Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components

Background - It has been proposed that bone mineral density has an influence on cement penetration in hip and knee arthroplasty. The hypotheses of this study were that: 1) there is a negative correlation between bone mineral density (BMD) and cement penetration in cemented glenoid components; and 2)...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Raiss, Patric (VerfasserIn) , Pape, Guido (VerfasserIn) , Kleinschmidt, Kerstin (VerfasserIn) , Jäger, Sebastian (VerfasserIn) , Sowa, Boris (VerfasserIn) , Jakubowitz, Eike (VerfasserIn) , Loew, Markus (VerfasserIn) , Bruckner, Thomas (VerfasserIn) , Rickert, Markus (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2011
In: Journal of shoulder and elbow surgery
Year: 2011, Jahrgang: 20, Heft: 5, Pages: 723-731
ISSN:1532-6500
DOI:10.1016/j.jse.2010.09.006
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jse.2010.09.006
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1058274610004064
Volltext
Verfasserangaben:Patric Raiss, Guido Pape, Kerstin Kleinschmidt, Sebastian Jäger, Boris Sowa, Eike Jakubowitz, Markus Loew, Thomas Bruckner, Markus Rickert

MARC

LEADER 00000caa a2200000 c 4500
001 1816343919
003 DE-627
005 20230710120131.0
007 cr uuu---uuuuu
008 220909s2011 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jse.2010.09.006  |2 doi 
035 |a (DE-627)1816343919 
035 |a (DE-599)KXP1816343919 
035 |a (OCoLC)1389791430 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Raiss, Patric  |d 1977-  |e VerfasserIn  |0 (DE-588)134112660  |0 (DE-627)560887086  |0 (DE-576)278239803  |4 aut 
245 1 0 |a Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components  |c Patric Raiss, Guido Pape, Kerstin Kleinschmidt, Sebastian Jäger, Boris Sowa, Eike Jakubowitz, Markus Loew, Thomas Bruckner, Markus Rickert 
264 1 |c 2011 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 30 December 2010 
500 |a Gesehen am 09.09.2022 
520 |a Background - It has been proposed that bone mineral density has an influence on cement penetration in hip and knee arthroplasty. The hypotheses of this study were that: 1) there is a negative correlation between bone mineral density (BMD) and cement penetration in cemented glenoid components; and 2) that implant design has an influence on cement penetration into the glenoid bone. - Methods - BMD of 10 pairs of fresh frozen scapulas was measured. Micro-computed tomography (micro-CT) scans in 3 different sections were analyzed after implantation of keeled and pegged glenoid components using a 3rd-generation cementing technique with a vacuum mixing system. Cement penetration was analyzed and correlated with BMD. Pull-out strength testing was performed to analyze primary stability. - Results - The overall peak BMD was 0.6 [g/cm2] (range, 0.33-0.98). A strong negative correlation between BMD and mean cement penetration was found for the peg (R2 = −.83; P < .003) and for the keel group (R2 = −.81; P < .005). Mean cement penetration was 78.4 mm2 (range, 60.6-94.2) in the keel and 113.9 mm2 (range, 78.2-143.4) in the peg group (P < .0001). In all cases, the components were pulled out of the cement mantle, whereas the bone-cement interfaces remained intact. The mean pull-out strength was 1093N (764-1343N) for keeled and 884N (650-1264N) for pegged components (P < .05). - Conclusion - A modern cementing technique, leading to a deep bonding between bone and cement, is crucial to prevent loosening of glenoid components. The findings of this study might help us to better understand the results of follow-up studies of cemented glenoid implants. Our results could be helpful for the choice of implants in patients with poor bone quality like osteoporosis or rheumatoid arthritis. 
650 4 |a arthroplasty 
650 4 |a bone mineral density 
650 4 |a micro-CT 
650 4 |a shoulder 
650 4 |a TSA 
700 1 |a Pape, Guido  |e VerfasserIn  |4 aut 
700 1 |a Kleinschmidt, Kerstin  |e VerfasserIn  |4 aut 
700 1 |a Jäger, Sebastian  |d 1975-  |e VerfasserIn  |0 (DE-588)1059313731  |0 (DE-627)79828238X  |0 (DE-576)415306647  |4 aut 
