Shear stress and force required for tether formation of neonatal and adult erythrocytes

Red blood cells (RBC) of neonates have a shorter survival time and they are more susceptible to mechanical alterations than RBC of adults. Irreversible alteration of the membrane of RBC of preterm neonates, term neonates and adults due to tether formation was studied by means of a micropipette techn...

Full description

Saved in:
Bibliographic Details
Main Authors: Ruef, Peter (Author) , Gehm, J. (Author) , Gehm, L. (Author) , Pöschl, Johannes (Author)
Format: Article (Journal)
Language:English
Published: 2011
In: Clinical hemorheology and microcirculation
Year: 2011, Volume: 48, Issue: 1/3, Pages: 119-128
ISSN:1875-8622
DOI:10.3233/CH-2011-1390
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3233/CH-2011-1390
Verlag, lizenzpflichtig, Volltext: https://content.iospress.com/articles/clinical-hemorheology-and-microcirculation/ch1390
Get full text
Author Notes:P. Ruef, J. Gehm, L. Gehm and J. Pöschl

MARC

LEADER 00000caa a2200000 c 4500
001 1817209744
003 DE-627
005 20230912094642.0
007 cr uuu---uuuuu
008 220921s2011 xx |||||o 00| ||eng c
024 7 |a 10.3233/CH-2011-1390  |2 doi 
035 |a (DE-627)1817209744 
035 |a (DE-599)KXP1817209744 
035 |a (OCoLC)1389786122 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ruef, Peter  |e VerfasserIn  |0 (DE-588)1076745385  |0 (DE-627)835283321  |0 (DE-576)173087639  |4 aut 
245 1 0 |a Shear stress and force required for tether formation of neonatal and adult erythrocytes  |c P. Ruef, J. Gehm, L. Gehm and J. Pöschl 
264 1 |c 2011 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.09.2022 
520 |a Red blood cells (RBC) of neonates have a shorter survival time and they are more susceptible to mechanical alterations than RBC of adults. Irreversible alteration of the membrane of RBC of preterm neonates, term neonates and adults due to tether formation was studied by means of a micropipette technique. Shear stress and forces were applied with this technique in an axisymmetric configuration and were calculated with an approximation method. The applied shear stress and forces that induced tether formation were lowest for RBC of preterm neonates (1.5 Pa, 1.8 pN), in between for RBC of neonates (1.7 Pa, 2.1 pN) and highest for RBC in adults (1.9 Pa, 2.6 pN). Decreased mechanical stability of the membrane of neonatal RBC may in part cause the shorter life span, the greater tendency to endocytosis and the higher amount of irregularly shaped cells of neonatal RBC compared to RBC in adults. 
700 1 |a Gehm, J.  |e VerfasserIn  |4 aut 
700 1 |a Gehm, L.  |e VerfasserIn  |4 aut 
700 1 |a Pöschl, Johannes  |e VerfasserIn  |0 (DE-588)1021936847  |0 (DE-627)715839977  |0 (DE-576)36384757X  |4 aut 
773 0 8 |i Enthalten in  |t Clinical hemorheology and microcirculation  |d London : Sage, 1997  |g 48(2011), 1/3, Seite 119-128  |h Online-Ressource  |w (DE-627)323607861  |w (DE-600)2026405-7  |w (DE-576)273879375  |x 1875-8622  |7 nnas  |a Shear stress and force required for tether formation of neonatal and adult erythrocytes 
773 1 8 |g volume:48  |g year:2011  |g number:1/3  |g pages:119-128  |g extent:10  |a Shear stress and force required for tether formation of neonatal and adult erythrocytes 
856 4 0 |u https://doi.org/10.3233/CH-2011-1390  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://content.iospress.com/articles/clinical-hemorheology-and-microcirculation/ch1390  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220921 
993 |a Article 
994 |a 2011 
998 |g 1021936847  |a Pöschl, Johannes  |m 1021936847:Pöschl, Johannes  |d 50000  |e 50000PP1021936847  |k 0/50000/  |p 4  |y j 
998 |g 1076745385  |a Ruef, Peter  |m 1076745385:Ruef, Peter  |d 50000  |e 50000PR1076745385  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1817209744  |e 419047293X 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["P. Ruef, J. Gehm, L. Gehm and J. Pöschl"]},"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011"}],"id":{"eki":["1817209744"],"doi":["10.3233/CH-2011-1390"]},"physDesc":[{"extent":"10 S."}],"relHost":[{"recId":"323607861","language":["eng"],"note":["Gesehen am 05.03.2025"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Shear stress and force required for tether formation of neonatal and adult erythrocytesClinical hemorheology and microcirculation","part":{"extent":"10","volume":"48","text":"48(2011), 1/3, Seite 119-128","issue":"1/3","pages":"119-128","year":"2011"},"pubHistory":["17.1997 -"],"title":[{"title_sort":"Clinical hemorheology and microcirculation","title":"Clinical hemorheology and microcirculation","subtitle":"blood flow and vessels"}],"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["published in association with IOS Press"]},"id":{"issn":["1875-8622"],"zdb":["2026405-7"],"eki":["323607861"]},"origin":[{"publisherPlace":"London ; Amsterdam [u.a.]","publisher":"Sage ; IOS Press","dateIssuedKey":"2025","dateIssuedDisp":"2025-"}]}],"person":[{"role":"aut","display":"Ruef, Peter","roleDisplay":"VerfasserIn","given":"Peter","family":"Ruef"},{"family":"Gehm","given":"J.","roleDisplay":"VerfasserIn","display":"Gehm, J.","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Gehm, L.","given":"L.","family":"Gehm"},{"display":"Pöschl, Johannes","roleDisplay":"VerfasserIn","role":"aut","family":"Pöschl","given":"Johannes"}],"title":[{"title":"Shear stress and force required for tether formation of neonatal and adult erythrocytes","title_sort":"Shear stress and force required for tether formation of neonatal and adult erythrocytes"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 21.09.2022"],"language":["eng"],"recId":"1817209744"} 
SRT |a RUEFPETERGSHEARSTRES2011