Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components
Background - It has been proposed that bone mineral density has an influence on cement penetration in hip and knee arthroplasty. The hypotheses of this study were that: 1) there is a negative correlation between bone mineral density (BMD) and cement penetration in cemented glenoid components; and 2)...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2011
|
| In: |
Journal of shoulder and elbow surgery
Year: 2011, Jahrgang: 20, Heft: 5, Pages: 723-731 |
| ISSN: | 1532-6500 |
| DOI: | 10.1016/j.jse.2010.09.006 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jse.2010.09.006 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1058274610004064 |
| Verfasserangaben: | Patric Raiss, Guido Pape, Kerstin Kleinschmidt, Sebastian Jäger, Boris Sowa, Eike Jakubowitz, Markus Loew, Thomas Bruckner, Markus Rickert |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1816343919 | ||
| 003 | DE-627 | ||
| 005 | 20230710120131.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 220909s2011 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jse.2010.09.006 |2 doi | |
| 035 | |a (DE-627)1816343919 | ||
| 035 | |a (DE-599)KXP1816343919 | ||
| 035 | |a (OCoLC)1389791430 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Raiss, Patric |d 1977- |e VerfasserIn |0 (DE-588)134112660 |0 (DE-627)560887086 |0 (DE-576)278239803 |4 aut | |
| 245 | 1 | 0 | |a Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components |c Patric Raiss, Guido Pape, Kerstin Kleinschmidt, Sebastian Jäger, Boris Sowa, Eike Jakubowitz, Markus Loew, Thomas Bruckner, Markus Rickert |
| 264 | 1 | |c 2011 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Available online 30 December 2010 | ||
| 500 | |a Gesehen am 09.09.2022 | ||
| 520 | |a Background - It has been proposed that bone mineral density has an influence on cement penetration in hip and knee arthroplasty. The hypotheses of this study were that: 1) there is a negative correlation between bone mineral density (BMD) and cement penetration in cemented glenoid components; and 2) that implant design has an influence on cement penetration into the glenoid bone. - Methods - BMD of 10 pairs of fresh frozen scapulas was measured. Micro-computed tomography (micro-CT) scans in 3 different sections were analyzed after implantation of keeled and pegged glenoid components using a 3rd-generation cementing technique with a vacuum mixing system. Cement penetration was analyzed and correlated with BMD. Pull-out strength testing was performed to analyze primary stability. - Results - The overall peak BMD was 0.6 [g/cm2] (range, 0.33-0.98). A strong negative correlation between BMD and mean cement penetration was found for the peg (R2 = −.83; P < .003) and for the keel group (R2 = −.81; P < .005). Mean cement penetration was 78.4 mm2 (range, 60.6-94.2) in the keel and 113.9 mm2 (range, 78.2-143.4) in the peg group (P < .0001). In all cases, the components were pulled out of the cement mantle, whereas the bone-cement interfaces remained intact. The mean pull-out strength was 1093N (764-1343N) for keeled and 884N (650-1264N) for pegged components (P < .05). - Conclusion - A modern cementing technique, leading to a deep bonding between bone and cement, is crucial to prevent loosening of glenoid components. The findings of this study might help us to better understand the results of follow-up studies of cemented glenoid implants. Our results could be helpful for the choice of implants in patients with poor bone quality like osteoporosis or rheumatoid arthritis. | ||
| 650 | 4 | |a arthroplasty | |
| 650 | 4 | |a bone mineral density | |
| 650 | 4 | |a micro-CT | |
| 650 | 4 | |a shoulder | |
| 650 | 4 | |a TSA | |
| 700 | 1 | |a Pape, Guido |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kleinschmidt, Kerstin |e VerfasserIn |4 aut | |
| 700 | 1 | |a Jäger, Sebastian |d 1975- |e VerfasserIn |0 (DE-588)1059313731 |0 (DE-627)79828238X |0 (DE-576)415306647 |4 aut | |
| 700 | 1 | |a Sowa, Boris |d 1985- |e VerfasserIn |0 (DE-588)1044747714 |0 (DE-627)772652155 |0 (DE-576)398110611 |4 aut | |