700 1 |a Sowa, Boris  |d 1985-  |e VerfasserIn  |0 (DE-588)1044747714  |0 (DE-627)772652155  |0 (DE-576)398110611  |4 aut 
700 1 |a Jakubowitz, Eike  |e VerfasserIn  |4 aut 
700 1 |a Loew, Markus  |d 1956-  |e VerfasserIn  |0 (DE-588)1076601375  |0 (DE-627)835112195  |0 (DE-576)164670610  |4 aut 
700 1 |a Bruckner, Thomas  |d 1956-  |e VerfasserIn  |0 (DE-588)136046215  |0 (DE-627)574429298  |0 (DE-576)300798768  |4 aut 
700 1 |a Rickert, Markus  |d 1968-  |e VerfasserIn  |0 (DE-588)118127179  |0 (DE-627)694693375  |0 (DE-576)291729185  |4 aut 
773 0 8 |i Enthalten in  |t Journal of shoulder and elbow surgery  |d St. Louis, Mo. : Mosby, 1992  |g 20(2011), 5, Seite 723-731  |h Online-Ressource  |w (DE-627)32927029X  |w (DE-600)2046901-9  |w (DE-576)09442716X  |x 1532-6500  |7 nnas  |a Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components 
773 1 8 |g volume:20  |g year:2011  |g number:5  |g pages:723-731  |g extent:9  |a Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components 
856 4 0 |u https://doi.org/10.1016/j.jse.2010.09.006  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1058274610004064  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220909 
993 |a Article 
994 |a 2011 
998 |g 118127179  |a Rickert, Markus  |m 118127179:Rickert, Markus  |d 50000  |e 50000PR118127179  |k 0/50000/  |p 9  |y j 
998 |g 136046215  |a Bruckner, Thomas  |m 136046215:Bruckner, Thomas  |d 910000  |d 999701  |e 910000PB136046215  |e 999701PB136046215  |k 0/910000/  |k 1/910000/999701/  |p 8 
998 |g 1076601375  |a Loew, Markus  |m 1076601375:Loew, Markus  |d 50000  |e 50000PL1076601375  |k 0/50000/  |p 7 
998 |g 1044747714  |a Sowa, Boris  |m 1044747714:Sowa, Boris  |p 5 
998 |g 1059313731  |a Jäger, Sebastian  |m 1059313731:Jäger, Sebastian  |d 910000  |d 911460  |e 910000PJ1059313731  |e 911460PJ1059313731  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 134112660  |a Raiss, Patric  |m 134112660:Raiss, Patric  |d 910000  |d 911460  |e 910000PR134112660  |e 911460PR134112660  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1816343919  |e 4186302782 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011"}],"id":{"eki":["1816343919"],"doi":["10.1016/j.jse.2010.09.006"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"person":[{"display":"Raiss, Patric","family":"Raiss","given":"Patric","role":"aut"},{"role":"aut","given":"Guido","family":"Pape","display":"Pape, Guido"},{"display":"Kleinschmidt, Kerstin","family":"Kleinschmidt","given":"Kerstin","role":"aut"},{"role":"aut","family":"Jäger","display":"Jäger, Sebastian","given":"Sebastian"},{"role":"aut","given":"Boris","display":"Sowa, Boris","family":"Sowa"},{"family":"Jakubowitz","display":"Jakubowitz, Eike","given":"Eike","role":"aut"},{"given":"Markus","family":"Loew","display":"Loew, Markus","role":"aut"},{"given":"Thomas","family":"Bruckner","display":"Bruckner, Thomas","role":"aut"},{"given":"Markus","display":"Rickert, Markus","family":"Rickert","role":"aut"}],"title":[{"title_sort":"Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components","title":"Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components"}],"physDesc":[{"extent":"9 S."}],"relHost":[{"note":["Gesehen am 19.02.20"],"pubHistory":["1.1992 -"],"recId":"32927029X","disp":"Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid componentsJournal of shoulder and elbow surgery","part":{"volume":"20","text":"20(2011), 5, Seite 723-731","pages":"723-731","extent":"9","year":"2011","issue":"5"},"title":[{"title":"Journal of shoulder and elbow surgery","title_sort":"Journal of shoulder and elbow surgery"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Mosby","dateIssuedKey":"1992","publisherPlace":"St. Louis, Mo.","dateIssuedDisp":"1992-"}],"id":{"eki":["32927029X"],"zdb":["2046901-9"],"issn":["1532-6500"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"name":{"displayForm":["Patric Raiss, Guido Pape, Kerstin Kleinschmidt, Sebastian Jäger, Boris Sowa, Eike Jakubowitz, Markus Loew, Thomas Bruckner, Markus Rickert"]},"note":["Available online 30 December 2010","Gesehen am 09.09.2022"],"recId":"1816343919"} 
SRT |a RAISSPATRIBONECEMENT2011