Assessment of early toxicity and response in patients treated with proton and carbon ion therapy at the Heidelberg Ion Therapy Center using the raster scanning technique

Puropose - To asses early toxicity and response in 118 patients treated with scanned ion beams to validate the safety of intensity-controlled raster scanning at the Heidelberg Ion Therapy Center. - Patients and Methods - Between November 2009 and June 2010, we treated 118 patients with proton and ca...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rieken, Stefan (VerfasserIn) , Habermehl, Daniel (VerfasserIn) , Nikoghosyan, Anna (VerfasserIn) , Jensen, Alexandra (VerfasserIn) , Haberer, Thomas (VerfasserIn) , Jäkel, Oliver (VerfasserIn) , Münter, Marc (VerfasserIn) , Welzel, Thomas (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Combs, Stephanie (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 6 February 2011
In: International journal of radiation oncology, biology, physics
Year: 2011, Jahrgang: 81, Heft: 5, Pages: e793-e801
ISSN:1879-355X
DOI:10.1016/j.ijrobp.2010.12.018
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ijrobp.2010.12.018
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S036030161003720X
Volltext
Verfasserangaben:Stefan Rieken, Daniel Habermehl, Anna Nikoghosyan, Alexandra Jensen, Thomas Haberer, Oliver Jäkel, Marc W. Münter, Thomas Welzel, Jürgen Debus, and Stephanie E. Combs

