Computer-based liver volumetry in the liver perfusion simulator

Background - An exact preoperative liver volume calculation is important prior to liver surgery and living-related liver transplantation. However, CT or MRI assessment of preoperative liver volume is associated with an estimation error of 1.2% to 36%, and little data is available on its accuracy on...

Full description

Saved in:
Bibliographic Details
Main Authors: Müller, Sascha A. (Author) , Pianka, Frank (Author) , Schöbinger, Maximilian (Author) , Mehrabi, Arianeb (Author) , Fonouni, Hamidreza (Author) , Radeleff, Boris (Author) , Meinzer, Hans-Peter (Author) , Schmied, Bruno (Author)
Format: Article (Journal)
Language:English
Published: 2011
In: Journal of surgical research
Year: 2011, Volume: 171, Issue: 1, Pages: 87-93
ISSN:1095-8673
DOI:10.1016/j.jss.2010.02.038
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jss.2010.02.038
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0022480410001629
Get full text
Author Notes:Sascha Arian Müller, M.D., Frank Pianka, M.D., Max Schöbinger, Arianeb Mehrabi, M.D., Hamid Fonouni, M.D., Boris Radeleff, M.D., Hans-Peter Meinzer, Prof., and Bruno M. Schmied, M.D.

MARC

LEADER 00000caa a2200000 c 4500
001 1816642754
003 DE-627
005 20230710115444.0
007 cr uuu---uuuuu
008 220914s2011 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jss.2010.02.038  |2 doi 
035 |a (DE-627)1816642754 
035 |a (DE-599)KXP1816642754 
035 |a (OCoLC)1389790156 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Müller, Sascha A.  |d 1976-  |e VerfasserIn  |0 (DE-588)1021104795  |0 (DE-627)691459525  |0 (DE-576)358875757  |4 aut 
245 1 0 |a Computer-based liver volumetry in the liver perfusion simulator  |c Sascha Arian Müller, M.D., Frank Pianka, M.D., Max Schöbinger, Arianeb Mehrabi, M.D., Hamid Fonouni, M.D., Boris Radeleff, M.D., Hans-Peter Meinzer, Prof., and Bruno M. Schmied, M.D. 
264 1 |c 2011 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published online: 20 March 2010 
500 |a Gesehen am 14.09.2022 
520 |a Background - An exact preoperative liver volume calculation is important prior to liver surgery and living-related liver transplantation. However, CT or MRI assessment of preoperative liver volume is associated with an estimation error of 1.2% to 36%, and little data is available on its accuracy on the segmental level. The aim of this study was to validate arterial and portal venous flow rates and gain information on liver volumetry, including liver segments, in the liver perfusion simulator and compare it to in vivo measurements in a porcine model. - Material and Methods - The arterial and portal venous flow rates and liver volumes of 10 pigs were measured in vivo and compared with the flow rates and volumes ex vivo. CT scans were performed and the volume of the liver and its lobes calculated by water displacement or computer-assistance based on the CT scans. The right lateral lobe was plasticized and reconstructed for the volume calculation. - Results - In the liver perfusion simulator, arterial and portal venous flow rates comparable to the in vivo rates were achieved. The liver volume had a mean difference of 10.3% between in vivo and ex vivo measurements. In the liver perfusion simulator, the mean deviation in liver volume between the computer calculation and water displacement was 2.8%. On the segmental level, the Heidelberg algorithm provided an accuracy of 97.7%. - Conclusion - The liver perfusion simulator is an excellent device for studies in liver perfusion and volumetry. Furthermore, the simulator is applicable for teaching and performing interventions and surgeries in livers. 
650 4 |a Heidelberg algorithm 
650 4 |a liver interventions 
650 4 |a liver perfusion 
650 4 |a liver perfusion simulator 
650 4 |a liver volumetry 
650 4 |a multislice CT scan 
700 1 |a Pianka, Frank  |d 1985-  |e VerfasserIn  |0 (DE-588)1047089793  |0 (DE-627)777548925  |0 (DE-576)40040009X  |4 aut 
700 1 |a Schöbinger, Maximilian  |d 1977-  |e VerfasserIn  |0 (DE-588)137850204  |0 (DE-627)596148291  |0 (DE-576)304914991  |4 aut 
700 1 |a Mehrabi, Arianeb  |d 1967-  |e VerfasserIn  |0 (DE-588)137664583  |0 (DE-627)594829763  |0 (DE-576)304831263  |4 aut 
700 1 |a Fonouni, Hamidreza  |e VerfasserIn  |0 (DE-588)1065677154  |0 (DE-627)816553769  |0 (DE-576)425366707  |4 aut 
700 1 |a Radeleff, Boris  |d 1969-  |e VerfasserIn  |0 (DE-588)123910846  |0 (DE-627)706470826  |0 (DE-576)293938504  |4 aut 
700 1 |a Meinzer, Hans-Peter  |d 1948-2023  |e VerfasserIn  |0 (DE-588)10927279X  |0 (DE-627)516177990  |0 (DE-576)289636914  |4 aut 
