Pullout strength of all-suture and metallic anchors in repair of lateral collateral ligament injuries of the elbow

Purpose - To compare the biomechanical properties of metallic anchor (MA) and all-suture anchor (ASA) constructs in the anatomic reattachment of the lateral ulnar collateral ligament complex to its humeral insertion. - Methods - Twenty paired male human cadaveric elbows with a mean age of 46.3 years...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Midtgaard, Kaare S. (VerfasserIn) , Nolte, Philip-Christian (VerfasserIn) , Miles, Jon W. (VerfasserIn) , Tanghe, Kira K. (VerfasserIn) , Douglass, Brenton W. (VerfasserIn) , Peebles, Liam A. (VerfasserIn) , Provencher, Matthew T. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 12 June 2021
In: Arthroscopy
Year: 2021, Jahrgang: 37, Heft: 9, Pages: 2800-2806
ISSN:1526-3231
DOI:10.1016/j.arthro.2021.05.060
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.arthro.2021.05.060
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0749806321005739
Volltext
Verfasserangaben:Kaare S. Midtgaard, MD, Philip-C. Nolte, MA, MD, Jon W. Miles, MSc, Kira K. Tanghe, BS, Brenton W. Douglass, MD, Liam A. Peebles, BA, and Matthew T. Provencher, MD, MBA, CAPT, MC, USNR (Ret)