MARC

LEADER 00000caa a2200000 c 4500
001 1816767182
003 DE-627
005 20250827110943.0
007 cr uuu---uuuuu
008 220916s2011 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ijrobp.2010.12.018  |2 doi 
035 |a (DE-627)1816767182 
035 |a (DE-599)KXP1816767182 
035 |a (OCoLC)1389789531 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rieken, Stefan  |d 1979-  |e VerfasserIn  |0 (DE-588)135553385  |0 (DE-627)567062570  |0 (DE-576)278641725  |4 aut 
245 1 0 |a Assessment of early toxicity and response in patients treated with proton and carbon ion therapy at the Heidelberg Ion Therapy Center using the raster scanning technique  |c Stefan Rieken, Daniel Habermehl, Anna Nikoghosyan, Alexandra Jensen, Thomas Haberer, Oliver Jäkel, Marc W. Münter, Thomas Welzel, Jürgen Debus, and Stephanie E. Combs 
264 1 |c 6 February 2011 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.09.2022 
520 |a Puropose - To asses early toxicity and response in 118 patients treated with scanned ion beams to validate the safety of intensity-controlled raster scanning at the Heidelberg Ion Therapy Center. - Patients and Methods - Between November 2009 and June 2010, we treated 118 patients with proton and carbon ion radiotherapy (RT) using active beam delivery. The main indications included skull base chordomas and chondrosarcomas, salivary gland tumors, and gliomas. We evaluated early toxicity within 6 weeks after RT and the initial clinical and radiologic response for quality assurance in our new facility. - Results - In all 118 patients, few side effects were observed, in particular, no high numbers of severe acute toxicity were found. In general, the patients treated with particle therapy alone showed only a few single side effects, mainly Radiation Therapy Oncology Group/Common Terminology Criteria grade 1. The most frequent side effects and cumulative incidence of single side effects were observed in the head-and-neck patients treated with particle therapy as a boost and photon intensity-modulated RT. The toxicities included common radiation-attributed reactions known from photon RT, including mucositis, dysphagia, and skin erythema. The most predominant imaging responses were observed in patients with high-grade gliomas and those with salivary gland tumors. For skull base tumors, imaging showed a stable tumor outline in most patients. Thirteen patients showed improvement of pre-existing clinical symptoms. - Conclusions - Side effects related to particle treatment were rare, and the overall tolerability of the treatment was shown. The initial response was promising. The data have confirmed the safe delivery of carbon ions and protons at the newly opened Heidelberg facility. 
650 4 |a Beam scanning 
650 4 |a Carbon ion radiotherapy 
650 4 |a Proton therapy 
650 4 |a Raster scanning 
650 4 |a Toxicity 
700 1 |a Habermehl, Daniel  |d 1979-  |e VerfasserIn  |0 (DE-588)13804130X  |0 (DE-627)598882472  |0 (DE-576)305815415  |4 aut 
700 1 |a Nikoghosyan, Anna  |d 1974-  |e VerfasserIn  |0 (DE-588)129613355  |0 (DE-627)474758192  |0 (DE-576)297749196  |4 aut 
700 1 |a Jensen, Alexandra  |d 1976-  |e VerfasserIn  |0 (DE-588)136129552  |0 (DE-627)577179020  |0 (DE-576)284704687  |4 aut 
700 1 |a Haberer, Thomas  |d 1960-  |e VerfasserIn  |0 (DE-588)123579198  |0 (DE-627)706353714  |0 (DE-576)214902188  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Münter, Marc  |d 1972-  |e VerfasserIn  |0 (DE-588)121295591  |0 (DE-627)705363104  |0 (DE-576)292633645  |4 aut 
700 1 |a Welzel, Thomas  |d 1967-  |e VerfasserIn  |0 (DE-588)1056889012  |0 (DE-627)794179746  |0 (DE-576)412868164  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Combs, Stephanie  |d 1976-  |e VerfasserIn  |0 (DE-588)124782515  |0 (DE-627)366051245  |0 (DE-576)294499741  |4 aut 
773 0 8 |i Enthalten in  |t International journal of radiation oncology, biology, physics  |d Amsterdam [u.a.] : Elsevier Science, 1975  |g 81(2011), 5, Seite e793-e801  |h Online-Ressource  |w (DE-627)306659662  |w (DE-600)1500486-7  |w (DE-576)081986319  |x 1879-355X  |7 nnas  |a Assessment of early toxicity and response in patients treated with proton and carbon ion therapy at the Heidelberg Ion Therapy Center using the raster scanning technique 
773 1 8 |g volume:81  |g year:2011  |g number:5  |g pages:e793-e801  |g extent:9  |a Assessment of early toxicity and response in patients treated with proton and carbon ion therapy at the Heidelberg Ion Therapy Center using the raster scanning technique 
856 4 0 |u https://doi.org/10.1016/j.ijrobp.2010.12.018  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S036030161003720X  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220916 
993 |a Article 
994 |a 2011 
998 |g 124782515  |a Combs, Stephanie  |m 124782515:Combs, Stephanie  |d 910000  |d 911400  |e 910000PC124782515  |e 911400PC124782515  |k 0/910000/  |k 1/910000/911400/  |p 10  |y j 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 9 
998 |g 1056889012  |a Welzel, Thomas  |m 1056889012:Welzel, Thomas  |d 910000  |d 911400  |e 910000PW1056889012  |e 911400PW1056889012  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 121295591  |a Münter, Marc  |m 121295591:Münter, Marc  |d 50000  |e 50000PM121295591  |k 0/50000/  |p 7 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 6 
998 |g 123579198  |a Haberer, Thomas  |m 123579198:Haberer, Thomas  |d 910000  |d 950000  |d 950400  |e 910000PH123579198  |e 950000PH123579198  |e 950400PH123579198  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 5 
998 |g 136129552  |a Jensen, Alexandra  |m 136129552:Jensen, Alexandra  |p 4 
998 |g 129613355  |a Nikoghosyan, Anna  |m 129613355:Nikoghosyan, Anna  |d 910000  |d 911400  |e 910000PN129613355  |e 911400PN129613355  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 13804130X  |a Habermehl, Daniel  |m 13804130X:Habermehl, Daniel  |d 910000  |d 911400  |e 910000PH13804130X  |e 911400PH13804130X  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 135553385  |a Rieken, Stefan  |m 135553385:Rieken, Stefan  |d 910000  |d 911400  |e 910000PR135553385  |e 911400PR135553385  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1816767182  |e 4189273872 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Stefan","display":"Rieken, Stefan","role":"aut","family":"Rieken"},{"display":"Habermehl, Daniel","given":"Daniel","role":"aut","family":"Habermehl"},{"family":"Nikoghosyan","role":"aut","display":"Nikoghosyan, Anna","given":"Anna"},{"role":"aut","given":"Alexandra","display":"Jensen, Alexandra","family":"Jensen"},{"family":"Haberer","display":"Haberer, Thomas","given":"Thomas","role":"aut"},{"family":"Jäkel","role":"aut","display":"Jäkel, Oliver","given":"Oliver"},{"family":"Münter","role":"aut","given":"Marc","display":"Münter, Marc"},{"family":"Welzel","role":"aut","given":"Thomas","display":"Welzel, Thomas"},{"role":"aut","display":"Debus, Jürgen","given":"Jürgen","family":"Debus"},{"role":"aut","display":"Combs, Stephanie","given":"Stephanie","family":"Combs"}],"title":[{"title":"Assessment of early toxicity and response in patients treated with proton and carbon ion therapy at the Heidelberg Ion Therapy Center using the raster scanning technique","title_sort":"Assessment of early toxicity and response in patients treated with proton and carbon ion therapy at the Heidelberg Ion Therapy Center using the raster scanning technique"}],"physDesc":[{"extent":"9 S."}],"id":{"doi":["10.1016/j.ijrobp.2010.12.018"],"eki":["1816767182"]},"name":{"displayForm":["Stefan Rieken, Daniel Habermehl, Anna Nikoghosyan, Alexandra Jensen, Thomas Haberer, Oliver Jäkel, Marc W. Münter, Thomas Welzel, Jürgen Debus, and Stephanie E. Combs"]},"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1816767182","relHost":[{"disp":"Assessment of early toxicity and response in patients treated with proton and carbon ion therapy at the Heidelberg Ion Therapy Center using the raster scanning techniqueInternational journal of radiation oncology, biology, physics","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"International journal of radiation oncology, biology, physics","subtitle":"the official journal of the American Society for Therapeutic Radiology and Oncology","title":"International journal of radiation oncology, biology, physics"}],"part":{"pages":"e793-e801","year":"2011","text":"81(2011), 5, Seite e793-e801","extent":"9","volume":"81","issue":"5"},"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"306659662","pubHistory":["1.1975/76 -"],"origin":[{"dateIssuedDisp":"1975-","publisher":"Elsevier Science","dateIssuedKey":"1975","publisherPlace":"Amsterdam [u.a.]"}],"note":["Gesehen am 15.01.20","Ungezählte Beil.: Supplement"],"id":{"issn":["1879-355X"],"zdb":["1500486-7"],"eki":["306659662"]},"language":["eng"]}],"origin":[{"dateIssuedDisp":"6 February 2011","dateIssuedKey":"2011"}],"note":["Gesehen am 16.09.2022"]} 
SRT |a RIEKENSTEFASSESSMENT6201