Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts

Objectives - The study aimed to test whether reliability and inter-observer variability of preoperative measurements for thoracic endovascular aortic repair (TEVAR) among non-experts are improved by semiautomatic centerline analysis compared with manual assessment. - Methods - Preoperative computed...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rengier, Fabian (VerfasserIn) , Weber, Tim (VerfasserIn) , Partovi, S. (VerfasserIn) , Müller-Eschner, M. (VerfasserIn) , Böckler, Dittmar (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Tengg-Kobligk, Hendrik von (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 13 May 2011
In: European journal of vascular and endovascular surgery
Year: 2011, Jahrgang: 42, Heft: 3, Pages: 324-331
ISSN:1532-2165
DOI:10.1016/j.ejvs.2011.04.019
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejvs.2011.04.019
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1078588411002279
Volltext
Verfasserangaben:F. Rengier, T.F. Weber, S. Partovi, M. Müller-Eschner, D. Böckler, H.-U. Kauczor, H. von Tengg-Kobligk

MARC

LEADER 00000caa a2200000 c 4500
001 1816707279
003 DE-627
005 20240417193531.0
007 cr uuu---uuuuu
008 220915s2011 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejvs.2011.04.019  |2 doi 
035 |a (DE-627)1816707279 
035 |a (DE-599)KXP1816707279 
035 |a (OCoLC)1389788927 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rengier, Fabian  |d 1986-  |e VerfasserIn  |0 (DE-588)139065865  |0 (DE-627)608103284  |0 (DE-576)309935873  |4 aut 
245 1 0 |a Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts  |c F. Rengier, T.F. Weber, S. Partovi, M. Müller-Eschner, D. Böckler, H.-U. Kauczor, H. von Tengg-Kobligk 
264 1 |c 13 May 2011 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.09.2022 
520 |a Objectives - The study aimed to test whether reliability and inter-observer variability of preoperative measurements for thoracic endovascular aortic repair (TEVAR) among non-experts are improved by semiautomatic centerline analysis compared with manual assessment. - Methods - Preoperative computed tomography (CT) angiographies of 30 patients with thoracic aortic disease (mean age 66.8 ± 11.6 years, 23 men) were retrospectively analysed in randomised order by one blinded vascular expert (reference standard) and three blinded non-expert readers. Aortic diameters were measured at four positions relevant to TEVAR using three measurement techniques (manual axial slices, manual multiplanar reformations (MPRs) and semiautomatic centerline analysis). Length measurements were performed using centerline analysis. Reliability was calculated as absolute measurement deviation (AMD) from reference standard and inter-observer variability as coefficient of variance (CV) among non-expert readers. - Results - For axial, MPR and centerline techniques, mean AMD was 7.3 ± 7.7%, 6.7 ± 4.5% and 4.7 ± 4.8% and mean CV was 5.2 ± 4.2%, 5.8 ± 4.8% and 3.9 ± 5.4%. Both AMD and CV were significantly lower for centerline analysis compared with axial technique (p = 0.001/0.042) and MPR (p = 0.009/0.003). AMD and CV for length measurements by centerline analysis were 3.2 ± 2.8% and 2.6 ± 2.4%, respectively. Centerline analysis was significantly faster than MPR (p < 0.001). - Conclusions - Semiautomatic centerline analysis provides the most reliable and least variable diameter and length measurements among non-experts in candidates for TEVAR. 
650 4 |a Computed tomography 
650 4 |a Computer-assisted image analysis 
650 4 |a Endovascular 
650 4 |a Thoracic aorta 
650 4 |a Three-dimensional imaging 
700 1 |a Weber, Tim  |d 1977-  |e VerfasserIn  |0 (DE-588)133392694  |0 (DE-627)544045017  |0 (DE-576)299816613  |4 aut 
700 1 |a Partovi, S.  |e VerfasserIn  |4 aut 
700 1 |a Müller-Eschner, M.  |e VerfasserIn  |4 aut 
700 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Tengg-Kobligk, Hendrik von  |d 1972-  |e VerfasserIn  |0 (DE-588)129455733  |0 (DE-627)397663188  |0 (DE-576)297668501  |4 aut 
773 0 8 |i Enthalten in  |t European journal of vascular and endovascular surgery  |d New York, NY : Elsevier, 1995  |g 42(2011), 3, Seite 324-331  |h Online-Ressource  |w (DE-627)320444872  |w (DE-600)2005354-X  |w (DE-576)104558539  |x 1532-2165  |7 nnas  |a Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts 
773 1 8 |g volume:42  |g year:2011  |g number:3  |g pages:324-331  |g extent:8  |a Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts 
856 4 0 |u https://doi.org/10.1016/j.ejvs.2011.04.019  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S1078588411002279  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220915 
993 |a Article 
994 |a 2011 
998 |g 129455733  |a Tengg-Kobligk, Hendrik von  |m 129455733:Tengg-Kobligk, Hendrik von  |d 50000  |e 50000PT129455733  |k 0/50000/  |p 7  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 50000  |e 50000PB1032367881  |k 0/50000/  |p 5 
998 |g 133392694  |a Weber, Tim  |m 133392694:Weber, Tim  |d 910000  |d 911400  |e 910000PW133392694  |e 911400PW133392694  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 139065865  |a Rengier, Fabian  |m 139065865:Rengier, Fabian  |d 50000  |e 50000PR139065865  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1816707279  |e 4188815841 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["F. Rengier, T.F. Weber, S. Partovi, M. Müller-Eschner, D. Böckler, H.-U. Kauczor, H. von Tengg-Kobligk"]},"id":{"doi":["10.1016/j.ejvs.2011.04.019"],"eki":["1816707279"]},"origin":[{"dateIssuedDisp":"13 May 2011","dateIssuedKey":"2011"}],"relHost":[{"origin":[{"dateIssuedDisp":"1995-","dateIssuedKey":"1995","publisherPlace":"New York, NY ; [Erscheinungsort nicht ermittelbar] ; London","publisher":"Elsevier ; Saunders ; Harcourt Publ."}],"title":[{"title_sort":"European journal of vascular and endovascular surgery","title":"European journal of vascular and endovascular surgery"}],"note":["Gesehen am 05.02.20"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"recId":"320444872","physDesc":[{"extent":"Online-Ressource"}],"disp":"Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-expertsEuropean journal of vascular and endovascular surgery","pubHistory":["9.1995 -"],"titleAlt":[{"title":"EJVES"}],"part":{"pages":"324-331","text":"42(2011), 3, Seite 324-331","extent":"8","issue":"3","year":"2011","volume":"42"},"id":{"eki":["320444872"],"issn":["1532-2165"],"zdb":["2005354-X"]}}],"person":[{"display":"Rengier, Fabian","given":"Fabian","role":"aut","family":"Rengier"},{"family":"Weber","role":"aut","given":"Tim","display":"Weber, Tim"},{"display":"Partovi, S.","role":"aut","given":"S.","family":"Partovi"},{"family":"Müller-Eschner","role":"aut","given":"M.","display":"Müller-Eschner, M."},{"display":"Böckler, Dittmar","role":"aut","given":"Dittmar","family":"Böckler"},{"display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","role":"aut","family":"Kauczor"},{"given":"Hendrik von","role":"aut","family":"Tengg-Kobligk","display":"Tengg-Kobligk, Hendrik von"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 15.09.2022"],"title":[{"title_sort":"Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts","title":"Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts"}],"physDesc":[{"extent":"8 S."}],"recId":"1816707279"} 
SRT |a RENGIERFABRELIABILIT1320