Comparative study of application accuracy of two frameless neuronavigation systems: experimental error assessment quantifying registration methods and clinically influencing factors

This study aimed at comparing the accuracy of two commercial neuronavigation systems. Error assessment and quantification of clinical factors and surface registration, often resulting in decreased accuracy, were intended. Active (Stryker Navigation) and passive (VectorVision Sky, BrainLAB) neuronavi...

Full description

Saved in:
Bibliographic Details
Main Authors: Paraskevopoulos, Dimitrios (Author) , Unterberg, Andreas (Author) , Metzner, Roland (Author) , Dreyhaupt, Jens (Author) , Eggers, Georg (Author) , Wirtz, Christian Rainer (Author)
Format: Article (Journal)
Language:English
Published: 19 January 2011
In: Neurosurgical review
Year: 2011, Volume: 34, Issue: 2, Pages: 217-228
ISSN:1437-2320
DOI:10.1007/s10143-010-0302-5
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s10143-010-0302-5
Get full text
Author Notes:Dimitrios Paraskevopoulos, Andreas Unterberg, Roland Metzner, Jens Dreyhaupt, Georg Eggers, Christian Rainer Wirtz

MARC

LEADER 00000caa a2200000 c 4500
001 1816292117
003 DE-627
005 20230710120254.0
007 cr uuu---uuuuu
008 220908s2011 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10143-010-0302-5  |2 doi 
035 |a (DE-627)1816292117 
035 |a (DE-599)KXP1816292117 
035 |a (OCoLC)1389792166 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Paraskevopoulos, Dimitrios  |d 1976-  |e VerfasserIn  |0 (DE-588)138295727  |0 (DE-627)601105745  |0 (DE-576)307065553  |4 aut 
245 1 0 |a Comparative study of application accuracy of two frameless neuronavigation systems  |b experimental error assessment quantifying registration methods and clinically influencing factors  |c Dimitrios Paraskevopoulos, Andreas Unterberg, Roland Metzner, Jens Dreyhaupt, Georg Eggers, Christian Rainer Wirtz 
264 1 |c 19 January 2011 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.09.2022 
520 |a This study aimed at comparing the accuracy of two commercial neuronavigation systems. Error assessment and quantification of clinical factors and surface registration, often resulting in decreased accuracy, were intended. Active (Stryker Navigation) and passive (VectorVision Sky, BrainLAB) neuronavigation systems were tested with an anthropomorphic phantom with a deformable layer, simulating skin and soft tissue. True coordinates measured by computer numerical control were compared with coordinates on image data and during navigation, to calculate software and system accuracy respectively. Comparison of image and navigation coordinates was used to evaluate navigation accuracy. Both systems achieved an overall accuracy of <1.5 mm. Stryker achieved better software accuracy, whereas BrainLAB better system and navigation accuracy. Factors with conspicuous influence (P<0.01) were imaging, instrument replacement, sterile cover drape and geometry of instruments. Precision data indicated by the systems did not reflect measured accuracy in general. Surface matching resulted in no improvement of accuracy, confirming former studies. Laser registration showed no differences compared to conventional pointers. Differences between the two systems were limited. Surface registration may improve inaccurate point-based registrations but does not in general affect overall accuracy. Accuracy feedback by the systems does not always match with true target accuracy and requires critical evaluation from the surgeon. 
650 4 |a Computers 
650 4 |a Data Display 
650 4 |a Humans 
650 4 |a Image Processing, Computer-Assisted 
650 4 |a Magnetic Resonance Imaging 
650 4 |a Neuronavigation 
650 4 |a Neurosurgical Procedures 
650 4 |a Phantoms, Imaging 
650 4 |a Reproducibility of Results 
650 4 |a Signal Processing, Computer-Assisted 
650 4 |a Software 
650 4 |a Surgery, Computer-Assisted 
650 4 |a Tomography, X-Ray Computed 
700 1 |a Unterberg, Andreas  |e VerfasserIn  |0 (DE-588)1032681187  |0 (DE-627)738641200  |0 (DE-576)168441233  |4 aut 