MARC

LEADER 00000caa a2200000 c 4500
001 1816768162
003 DE-627
005 20240417193540.0
007 cr uuu---uuuuu
008 220916s2021 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.arthro.2021.05.060  |2 doi 
035 |a (DE-627)1816768162 
035 |a (DE-599)KXP1816768162 
035 |a (OCoLC)1361714322 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Midtgaard, Kaare S.  |e VerfasserIn  |0 (DE-588)1268216364  |0 (DE-627)1816769061  |4 aut 
245 1 0 |a Pullout strength of all-suture and metallic anchors in repair of lateral collateral ligament injuries of the elbow  |c Kaare S. Midtgaard, MD, Philip-C. Nolte, MA, MD, Jon W. Miles, MSc, Kira K. Tanghe, BS, Brenton W. Douglass, MD, Liam A. Peebles, BA, and Matthew T. Provencher, MD, MBA, CAPT, MC, USNR (Ret) 
264 1 |c 12 June 2021 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.09.2022 
520 |a Purpose - To compare the biomechanical properties of metallic anchor (MA) and all-suture anchor (ASA) constructs in the anatomic reattachment of the lateral ulnar collateral ligament complex to its humeral insertion. - Methods - Twenty paired male human cadaveric elbows with a mean age of 46.3 years (range: 33-58 years) were used in this study. Each pair was randomly allocated across 2 groups of either MA or ASA. A single 3.5-mm MA or 2.6-mm ASA was then inserted flush into the lateral epicondyle. A dynamic tensile testing machine was used to perform cyclic loading followed by a load to failure test. During the cyclic loading phase, the anchors were sinusoidally tensioned from 10 N to 100 N for 1,000 cycles at a frequency of 0.5 Hz. In the load to failure test, the anchors were pulled at a rate of 3 mm/s. Load at 1-mm and 2-mm displacement, as well as load to ultimate failure were assessed. Clinical failure was defined as displacement of more than 2 mm. Normality of data was assessed with the Shapiro-Wilk test. Continuous data are presented as medians and compared with the Mann-Whitney U test and categorical data was compared with the χ2 test or Fisher exact test. - Results - Displacement was significantly greater for the ASA group during cyclic loading starting from the tenth cycle (P < .05). Displacement of more than 5 mm within the first 100 cycles was observed in 2 anchors in the ASA group. No difference was observed in loads required to displace 1 mm (MA: 146 N [6-169] vs ASA: 144 N [2-153]; P = .53) and 2 mm (MA: 171 N [13-202] vs ASA: 161 N [9-191]; P = .97), but there was a statistically significant difference between ultimate loads in favor of ASA in the load to failure test (MA: 297 N [84-343] vs 463 N [176-620]; P < .01). - Conclusions - In the cyclic test, no difference in clinical failure defined as pull-out of more than 2 mm was observed between 3.5 mm MAs and 2.6 mm ASAs. In the ultimate load to failure analysis, no difference was observed between groups in force causing 1 and 2 mm of displacement, but there was a significant difference in favor of ASA in the pull to ultimate failure test. - Clinical Relevance - Potential benefits of all-suture anchors include preservation of bone stock, reduced radiographic artifacts, and easier revisions. Although their use has been investigated thoroughly in the shoulder, there remains a paucity of literature regarding displacement and pull-out strength in the elbow. 
700 1 |a Nolte, Philip-Christian  |d 1987-  |e VerfasserIn  |0 (DE-588)105698712X  |0 (DE-627)794361757  |0 (DE-576)41297102X  |4 aut 
700 1 |a Miles, Jon W.  |e VerfasserIn  |4 aut 
700 1 |a Tanghe, Kira K.  |e VerfasserIn  |4 aut 
700 1 |a Douglass, Brenton W.  |e VerfasserIn  |4 aut 
700 1 |a Peebles, Liam A.  |e VerfasserIn  |4 aut 
700 1 |a Provencher, Matthew T.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Arthroscopy  |d Philadelphia, Pa. [u.a.] : Elsevier, 1985  |g 37(2021), 9 vom: Sept., Seite 2800-2806  |h Online-Ressource  |w (DE-627)302467289  |w (DE-600)1491233-8  |w (DE-576)091014743  |x 1526-3231  |7 nnas  |a Pullout strength of all-suture and metallic anchors in repair of lateral collateral ligament injuries of the elbow 
773 1 8 |g volume:37  |g year:2021  |g number:9  |g month:09  |g pages:2800-2806  |g extent:7  |a Pullout strength of all-suture and metallic anchors in repair of lateral collateral ligament injuries of the elbow 
856 4 0 |u https://doi.org/10.1016/j.arthro.2021.05.060  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0749806321005739  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220916 
993 |a Article 
994 |a 2021 
998 |g 105698712X  |a Nolte, Philip-Christian  |m 105698712X:Nolte, Philip-Christian  |d 50000  |e 50000PN105698712X  |k 0/50000/  |p 2 
999 |a KXP-PPN1816768162  |e 418927609X 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"recId":"302467289","language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Pullout strength of all-suture and metallic anchors in repair of lateral collateral ligament injuries of the elbowArthroscopy","note":["Gesehen am 13.03.25"],"part":{"volume":"37","text":"37(2021), 9 vom: Sept., Seite 2800-2806","extent":"7","year":"2021","pages":"2800-2806","issue":"9"},"pubHistory":["1.1985 -"],"title":[{"title":"Arthroscopy","subtitle":"the journal of arthroscopic & related surgery","title_sort":"Arthroscopy"}],"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["Arthroscopy Association of North America"]},"id":{"zdb":["1491233-8"],"eki":["302467289"],"issn":["1526-3231"]},"origin":[{"publisherPlace":"Philadelphia, Pa. [u.a.] ; Philadelphia, Pa.","dateIssuedDisp":"1985-","dateIssuedKey":"1985","publisher":"Elsevier ; Saunders"}]}],"physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Kaare S. Midtgaard, MD, Philip-C. Nolte, MA, MD, Jon W. Miles, MSc, Kira K. Tanghe, BS, Brenton W. Douglass, MD, Liam A. Peebles, BA, and Matthew T. Provencher, MD, MBA, CAPT, MC, USNR (Ret)"]},"id":{"eki":["1816768162"],"doi":["10.1016/j.arthro.2021.05.060"]},"origin":[{"dateIssuedDisp":"12 June 2021","dateIssuedKey":"2021"}],"recId":"1816768162","language":["eng"],"note":["Gesehen am 16.09.2022"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"display":"Midtgaard, Kaare S.","roleDisplay":"VerfasserIn","role":"aut","family":"Midtgaard","given":"Kaare S."},{"family":"Nolte","given":"Philip-Christian","roleDisplay":"VerfasserIn","display":"Nolte, Philip-Christian","role":"aut"},{"given":"Jon W.","family":"Miles","role":"aut","roleDisplay":"VerfasserIn","display":"Miles, Jon W."},{"given":"Kira K.","family":"Tanghe","role":"aut","roleDisplay":"VerfasserIn","display":"Tanghe, Kira K."},{"given":"Brenton W.","family":"Douglass","role":"aut","roleDisplay":"VerfasserIn","display":"Douglass, Brenton W."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Peebles, Liam A.","given":"Liam A.","family":"Peebles"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Provencher, Matthew T.","given":"Matthew T.","family":"Provencher"}],"title":[{"title":"Pullout strength of all-suture and metallic anchors in repair of lateral collateral ligament injuries of the elbow","title_sort":"Pullout strength of all-suture and metallic anchors in repair of lateral collateral ligament injuries of the elbow"}]} 
SRT |a MIDTGAARDKPULLOUTSTR1220