A new method to analyze distortion product otoacoustic emissions (DPOAEs) in the high-frequency range up to 18 kHz using windowed periodograms

Distortion product otoacoustic emissions (DPOAEs) are widely used as an objective examination procedure to determine cochlear function. In a clinical routine setting, the amplitude of the DPOAE signal at 2f1-f2 is applied as an indicator for a potential hearing loss up to 8 kHz. Due to their poor si...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hecker, Dietmar J. (VerfasserIn) , Lohscheller, Joerg (VerfasserIn) , Bader, Carl-Albert (VerfasserIn) , Delb, Wolfgang (VerfasserIn) , Schick, Bernhard (VerfasserIn) , Dlugaiczyk, Julia (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [August 2011]
In: IEEE transactions on biomedical engineering
Year: 2011, Jahrgang: 58, Heft: 8, Pages: 2369-2377
ISSN:1558-2531
DOI:10.1109/TBME.2011.2157154
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1109/TBME.2011.2157154
Volltext
Verfasserangaben:Dietmar J. Hecker, Joerg Lohscheller, Carl-Albert Bader, Wolfgang Delb, Bernhard Schick, Julia Dlugaiczyk

MARC

LEADER 00000caa a22000002c 4500
001 1817699660
003 DE-627
005 20230710113606.0
007 cr uuu---uuuuu
008 220928s2011 xx |||||o 00| ||eng c
024 7 |a 10.1109/TBME.2011.2157154  |2 doi 
035 |a (DE-627)1817699660 
035 |a (DE-599)KXP1817699660 
035 |a (OCoLC)1389784144 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hecker, Dietmar J.  |d 1967-  |e VerfasserIn  |0 (DE-588)1269043048  |0 (DE-627)181770009X  |4 aut 
245 1 2 |a A new method to analyze distortion product otoacoustic emissions (DPOAEs) in the high-frequency range up to 18 kHz using windowed periodograms  |c Dietmar J. Hecker, Joerg Lohscheller, Carl-Albert Bader, Wolfgang Delb, Bernhard Schick, Julia Dlugaiczyk 
264 1 |c [August 2011] 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 28.09.2022 
520 |a Distortion product otoacoustic emissions (DPOAEs) are widely used as an objective examination procedure to determine cochlear function. In a clinical routine setting, the amplitude of the DPOAE signal at 2f1-f2 is applied as an indicator for a potential hearing loss up to 8 kHz. Due to their poor signal-to-noise ratio, meatal nodes from standing waves and calibration issues, high-frequency DPOAEs >; 8 kHz have hardly been addressed in experimental and clinical audiology so far. Here, we present a new method of measuring DPOAE signal levels based on optimal maximum likelihood estimation with windowed power spectral density estimation of stochastic signals and filtering theory. Analysis of simulated data showed that the proposed method effectively reduces the disturbing noise floor compared to conventional averaging techniques. Robust DPOAE signals were measured in 20 ears from ten normally hearing young adults (21-27 years) from 0.5 to 18 kHz . Repeated DPOAE recordings in one individual yielded a good to very good test-retest reliability of the proposed method. These observations are discussed in the context of DPOAE signal processing and possible clinical applications of high-frequency DPOAE measurements. 
650 4 |a Auditory system 
650 4 |a Ear 
650 4 |a High-frequency DPOAEs 
650 4 |a Maximum likelihood estimation 
650 4 |a Noise measurement 
650 4 |a otoacoustic emissions (OAEs) 
650 4 |a Probes 
650 4 |a pure-tone stimulation 
650 4 |a Signal to noise ratio 
650 4 |a signal-to-noise ratio 
700 1 |a Lohscheller, Joerg  |e VerfasserIn  |4 aut 
700 1 |a Bader, Carl-Albert  |e VerfasserIn  |4 aut 