700 1 |a Metzner, Roland  |d 1968-  |e VerfasserIn  |0 (DE-588)129843725  |0 (DE-627)481951083  |0 (DE-576)297864777  |4 aut 
700 1 |a Dreyhaupt, Jens  |e VerfasserIn  |0 (DE-588)1205936653  |0 (DE-627)1691776017  |4 aut 
700 1 |a Eggers, Georg  |d 1968-  |e VerfasserIn  |0 (DE-588)129307424  |0 (DE-627)39261779X  |0 (DE-576)293769095  |4 aut 
700 1 |a Wirtz, Christian Rainer  |d 1961-  |e VerfasserIn  |0 (DE-588)172531586  |0 (DE-627)697467783  |0 (DE-576)133391760  |4 aut 
773 0 8 |i Enthalten in  |t Neurosurgical review  |d Berlin : Springer, 1978  |g 34(2011), 2, Seite 217-228  |h Online-Ressource  |w (DE-627)269533133  |w (DE-600)1474861-7  |w (DE-576)080987060  |x 1437-2320  |7 nnas  |a Comparative study of application accuracy of two frameless neuronavigation systems experimental error assessment quantifying registration methods and clinically influencing factors 
773 1 8 |g volume:34  |g year:2011  |g number:2  |g pages:217-228  |g extent:12  |a Comparative study of application accuracy of two frameless neuronavigation systems experimental error assessment quantifying registration methods and clinically influencing factors 
856 4 0 |u https://doi.org/10.1007/s10143-010-0302-5  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220908 
993 |a Article 
994 |a 2011 
998 |g 129307424  |a Eggers, Georg  |m 129307424:Eggers, Georg  |d 910000  |d 910800  |e 910000PE129307424  |e 910800PE129307424  |k 0/910000/  |k 1/910000/910800/  |p 5 
998 |g 1205936653  |a Dreyhaupt, Jens  |m 1205936653:Dreyhaupt, Jens  |p 4 
998 |g 129843725  |a Metzner, Roland  |m 129843725:Metzner, Roland  |d 910000  |d 999701  |e 910000PM129843725  |e 999701PM129843725  |k 0/910000/  |k 1/910000/999701/  |p 3 
998 |g 1032681187  |a Unterberg, Andreas  |m 1032681187:Unterberg, Andreas  |d 910000  |d 911200  |e 910000PU1032681187  |e 911200PU1032681187  |k 0/910000/  |k 1/910000/911200/  |p 2 
999 |a KXP-PPN1816292117  |e 4185809557 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"12 S."}],"language":["eng"],"id":{"doi":["10.1007/s10143-010-0302-5"],"eki":["1816292117"]},"recId":"1816292117","name":{"displayForm":["Dimitrios Paraskevopoulos, Andreas Unterberg, Roland Metzner, Jens Dreyhaupt, Georg Eggers, Christian Rainer Wirtz"]},"relHost":[{"id":{"zdb":["1474861-7"],"issn":["1437-2320"],"eki":["269533133"]},"recId":"269533133","language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"disp":"Comparative study of application accuracy of two frameless neuronavigation systems experimental error assessment quantifying registration methods and clinically influencing factorsNeurosurgical review","part":{"extent":"12","pages":"217-228","volume":"34","text":"34(2011), 2, Seite 217-228","issue":"2","year":"2011"},"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"dateIssuedDisp":"1978-","publisher":"Springer","publisherPlace":"Berlin ; Heidelberg ; New York","dateIssuedKey":"1978"}],"title":[{"title":"Neurosurgical review","title_sort":"Neurosurgical review"}],"pubHistory":["1.1978 -"],"note":["Gesehen am 24.11.05","Fortsetzung der Druck-Ausgabe"]}],"note":["Gesehen am 08.09.2022"],"title":[{"subtitle":"experimental error assessment quantifying registration methods and clinically influencing factors","title_sort":"Comparative study of application accuracy of two frameless neuronavigation systems","title":"Comparative study of application accuracy of two frameless neuronavigation systems"}],"person":[{"display":"Paraskevopoulos, Dimitrios","family":"Paraskevopoulos","given":"Dimitrios","role":"aut"},{"display":"Unterberg, Andreas","given":"Andreas","family":"Unterberg","role":"aut"},{"role":"aut","given":"Roland","family":"Metzner","display":"Metzner, Roland"},{"role":"aut","display":"Dreyhaupt, Jens","family":"Dreyhaupt","given":"Jens"},{"role":"aut","display":"Eggers, Georg","family":"Eggers","given":"Georg"},{"role":"aut","display":"Wirtz, Christian Rainer","family":"Wirtz","given":"Christian Rainer"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"19 January 2011","dateIssuedKey":"2011"}]} 
SRT |a PARASKEVOPCOMPARATIV1920