Intraocular lens power calculation after intrastromal femtosecond laser treatment for presbyopia: theoretic approach

PURPOSE: - To evaluate the accuracy of intraocular lens (IOL) power calculation after an intrastromal femtosecond laser procedure to treat presbyopia using a theoretic approach. - SETTING: - International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Hei...

Full description

Saved in:
Bibliographic Details
Main Authors: Rabsilber, Tanja Marina (Author) , Haigis, Wolfgang (Author) , Auffarth, Gerd U. (Author) , Mannsfeld, Annett (Author) , Ehmer, Angela (Author) , Holzer, Mike P. (Author)
Format: Article (Journal)
Language:English
Published: March 2011
In: Journal of cataract and refractive surgery
Year: 2011, Volume: 37, Issue: 3, Pages: 532-537
ISSN:1873-4502
DOI:10.1016/j.jcrs.2010.10.042
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcrs.2010.10.042
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/Abstract/2011/03000/Intraocular_lens_power_calculation_after.17.aspx
Get full text
Author Notes:Tanja M. Rabsilber, Wolfgang Haigis, Gerd U. Auffarth, Annett Mannsfeld, Angela Ehmer, Mike P. Holzer

MARC

LEADER 00000caa a22000002c 4500
001 1816279439
003 DE-627
005 20240417193436.0
007 cr uuu---uuuuu
008 220908s2011 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jcrs.2010.10.042  |2 doi 
035 |a (DE-627)1816279439 
035 |a (DE-599)KXP1816279439 
035 |a (OCoLC)1389792923 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rabsilber, Tanja Marina  |d 1977-  |e VerfasserIn  |0 (DE-588)128743271  |0 (DE-627)378689541  |0 (DE-576)297309609  |4 aut 
245 1 0 |a Intraocular lens power calculation after intrastromal femtosecond laser treatment for presbyopia  |b theoretic approach  |c Tanja M. Rabsilber, Wolfgang Haigis, Gerd U. Auffarth, Annett Mannsfeld, Angela Ehmer, Mike P. Holzer 
264 1 |c March 2011 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.09.2022 
520 |a PURPOSE: - To evaluate the accuracy of intraocular lens (IOL) power calculation after an intrastromal femtosecond laser procedure to treat presbyopia using a theoretic approach. - SETTING: - International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. - DESIGN: - Nonrandomized clinical trial. - METHODS: - Preoperatively and 12 months after intrastromal femtosecond laser treatment (IntraCor) of presbyopia, biometry was performed by partial coherence interferometry (PCI) (IOLMaster). The postoperative keratometry (K) values and IOL power calculation formulas (Holladay I, Haigis, SRK/T, Hoffer Q) were compared with results derived from the clinical history method, taking the manifest refraction change into account. - RESULTS: - The study enrolled 25 patients (median age 54 years). Three eyes were excluded for age-related lens changes. The median spherical equivalent change in the other 22 eyes was −0.38 diopter (D). The median difference in K values between the clinical history method and PCI was −0.21 D, resulting in a median IOL power difference between −0.23 D (SRK/T) and −0.29 D (Haigis) (range −1.58 to +1.00 D). The IOL power was underestimated in 59.1% of cases with the Hoffer Q and 63.6% of cases with the Holladay I, Haigis, and SRK/T. There was a difference of ±0.75 D in 72.7% of eyes using the Holladay I, Haigis, and Hoffer Q and in 86.4% of eyes using the SRK/T. Neither K values nor IOL power differences were statistically significant (P > .17). - CONCLUSION: - Intraocular lens power calculation using modern standard formulas incorporated in a PCI biometry device after intrastromal femtosecond presbyopia treatment was reliable, with minimum underestimation on average. 
700 1 |a Haigis, Wolfgang  |d 1947-2019  |e VerfasserIn  |0 (DE-588)119878668X  |0 (DE-627)1680966979  |4 aut 
700 1 |a Auffarth, Gerd U.  |d 1964-  |e VerfasserIn  |0 (DE-588)123385261  |0 (DE-627)577130420  |0 (DE-576)293687277  |4 aut 
