Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration: results of the AQuIRE bronchoscopy registry
Background - New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. - Methods - We prospectively enrolled pa...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
2011
|
| In: |
Chest
Year: 2011, Volume: 140, Issue: 6, Pages: 1557-1566 |
| ISSN: | 1931-3543 |
| DOI: | 10.1378/chest.10-2914 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1378/chest.10-2914 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0012369211606533 |
| Author Notes: | David E. Ost, MD, MPH; Armin Ernst, MD, FCCP; Xiudong Lei, PhD; David Feller-Kopman, MD, FCCP; George A. Eapen, MD, FCCP; Kevin L. Kovitz MD, FCCP; Felix J.F. Herth, MD, FCCP; and Michael Simoff, MD, FCCP; on behalf of the AQuIRE bronchoscopy registry |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1818901498 | ||
| 003 | DE-627 | ||
| 005 | 20230710110943.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 221013s2011 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1378/chest.10-2914 |2 doi | |
| 035 | |a (DE-627)1818901498 | ||
| 035 | |a (DE-599)KXP1818901498 | ||
| 035 | |a (OCoLC)1389767557 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Ost, David E. |e VerfasserIn |0 (DE-588)1270219448 |0 (DE-627)1818902869 |4 aut | |
| 245 | 1 | 0 | |a Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration |b results of the AQuIRE bronchoscopy registry |c David E. Ost, MD, MPH; Armin Ernst, MD, FCCP; Xiudong Lei, PhD; David Feller-Kopman, MD, FCCP; George A. Eapen, MD, FCCP; Kevin L. Kovitz MD, FCCP; Felix J.F. Herth, MD, FCCP; and Michael Simoff, MD, FCCP; on behalf of the AQuIRE bronchoscopy registry |
| 264 | 1 | |c 2011 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a First published online: 16 December 2015 | ||
| 500 | |a Gesehen am 13.10.2022 | ||
| 520 | |a Background - New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. - Methods - We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. - Results - We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). - Conclusions - To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further investigate other determinants of diagnostic yield. | ||
| 700 | 1 | |a Ernst, Armin |e VerfasserIn |4 aut | |
| 700 | 1 | |a Lei, Xiudong |e VerfasserIn |4 aut | |
| 700 | 1 | |a Feller-Kopman, David |e VerfasserIn |4 aut | |
| 700 | 1 | |a Eapen, George A. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Kovitz, Kevin L. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Herth, Felix |e VerfasserIn |0 (DE-588)1016095236 |0 (DE-627)705477568 |0 (DE-576)351509925 |4 aut | |
| 700 | 1 | |a Simoff, Michael |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Chest |d Amsterdam : Elsevier, 1935 |g 140(2011), 6 vom: Dez., Seite 1557-1566 |h Online-Ressource |w (DE-627)320460819 |w (DE-600)2007244-2 |w (DE-576)09089202X |x 1931-3543 |7 nnas |a Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration results of the AQuIRE bronchoscopy registry |
| 773 | 1 | 8 | |g volume:140 |g year:2011 |g number:6 |g month:12 |g pages:1557-1566 |g extent:10 |a Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration results of the AQuIRE bronchoscopy registry |
| 856 | 4 | 0 | |u https://doi.org/10.1378/chest.10-2914 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S0012369211606533 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20221013 | ||
| 993 | |a Article | ||
| 994 | |a 2011 | ||
| 998 | |g 1016095236 |a Herth, Felix |m 1016095236:Herth, Felix |d 910000 |d 950000 |d 950900 |d 50000 |e 910000PH1016095236 |e 950000PH1016095236 |e 950900PH1016095236 |e 50000PH1016095236 |k 0/910000/ |k 1/910000/950000/ |k 2/910000/950000/950900/ |k 0/50000/ |p 7 | ||
| 999 | |a KXP-PPN1818901498 |e 419707140X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"title":[{"title_sort":"Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration","subtitle":"results of the AQuIRE bronchoscopy registry","title":"Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1378/chest.10-2914"],"eki":["1818901498"]},"physDesc":[{"extent":"10 S."}],"relHost":[{"title":[{"title_sort":"Chest","title":"Chest","subtitle":"official publication of the American College of Chest Physicians ; for specialists in pulmonology, critical care, sleep medicine, thoracic surgery, cardiorespiratory interactions and related disciplines"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["320460819"],"issn":["1931-3543"],"zdb":["2007244-2"]},"origin":[{"publisher":"Elsevier ; American College of Chest Physicians","dateIssuedDisp":"1935-","dateIssuedKey":"1935","publisherPlace":"Amsterdam ; Northbrook, Ill. [u.a.]"}],"recId":"320460819","disp":"Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration results of the AQuIRE bronchoscopy registryChest","type":{"media":"Online-Ressource","bibl":"periodical"},"corporate":[{"display":"American College of Chest Physicians","role":"isb"}],"titleAlt":[{"title":"Diseases of the chest"},{"title":"for pulmonologists, cardiologists, cardiothoracic surgeons, critical care physicians, and related specialists"},{"title":"the cardiopulmonary and critical care journal"},{"title":"for pulmonologists, cardiologists, cardiothoracic surgeons, critical care physicians, and related specialists"}],"language":["eng"],"part":{"pages":"1557-1566","extent":"10","issue":"6","text":"140(2011), 6 vom: Dez., Seite 1557-1566","volume":"140","year":"2011"},"pubHistory":["1.1935 -"],"note":["Gesehen am 09.11.2017"]}],"origin":[{"dateIssuedDisp":"2011","dateIssuedKey":"2011"}],"language":["eng"],"name":{"displayForm":["David E. Ost, MD, MPH; Armin Ernst, MD, FCCP; Xiudong Lei, PhD; David Feller-Kopman, MD, FCCP; George A. Eapen, MD, FCCP; Kevin L. Kovitz MD, FCCP; Felix J.F. Herth, MD, FCCP; and Michael Simoff, MD, FCCP; on behalf of the AQuIRE bronchoscopy registry"]},"person":[{"family":"Ost","role":"aut","given":"David E.","display":"Ost, David E."},{"given":"Armin","display":"Ernst, Armin","family":"Ernst","role":"aut"},{"family":"Lei","role":"aut","display":"Lei, Xiudong","given":"Xiudong"},{"display":"Feller-Kopman, David","given":"David","role":"aut","family":"Feller-Kopman"},{"family":"Eapen","role":"aut","given":"George A.","display":"Eapen, George A."},{"display":"Kovitz, Kevin L.","given":"Kevin L.","role":"aut","family":"Kovitz"},{"family":"Herth","role":"aut","display":"Herth, Felix","given":"Felix"},{"given":"Michael","display":"Simoff, Michael","role":"aut","family":"Simoff"}],"recId":"1818901498","note":["First published online: 16 December 2015","Gesehen am 13.10.2022"]} | ||
| SRT | |a OSTDAVIDEEDIAGNOSTIC2011 | ||