Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres

Purpose: To evaluate safety and efficacy of uterine artery embolization using narrow-size-range polyphosphazene-coated hydrogel microspheres (Embozene, CeloNova Biosciences, Newnan, GA). Methods: Between May 2006 and September 2008, a total of 121 consecutive patients (mean ± SD age 42.1 ± 5.4 years...

Full description

Saved in:
Bibliographic Details
Main Authors: Stampfl, Ulrike (Author) , Radeleff, Boris (Author) , Sommer, Christof-Matthias (Author) , Stampfl, Sibylle (Author) , Dahlke, Angelika (Author) , Bellemann, Nadine (Author) , Kauczor, Hans-Ulrich (Author) , Richter, Götz Martin (Author)
Format: Article (Journal)
Language:English
Published: 2011
In: CardioVascular and interventional radiology
Year: 2011, Volume: 34, Issue: 2, Pages: 295-305
ISSN:1432-086X
DOI:10.1007/s00270-010-9986-8
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00270-010-9986-8
Get full text
Author Notes:Ulrike Stampfl, Boris Radeleff, Christof Sommer, Sibylle Stampfl, Angelika Dahlke, Nadine Bellemann, Hans-Ulrich Kauczor, Goetz M. Richter

MARC

LEADER 00000caa a2200000 c 4500
001 1819472434
003 DE-627
005 20230710110407.0
007 cr uuu---uuuuu
008 221020s2011 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00270-010-9986-8  |2 doi 
035 |a (DE-627)1819472434 
035 |a (DE-599)KXP1819472434 
035 |a (OCoLC)1389766059 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stampfl, Ulrike  |d 1978-  |e VerfasserIn  |0 (DE-588)132557711  |0 (DE-627)523645104  |0 (DE-576)261999664  |4 aut 
245 1 0 |a Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres  |c Ulrike Stampfl, Boris Radeleff, Christof Sommer, Sibylle Stampfl, Angelika Dahlke, Nadine Bellemann, Hans-Ulrich Kauczor, Goetz M. Richter 
264 1 |c 2011 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 15 October 2010 
500 |a Gesehen am 20.10.2022 
520 |a Purpose: To evaluate safety and efficacy of uterine artery embolization using narrow-size-range polyphosphazene-coated hydrogel microspheres (Embozene, CeloNova Biosciences, Newnan, GA). Methods: Between May 2006 and September 2008, a total of 121 consecutive patients (mean ± SD age 42.1 ± 5.4 years, range 30.5–51.5 years) were enrolled onto this single-center study. The primary study endpoint was safety as assessed by the society of interventional radiology (SIR) classification. The secondary endpoint was efficacy, which was based on a 1-year magnetic resonance imaging study and relief of symptoms documented by the Medical Outcomes Study 36-Item Short-Form Health Survey questionnaire over a 2-year interval. Results: The mean ± SD diameter of the dominant fibroid was 6.4 ± 2.6 (range, 2.9–13.9) cm and the mean volume 137.2 ± 245.1 (range, 5.3–1184) ml. Most patients had multiple fibroids with 11% more than 10. A total of 240 of 242 interventions were completed as planned, a technical success rate of 99.2%. According to the SIR classification, one type A, eight type C, and one type D complication occurred. Total devascularization was noted in 96% (116 of 121) of dominant fibroids. Volume decrease was 4% at 2 weeks, 52% (P < 0.001) at 3 months, 78% (P < 0.001) at 6 months, and 91% at 12 months (P < 0.001). The latter difference was statistically significant (P = 0.007). A total of 92% had improved hypermenorrhea at 1 year and 94% at 2 years. Dysmenorrhea was improved in 96% at 1 year and in 95% at 2 years. The overall health status score was 60.4 ± 26.2 points at baseline and 96.9 ± 3.8 after 1 year (P = 0.0019). Conclusion: Uterine artery embolization with Embozene microspheres is a safe procedure. Its efficacy is demonstrated by high fibroid devascularization and volume reduction rates and significant improvements of clinical symptoms and quality-of-life scores during follow-up. 
650 4 |a Fibroid devascularization 
650 4 |a Polyphosphazene-coated microspheres 
650 4 |a Quality of life 
650 4 |a Uterine artery embolization 
650 4 |a Uterine leiomyomata 
700 1 |a Radeleff, Boris  |d 1969-  |e VerfasserIn  |0 (DE-588)123910846  |0 (DE-627)706470826  |0 (DE-576)293938504  |4 aut 
700 1 |a Sommer, Christof-Matthias  |d 1978-  |e VerfasserIn  |0 (DE-588)133929701  |0 (DE-627)558738699  |0 (DE-576)278278035  |4 aut 
700 1 |a Stampfl, Sibylle  |d 1978-  |e VerfasserIn  |0 (DE-588)132567113  |0 (DE-627)523952155  |0 (DE-576)262000288  |4 aut 