700 1 |a Schmied, Bruno  |e VerfasserIn  |0 (DE-588)1026855721  |0 (DE-627)727503944  |0 (DE-576)372188486  |4 aut 
773 0 8 |i Enthalten in  |t Journal of surgical research  |d Orlando, Fla. : Academic Press, 1961  |g 171(2011), 1 vom: Nov., Seite 87-93  |h Online-Ressource  |w (DE-627)267836821  |w (DE-600)1470806-1  |w (DE-576)104193948  |x 1095-8673  |7 nnas  |a Computer-based liver volumetry in the liver perfusion simulator 
773 1 8 |g volume:171  |g year:2011  |g number:1  |g month:11  |g pages:87-93  |g extent:7  |a Computer-based liver volumetry in the liver perfusion simulator 
856 4 0 |u https://doi.org/10.1016/j.jss.2010.02.038  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0022480410001629  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220914 
993 |a Article 
994 |a 2011 
998 |g 1026855721  |a Schmied, Bruno  |m 1026855721:Schmied, Bruno  |d 50000  |e 50000PS1026855721  |k 0/50000/  |p 8  |y j 
998 |g 10927279X  |a Meinzer, Hans-Peter  |m 10927279X:Meinzer, Hans-Peter  |d 50000  |e 50000PM10927279X  |k 0/50000/  |p 7 
998 |g 123910846  |a Radeleff, Boris  |m 123910846:Radeleff, Boris  |d 910000  |d 911400  |e 910000PR123910846  |e 911400PR123910846  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1065677154  |a Fonouni, Hamidreza  |m 1065677154:Fonouni, Hamidreza  |d 910000  |d 910200  |e 910000PF1065677154  |e 910200PF1065677154  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 137664583  |a Mehrabi, Arianeb  |m 137664583:Mehrabi, Arianeb  |d 910000  |d 910200  |e 910000PM137664583  |e 910200PM137664583  |k 0/910000/  |k 1/910000/910200/  |p 4 
998 |g 137850204  |a Schöbinger, Maximilian  |m 137850204:Schöbinger, Maximilian  |d 50000  |e 50000PS137850204  |k 0/50000/  |p 3 
998 |g 1047089793  |a Pianka, Frank  |m 1047089793:Pianka, Frank  |d 50000  |e 50000PP1047089793  |k 0/50000/  |p 2 
998 |g 1021104795  |a Müller, Sascha A.  |m 1021104795:Müller, Sascha A.  |d 50000  |e 50000PM1021104795  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1816642754  |e 418813366X 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","family":"Müller","display":"Müller, Sascha A.","given":"Sascha A."},{"display":"Pianka, Frank","given":"Frank","family":"Pianka","role":"aut"},{"role":"aut","family":"Schöbinger","display":"Schöbinger, Maximilian","given":"Maximilian"},{"family":"Mehrabi","display":"Mehrabi, Arianeb","given":"Arianeb","role":"aut"},{"role":"aut","given":"Hamidreza","display":"Fonouni, Hamidreza","family":"Fonouni"},{"role":"aut","given":"Boris","display":"Radeleff, Boris","family":"Radeleff"},{"display":"Meinzer, Hans-Peter","given":"Hans-Peter","family":"Meinzer","role":"aut"},{"given":"Bruno","display":"Schmied, Bruno","family":"Schmied","role":"aut"}],"recId":"1816642754","name":{"displayForm":["Sascha Arian Müller, M.D., Frank Pianka, M.D., Max Schöbinger, Arianeb Mehrabi, M.D., Hamid Fonouni, M.D., Boris Radeleff, M.D., Hans-Peter Meinzer, Prof., and Bruno M. Schmied, M.D."]},"origin":[{"dateIssuedDisp":"2011","dateIssuedKey":"2011"}],"language":["eng"],"title":[{"title_sort":"Computer-based liver volumetry in the liver perfusion simulator","title":"Computer-based liver volumetry in the liver perfusion simulator"}],"physDesc":[{"extent":"7 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1816642754"],"doi":["10.1016/j.jss.2010.02.038"]},"relHost":[{"pubHistory":["1.1961 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"267836821","disp":"Computer-based liver volumetry in the liver perfusion simulatorJournal of surgical research","language":["eng"],"titleAlt":[{"title":"JSR"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["1470806-1"],"issn":["1095-8673"],"eki":["267836821"]},"part":{"issue":"1","extent":"7","text":"171(2011), 1 vom: Nov., Seite 87-93","volume":"171","pages":"87-93","year":"2011"},"note":["Gesehen am 30.01.2020"],"origin":[{"dateIssuedKey":"1961","publisherPlace":"Orlando, Fla.","publisher":"Academic Press","dateIssuedDisp":"1961-"}],"corporate":[{"role":"isb","display":"Association for Academic Surgery"},{"role":"isb","display":"Association of Veterans Administration Surgeons"}],"title":[{"title":"Journal of surgical research","subtitle":"JSR ; clinical and laboratory investigation ; official publication of the Association for Academic Surgery ; official publication of the Association of Veterans Administration Surgeons","title_sort":"Journal of surgical research"}]}],"note":["First published online: 20 March 2010","Gesehen am 14.09.2022"]} 
SRT |a MUELLERSASCOMPUTERBA2011