an adjustment factor for determining the axial length using optical biometry in silicone oil-filled eyes
The aim of this prospective clinical study was to establish and verify an adaptation for axial length (AL) measurement in silicone oil (SO)-filled pseudophakic eyes with a Scheimpflug and partial coherence interferometry (PCI)-based biometer. The AL was measured with a Pentacam AXL (OCULUS Optikgera...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
11 January 2022
|
| In: |
Diagnostics
Year: 2022, Jahrgang: 12, Heft: 1, Pages: 1-8 |
| ISSN: | 2075-4418 |
| DOI: | 10.3390/diagnostics12010163 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3390/diagnostics12010163 Verlag, lizenzpflichtig, Volltext: https://www.mdpi.com/2075-4418/12/1/163 |
| Verfasserangaben: | Gerd U. Auffarth, Tadas Naujokaitis, Louise Blöck, Anna Daghbashyan, Jan Meis, Victor A. Augustin, Ramin Khoramnia and Timur M. Yildirim |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1815957239 | ||
| 003 | DE-627 | ||
| 005 | 20230426132812.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220907s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3390/diagnostics12010163 |2 doi | |
| 035 | |a (DE-627)1815957239 | ||
| 035 | |a (DE-599)KXP1815957239 | ||
| 035 | |a (OCoLC)1361696646 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 245 | 1 | 0 | |a Development and verification of an adjustment factor for determining the axial length using optical biometry in silicone oil-filled eyes |c Gerd U. Auffarth, Tadas Naujokaitis, Louise Blöck, Anna Daghbashyan, Jan Meis, Victor A. Augustin, Ramin Khoramnia and Timur M. Yildirim |
| 264 | 1 | |c 11 January 2022 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 07.09.2022 | ||
| 520 | |a The aim of this prospective clinical study was to establish and verify an adaptation for axial length (AL) measurement in silicone oil (SO)-filled pseudophakic eyes with a Scheimpflug and partial coherence interferometry (PCI)-based biometer. The AL was measured with a Pentacam AXL (OCULUS Optikgeräte GmbH, Wetzler, Germany) and IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany). The coefficients of variation (CoV) and the mean systematic difference (95% confidence interval (CI)) between the devices were calculated. After implementing a setting for measuring AL in tamponaded eyes with a Pentacam based on data of 29 eyes, another 12 eyes were examined for verification. The mean AL obtained with the Pentacam was 25.53 ± 1.94 mm (range: 21.70 to 30.76 mm), and with IOLMaster, 24.73 ± 1.97 mm (ranged 20.84 to 29.92 mm), resulting in a mean offset of 0.80 ± 0.08 mm (95% CI: 0.77, 0.83 mm), p < 0.001. The AL values of both devices showed a strong linear correlation (r = 0.999). Verification data confirmed good agreement, with a statistically and clinically non-significant mean difference of 0.02 ± 0.04 (95% CI: −0.01, 0.05) mm, p = 0.134. We implemented a specific adaptation for obtaining reliable AL values in SO-filled eyes with the Pentacam AXL. | ||
| 650 | 4 | |a ocular biometry | |
| 650 | 4 | |a optical coherence tomography | |
| 650 | 4 | |a optical diagnosis | |
| 650 | 4 | |a partial coherence interferometry | |
| 650 | 4 | |a refractive outcome | |
| 650 | 4 | |a retinal disease | |
| 650 | 4 | |a Scheimpflug imaging | |
| 650 | 4 | |a treatment options | |
| 700 | 1 | |a Naujokaitis, Tadas |e VerfasserIn |0 (DE-588)1240859635 |0 (DE-627)1769941541 |4 aut | |
| 700 | 1 | |a Blöck, Louise |e VerfasserIn |0 (DE-588)1267495545 |0 (DE-627)1815958707 |4 aut | |
| 700 | 1 | |a Daghbashyan, Anna |e VerfasserIn |0 (DE-588)1267495979 |0 (DE-627)1815959606 |4 aut | |
| 700 | 1 | |a Meis, Jan |d 1992- |e VerfasserIn |0 (DE-588)1261856112 |0 (DE-627)180919900X |4 aut | |
| 700 | 1 | |a Augustin, Victor A. |d 1989- |e VerfasserIn |0 (DE-588)1179495500 |0 (DE-627)1067395164 |0 (DE-576)518265579 |4 aut | |
| 700 | 1 | |a Khoramnia, Ramin |d 1980- |e VerfasserIn |0 (DE-588)132573954 |0 (DE-627)523957173 |0 (DE-576)299234355 |4 aut | |
| 700 | 1 | |a Yildirim, Timur Mert |d 1990- |e VerfasserIn |0 (DE-588)112972557X |0 (DE-627)88437422X |0 (DE-576)486529894 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Diagnostics |d Basel : MDPI, 2011 |g 12(2022), 1, Artikel-ID 163, Seite 1-8 |h Online-Ressource |w (DE-627)718627814 |w (DE-600)2662336-5 |w (DE-576)365413917 |x 2075-4418 |7 nnas |a Development and verification of an adjustment factor for determining the axial length using optical biometry in silicone oil-filled eyes |