700 1 |a Dahlke, Angelika  |e VerfasserIn  |4 aut 
700 1 |a Bellemann, Nadine  |d 1982-  |e VerfasserIn  |0 (DE-588)140128069  |0 (DE-627)616037562  |0 (DE-576)314703993  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Richter, Götz Martin  |e VerfasserIn  |0 (DE-588)1068606568  |0 (DE-627)820513555  |0 (DE-576)427924057  |4 aut 
773 0 8 |i Enthalten in  |t CardioVascular and interventional radiology  |d Berlin : Springer, 1978  |g 34(2011), 2, Seite 295-305  |h Online-Ressource  |w (DE-627)253390451  |w (DE-600)1458490-6  |w (DE-576)072283483  |x 1432-086X  |7 nnas  |a Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres 
773 1 8 |g volume:34  |g year:2011  |g number:2  |g pages:295-305  |g extent:11  |a Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres 
856 4 0 |u https://doi.org/10.1007/s00270-010-9986-8  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20221020 
993 |a Article 
994 |a 2011 
998 |g 1068606568  |a Richter, Götz Martin  |m 1068606568:Richter, Götz Martin  |d 50000  |e 50000PR1068606568  |k 0/50000/  |p 8  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 140128069  |a Bellemann, Nadine  |m 140128069:Bellemann, Nadine  |d 910000  |d 911400  |e 910000PB140128069  |e 911400PB140128069  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 132567113  |a Stampfl, Sibylle  |m 132567113:Stampfl, Sibylle  |d 910000  |d 911100  |e 910000PS132567113  |e 911100PS132567113  |k 0/910000/  |k 1/910000/911100/  |p 4 
998 |g 133929701  |a Sommer, Christof-Matthias  |m 133929701:Sommer, Christof-Matthias  |d 910000  |d 911400  |e 910000PS133929701  |e 911400PS133929701  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 123910846  |a Radeleff, Boris  |m 123910846:Radeleff, Boris  |d 910000  |d 911400  |e 910000PR123910846  |e 911400PR123910846  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 132557711  |a Stampfl, Ulrike  |m 132557711:Stampfl, Ulrike  |d 910000  |d 911400  |e 910000PS132557711  |e 911400PS132557711  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1819472434  |e 4199414797 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1819472434","physDesc":[{"extent":"11 S."}],"title":[{"title":"Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres","title_sort":"Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Online veröffentlicht: 15 October 2010","Gesehen am 20.10.2022"],"origin":[{"dateIssuedDisp":"2011","dateIssuedKey":"2011"}],"person":[{"display":"Stampfl, Ulrike","role":"aut","given":"Ulrike","family":"Stampfl"},{"given":"Boris","role":"aut","family":"Radeleff","display":"Radeleff, Boris"},{"display":"Sommer, Christof-Matthias","family":"Sommer","given":"Christof-Matthias","role":"aut"},{"family":"Stampfl","role":"aut","given":"Sibylle","display":"Stampfl, Sibylle"},{"role":"aut","given":"Angelika","family":"Dahlke","display":"Dahlke, Angelika"},{"display":"Bellemann, Nadine","role":"aut","given":"Nadine","family":"Bellemann"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","given":"Hans-Ulrich","role":"aut"},{"display":"Richter, Götz Martin","given":"Götz Martin","role":"aut","family":"Richter"}],"relHost":[{"id":{"zdb":["1458490-6"],"issn":["1432-086X"],"eki":["253390451"]},"part":{"pages":"295-305","text":"34(2011), 2, Seite 295-305","extent":"11","issue":"2","year":"2011","volume":"34"},"titleAlt":[{"title":"CVIR"},{"title":"Cardiovascular radiology"},{"title":"CardioVascular & interventional radiology"}],"pubHistory":["1.1978 -"],"title":[{"subtitle":"CVIR","title_sort":"CardioVascular and interventional radiology","title":"CardioVascular and interventional radiology"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 27. November 2017","Fortsetzung der Druck-Ausgabe","Ungezählte Beil. ab 20.1997: Supplement"],"origin":[{"publisher":"Springer ; Springer","dateIssuedKey":"1978","dateIssuedDisp":"1978-","publisherPlace":"Berlin ; Heidelberg ; New York, NY"}],"disp":"Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheresCardioVascular and interventional radiology","recId":"253390451","physDesc":[{"extent":"Online-Ressource"}]}],"id":{"doi":["10.1007/s00270-010-9986-8"],"eki":["1819472434"]},"name":{"displayForm":["Ulrike Stampfl, Boris Radeleff, Christof Sommer, Sibylle Stampfl, Angelika Dahlke, Nadine Bellemann, Hans-Ulrich Kauczor, Goetz M. Richter"]}} 
SRT |a STAMPFLULRMIDTERMRES2011