700 1 |a Delb, Wolfgang  |d 1962-  |e VerfasserIn  |0 (DE-588)123886945  |0 (DE-627)085502766  |0 (DE-576)173696112  |4 aut 
700 1 |a Schick, Bernhard  |e VerfasserIn  |4 aut 
700 1 |a Dlugaiczyk, Julia  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |a Institute of Electrical and Electronics Engineers  |t IEEE transactions on biomedical engineering  |d New York, NY : IEEE, 1964  |g 58(2011), 8, Seite 2369-2377  |h Online-Ressource  |w (DE-627)320614050  |w (DE-600)2021742-0  |w (DE-576)094080682  |x 1558-2531  |7 nnas 
773 1 8 |g volume:58  |g year:2011  |g number:8  |g pages:2369-2377  |g extent:9  |a A new method to analyze distortion product otoacoustic emissions (DPOAEs) in the high-frequency range up to 18 kHz using windowed periodograms 
856 4 0 |u https://doi.org/10.1109/TBME.2011.2157154  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20220928 
993 |a Article 
994 |a 2011 
998 |g 123886945  |a Delb, Wolfgang  |m 123886945:Delb, Wolfgang  |d 60000  |d 62100  |e 60000PD123886945  |e 62100PD123886945  |k 0/60000/  |k 1/60000/62100/  |p 4 
999 |a KXP-PPN1817699660  |e 4192903512 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Dietmar J. Hecker, Joerg Lohscheller, Carl-Albert Bader, Wolfgang Delb, Bernhard Schick, Julia Dlugaiczyk"]},"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"[August 2011]"}],"id":{"doi":["10.1109/TBME.2011.2157154"],"eki":["1817699660"]},"physDesc":[{"extent":"9 S."}],"relHost":[{"part":{"year":"2011","issue":"8","pages":"2369-2377","volume":"58","text":"58(2011), 8, Seite 2369-2377","extent":"9"},"titleAlt":[{"title":"Transactions on biomedical engineering"}],"pubHistory":["11.1964 -"],"corporate":[{"roleDisplay":"VerfasserIn","display":"Institute of Electrical and Electronics Engineers","role":"aut"}],"language":["eng"],"recId":"320614050","disp":"Institute of Electrical and Electronics EngineersIEEE transactions on biomedical engineering","type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"subtitle":"a publication of the IEEE Engineering in Medicine and Biology Society","title":"IEEE transactions on biomedical engineering","title_sort":"IEEE transactions on biomedical engineering"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2021742-0"],"eki":["320614050"],"issn":["1558-2531"]},"origin":[{"publisherPlace":"New York, NY","dateIssuedDisp":"1964-","publisher":"IEEE","dateIssuedKey":"1964"}],"name":{"displayForm":["Institute of Electrical and Electronics Engineers"]}}],"person":[{"role":"aut","display":"Hecker, Dietmar J.","roleDisplay":"VerfasserIn","given":"Dietmar J.","family":"Hecker"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Lohscheller, Joerg","given":"Joerg","family":"Lohscheller"},{"display":"Bader, Carl-Albert","roleDisplay":"VerfasserIn","role":"aut","family":"Bader","given":"Carl-Albert"},{"roleDisplay":"VerfasserIn","display":"Delb, Wolfgang","role":"aut","family":"Delb","given":"Wolfgang"},{"family":"Schick","given":"Bernhard","display":"Schick, Bernhard","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Julia","family":"Dlugaiczyk","role":"aut","roleDisplay":"VerfasserIn","display":"Dlugaiczyk, Julia"}],"title":[{"title_sort":"new method to analyze distortion product otoacoustic emissions (DPOAEs) in the high-frequency range up to 18 kHz using windowed periodograms","title":"A new method to analyze distortion product otoacoustic emissions (DPOAEs) in the high-frequency range up to 18 kHz using windowed periodograms"}],"note":["Gesehen am 28.09.2022"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1817699660","language":["eng"]} 
SRT |a HECKERDIETNEWMETHODT2011