| 773 | 1 | 8 | |g volume:12 |g year:2022 |g number:1 |g elocationid:163 |g pages:1-8 |g extent:8 |a Development and verification of an adjustment factor for determining the axial length using optical biometry in silicone oil-filled eyes |
| 856 | 4 | 0 | |u https://doi.org/10.3390/diagnostics12010163 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.mdpi.com/2075-4418/12/1/163 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220907 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 112972557X |a Yildirim, Timur Mert |m 112972557X:Yildirim, Timur Mert |d 910000 |d 910900 |e 910000PY112972557X |e 910900PY112972557X |k 0/910000/ |k 1/910000/910900/ |p 8 |y j | ||
| 998 | |g 132573954 |a Khoramnia, Ramin |m 132573954:Khoramnia, Ramin |d 910000 |d 910900 |d 50000 |e 910000PK132573954 |e 910900PK132573954 |e 50000PK132573954 |k 0/910000/ |k 1/910000/910900/ |k 0/50000/ |p 7 | ||
| 998 | |g 1179495500 |a Augustin, Victor A. |m 1179495500:Augustin, Victor A. |d 910000 |d 910900 |e 910000PA1179495500 |e 910900PA1179495500 |k 0/910000/ |k 1/910000/910900/ |p 6 | ||
| 998 | |g 1261856112 |a Meis, Jan |m 1261856112:Meis, Jan |d 910000 |d 911800 |e 910000PM1261856112 |e 911800PM1261856112 |k 0/910000/ |k 1/910000/911800/ |p 5 | ||
| 998 | |g 1267495979 |a Daghbashyan, Anna |m 1267495979:Daghbashyan, Anna |d 910000 |d 910900 |e 910000PD1267495979 |e 910900PD1267495979 |k 0/910000/ |k 1/910000/910900/ |p 4 | ||
| 998 | |g 1267495545 |a Blöck, Louise |m 1267495545:Blöck, Louise |d 910000 |d 910900 |e 910000PB1267495545 |e 910900PB1267495545 |k 0/910000/ |k 1/910000/910900/ |p 3 | ||
| 998 | |g 1240859635 |a Naujokaitis, Tadas |m 1240859635:Naujokaitis, Tadas |d 910000 |d 910900 |e 910000PN1240859635 |e 910900PN1240859635 |k 0/910000/ |k 1/910000/910900/ |p 2 | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1815957239 |e 4185260946 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"note":["Gesehen am 07.09.2022"],"relHost":[{"title":[{"subtitle":"open access journal","title_sort":"Diagnostics","title":"Diagnostics"}],"disp":"Development and verification of an adjustment factor for determining the axial length using optical biometry in silicone oil-filled eyesDiagnostics","part":{"pages":"1-8","text":"12(2022), 1, Artikel-ID 163, Seite 1-8","year":"2022","volume":"12","extent":"8","issue":"1"},"id":{"zdb":["2662336-5"],"eki":["718627814"],"issn":["2075-4418"]},"origin":[{"dateIssuedDisp":"2011-","publisher":"MDPI","publisherPlace":"Basel","dateIssuedKey":"2011"}],"language":["eng"],"pubHistory":["1.2011 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28.05.2020"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"718627814"}],"recId":"1815957239","physDesc":[{"extent":"8 S."}],"name":{"displayForm":["Gerd U. Auffarth, Tadas Naujokaitis, Louise Blöck, Anna Daghbashyan, Jan Meis, Victor A. Augustin, Ramin Khoramnia and Timur M. Yildirim"]},"title":[{"title_sort":"Development and verification of an adjustment factor for determining the axial length using optical biometry in silicone oil-filled eyes","title":"Development and verification of an adjustment factor for determining the axial length using optical biometry in silicone oil-filled eyes"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"given":"Gerd U.","family":"Auffarth","display":"Auffarth, Gerd U.","role":"aut"},{"role":"aut","display":"Naujokaitis, Tadas","family":"Naujokaitis","given":"Tadas"},{"given":"Louise","family":"Blöck","role":"aut","display":"Blöck, Louise"},{"role":"aut","display":"Daghbashyan, Anna","family":"Daghbashyan","given":"Anna"},{"given":"Jan","role":"aut","display":"Meis, Jan","family":"Meis"},{"given":"Victor A.","role":"aut","display":"Augustin, Victor A.","family":"Augustin"},{"display":"Khoramnia, Ramin","role":"aut","family":"Khoramnia","given":"Ramin"},{"family":"Yildirim","role":"aut","display":"Yildirim, Timur Mert","given":"Timur Mert"}],"id":{"doi":["10.3390/diagnostics12010163"],"eki":["1815957239"]},"origin":[{"dateIssuedDisp":"11 January 2022","dateIssuedKey":"2022"}]} | ||
| SRT | |a AUFFARTHGEDEVELOPMEN1120 | ||