700 1 |a Mannsfeld, Annett  |e VerfasserIn  |0 (DE-588)1255049332  |0 (DE-627)1798110830  |4 aut 
700 1 |a Ehmer, Angela  |e VerfasserIn  |0 (DE-588)1255048603  |0 (DE-627)1798109387  |4 aut 
700 1 |a Holzer, Mike P.  |d 1973-  |e VerfasserIn  |0 (DE-588)122217527  |0 (DE-627)705818640  |0 (DE-576)293157812  |4 aut 
773 0 8 |i Enthalten in  |t Journal of cataract and refractive surgery  |d Hagerstown, MD : Wolters Kluwer Health, 1986  |g 37(2011), 3, Seite 532-537  |h Online-Ressource  |w (DE-627)320594203  |w (DE-600)2019330-0  |w (DE-576)260773891  |x 1873-4502  |7 nnas  |a Intraocular lens power calculation after intrastromal femtosecond laser treatment for presbyopia theoretic approach 
773 1 8 |g volume:37  |g year:2011  |g number:3  |g pages:532-537  |g extent:6  |a Intraocular lens power calculation after intrastromal femtosecond laser treatment for presbyopia theoretic approach 
856 4 0 |u https://doi.org/10.1016/j.jcrs.2010.10.042  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/jcrs/Abstract/2011/03000/Intraocular_lens_power_calculation_after.17.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220908 
993 |a Article 
994 |a 2011 
998 |g 122217527  |a Holzer, Mike P.  |m 122217527:Holzer, Mike P.  |d 910000  |d 910900  |d 50000  |e 910000PH122217527  |e 910900PH122217527  |e 50000PH122217527  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 6  |y j 
998 |g 123385261  |a Auffarth, Gerd U.  |m 123385261:Auffarth, Gerd U.  |d 910000  |d 910900  |e 910000PA123385261  |e 910900PA123385261  |k 0/910000/  |k 1/910000/910900/  |p 3 
998 |g 128743271  |a Rabsilber, Tanja Marina  |m 128743271:Rabsilber, Tanja Marina  |d 910000  |d 910900  |e 910000PR128743271  |e 910900PR128743271  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1816279439  |e 4185774834 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"note":["Gesehen am 08.09.2022"],"recId":"1816279439","physDesc":[{"extent":"6 S."}],"relHost":[{"pubHistory":["12.1986 -"],"language":["eng"],"title":[{"title_sort":"Journal of cataract and refractive surgery","title":"Journal of cataract and refractive surgery"}],"disp":"Intraocular lens power calculation after intrastromal femtosecond laser treatment for presbyopia theoretic approachJournal of cataract and refractive surgery","name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"id":{"zdb":["2019330-0"],"issn":["1873-4502"],"eki":["320594203"]},"part":{"pages":"532-537","year":"2011","text":"37(2011), 3, Seite 532-537","extent":"6","volume":"37","issue":"3"},"origin":[{"dateIssuedDisp":"2020-","publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","dateIssuedKey":"2020"}],"note":["Gesehen am 02.08.24"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"320594203","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Journal of cataract & refractive surgery"}]}],"title":[{"subtitle":"theoretic approach","title":"Intraocular lens power calculation after intrastromal femtosecond laser treatment for presbyopia","title_sort":"Intraocular lens power calculation after intrastromal femtosecond laser treatment for presbyopia"}],"name":{"displayForm":["Tanja M. Rabsilber, Wolfgang Haigis, Gerd U. Auffarth, Annett Mannsfeld, Angela Ehmer, Mike P. Holzer"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"family":"Rabsilber","display":"Rabsilber, Tanja Marina","role":"aut","given":"Tanja Marina"},{"role":"aut","display":"Haigis, Wolfgang","family":"Haigis","given":"Wolfgang"},{"given":"Gerd U.","display":"Auffarth, Gerd U.","role":"aut","family":"Auffarth"},{"role":"aut","display":"Mannsfeld, Annett","family":"Mannsfeld","given":"Annett"},{"family":"Ehmer","role":"aut","display":"Ehmer, Angela","given":"Angela"},{"family":"Holzer","role":"aut","display":"Holzer, Mike P.","given":"Mike P."}],"id":{"doi":["10.1016/j.jcrs.2010.10.042"],"eki":["1816279439"]},"origin":[{"dateIssuedDisp":"March 2011","dateIssuedKey":"2011"}]} 
SRT |a RABSILBERTINTRAOCULA2011