| 700 | 1 | |a Jakubowitz, Eike |e VerfasserIn |4 aut | |
| 700 | 1 | |a Loew, Markus |d 1956- |e VerfasserIn |0 (DE-588)1076601375 |0 (DE-627)835112195 |0 (DE-576)164670610 |4 aut | |
| 700 | 1 | |a Bruckner, Thomas |d 1956- |e VerfasserIn |0 (DE-588)136046215 |0 (DE-627)574429298 |0 (DE-576)300798768 |4 aut | |
| 700 | 1 | |a Rickert, Markus |d 1968- |e VerfasserIn |0 (DE-588)118127179 |0 (DE-627)694693375 |0 (DE-576)291729185 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of shoulder and elbow surgery |d St. Louis, Mo. : Mosby, 1992 |g 20(2011), 5, Seite 723-731 |h Online-Ressource |w (DE-627)32927029X |w (DE-600)2046901-9 |w (DE-576)09442716X |x 1532-6500 |7 nnas |a Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components |
| 773 | 1 | 8 | |g volume:20 |g year:2011 |g number:5 |g pages:723-731 |g extent:9 |a Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jse.2010.09.006 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S1058274610004064 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20220909 | ||
| 993 | |a Article | ||
| 994 | |a 2011 | ||
| 998 | |g 118127179 |a Rickert, Markus |m 118127179:Rickert, Markus |d 50000 |e 50000PR118127179 |k 0/50000/ |p 9 |y j | ||
| 998 | |g 136046215 |a Bruckner, Thomas |m 136046215:Bruckner, Thomas |d 910000 |d 999701 |e 910000PB136046215 |e 999701PB136046215 |k 0/910000/ |k 1/910000/999701/ |p 8 | ||
| 998 | |g 1076601375 |a Loew, Markus |m 1076601375:Loew, Markus |d 50000 |e 50000PL1076601375 |k 0/50000/ |p 7 | ||
| 998 | |g 1044747714 |a Sowa, Boris |m 1044747714:Sowa, Boris |p 5 | ||
| 998 | |g 1059313731 |a Jäger, Sebastian |m 1059313731:Jäger, Sebastian |d 910000 |d 911460 |e 910000PJ1059313731 |e 911460PJ1059313731 |k 0/910000/ |k 1/910000/911460/ |p 4 | ||
| 998 | |g 134112660 |a Raiss, Patric |m 134112660:Raiss, Patric |d 910000 |d 911460 |e 910000PR134112660 |e 911460PR134112660 |k 0/910000/ |k 1/910000/911460/ |p 1 |x j | ||
| 999 | |a KXP-PPN1816343919 |e 4186302782 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011"}],"id":{"eki":["1816343919"],"doi":["10.1016/j.jse.2010.09.006"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"display":"Raiss, Patric","family":"Raiss","given":"Patric","role":"aut"},{"role":"aut","given":"Guido","family":"Pape","display":"Pape, Guido"},{"display":"Kleinschmidt, Kerstin","family":"Kleinschmidt","given":"Kerstin","role":"aut"},{"role":"aut","family":"Jäger","display":"Jäger, Sebastian","given":"Sebastian"},{"role":"aut","given":"Boris","display":"Sowa, Boris","family":"Sowa"},{"family":"Jakubowitz","display":"Jakubowitz, Eike","given":"Eike","role":"aut"},{"given":"Markus","family":"Loew","display":"Loew, Markus","role":"aut"},{"given":"Thomas","family":"Bruckner","display":"Bruckner, Thomas","role":"aut"},{"given":"Markus","display":"Rickert, Markus","family":"Rickert","role":"aut"}],"title":[{"title_sort":"Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components","title":"Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components"}],"physDesc":[{"extent":"9 S."}],"relHost":[{"note":["Gesehen am 19.02.20"],"pubHistory":["1.1992 -"],"recId":"32927029X","disp":"Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid componentsJournal of shoulder and elbow surgery","part":{"volume":"20","text":"20(2011), 5, Seite 723-731","pages":"723-731","extent":"9","year":"2011","issue":"5"},"title":[{"title":"Journal of shoulder and elbow surgery","title_sort":"Journal of shoulder and elbow surgery"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Mosby","dateIssuedKey":"1992","publisherPlace":"St. Louis, Mo.","dateIssuedDisp":"1992-"}],"id":{"eki":["32927029X"],"zdb":["2046901-9"],"issn":["1532-6500"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"name":{"displayForm":["Patric Raiss, Guido Pape, Kerstin Kleinschmidt, Sebastian Jäger, Boris Sowa, Eike Jakubowitz, Markus Loew, Thomas Bruckner, Markus Rickert"]},"note":["Available online 30 December 2010","Gesehen am 09.09.2022"],"recId":"1816343919"} | ||
| SRT | |a RAISSPATRIBONECEMENT2011 | ||