In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

Objective - We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. - Background - Early identification of in-stent restenosis (ISR) is important to avoid recurrent is...

Full description

Saved in:
Bibliographic Details
Main Authors: Steen, Henning (Author) , André, Florian (Author) , Korosoglou, Grigorios (Author) , Mueller, Dirk (Author) , Hosch, Waldemar P. (Author) , Kauczor, Hans-Ulrich (Author) , Giannitsis, Evangelos (Author) , Katus, Hugo (Author)
Format: Article (Journal)
Language:English
Published: 2011
In: European journal of radiology
Year: 2011, Volume: 80, Issue: 1, Pages: 143-150
ISSN:1872-7727
DOI:10.1016/j.ejrad.2010.08.007
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2010.08.007
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X10003748
Get full text
Author Notes:Henning Steen, Florian André, Grigorios Korosoglou, Dirk Mueller, Waldemar Hosch, Hans-Ulrich Kauczor, Evangelos Giannitsis, Hugo A. Katus

MARC

LEADER 00000caa a2200000 c 4500
001 1819613593
003 DE-627
005 20230710110313.0
007 cr uuu---uuuuu
008 221021s2011 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2010.08.007  |2 doi 
035 |a (DE-627)1819613593 
035 |a (DE-599)KXP1819613593 
035 |a (OCoLC)1389766064 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Steen, Henning  |d 1972-  |e VerfasserIn  |0 (DE-588)123681669  |0 (DE-627)706393600  |0 (DE-576)293824851  |4 aut 
245 1 0 |a In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT  |c Henning Steen, Florian André, Grigorios Korosoglou, Dirk Mueller, Waldemar Hosch, Hans-Ulrich Kauczor, Evangelos Giannitsis, Hugo A. Katus 
264 1 |c 2011 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar: 3 September 2010 
500 |a Gesehen am 21.10.2022 
520 |a Objective - We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. - Background - Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. - Material and methods - Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5mm; group B=2.75-3.0mm; group C=3.5-4.0mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation=128mm×0.625mm; rotation time=270ms; tube current=800mAs with 120kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values <0.05 were regarded statistically significant. - Results - In-stent lumen diameter >60% for group C stents was significantly larger and CNR was significantly lower (both p<0.05) for sharp kernels (CD; XCD) when compared to groups A/B. The FWHM-method showed significantly smaller in-stent lumen diameter (p<0.05) when compared to the manual method. - Conclusion - 256-MDCT could potentially be employed for clinical assessment of stent patency in stents >3.0mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen. 
650 4 |a Artifacts 
650 4 |a Coronary artery disease 
650 4 |a Coronary stents 
650 4 |a CT angiography 
650 4 |a In-stent 
650 4 |a Multislice CT 
650 4 |a Restenosis 
700 1 |a André, Florian  |d 1983-  |e VerfasserIn  |0 (DE-588)1051060230  |0 (DE-627)785671714  |0 (DE-576)405733267  |4 aut 
700 1 |a Korosoglou, Grigorios  |d 1976-  |e VerfasserIn  |0 (DE-588)12854225X  |0 (DE-627)374709025  |0 (DE-576)297204912  |4 aut 
700 1 |a Mueller, Dirk  |e VerfasserIn  |4 aut 
700 1 |a Hosch, Waldemar P.  |d 1969-  |e VerfasserIn  |0 (DE-588)11585696X  |0 (DE-627)691639205  |0 (DE-576)290116562  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Giannitsis, Evangelos  |e VerfasserIn  |0 (DE-588)113336241  |0 (DE-627)577184091  |0 (DE-576)289759579  |4 aut 
700 1 |a Katus, Hugo  |d 1951-  |e VerfasserIn  |0 (DE-588)108916618  |0 (DE-627)577155040  |0 (DE-576)289625076  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 80(2011), 1, Seite 143-150  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT 
773 1 8 |g volume:80  |g year:2011  |g number:1  |g pages:143-150  |g extent:8  |a In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT 
856 4 0 |u https://doi.org/10.1016/j.ejrad.2010.08.007  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0720048X10003748  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20221021 
993 |a Article 
994 |a 2011 
998 |g 108916618  |a Katus, Hugo  |m 108916618:Katus, Hugo  |d 910000  |d 910100  |e 910000PK108916618  |e 910100PK108916618  |k 0/910000/  |k 1/910000/910100/  |p 8  |y j 
998 |g 113336241  |a Giannitsis, Evangelos  |m 113336241:Giannitsis, Evangelos  |d 910000  |d 910100  |d 50000  |e 910000PG113336241  |e 910100PG113336241  |e 50000PG113336241  |k 0/910000/  |k 1/910000/910100/  |k 0/50000/  |p 7 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 11585696X  |a Hosch, Waldemar P.  |m 11585696X:Hosch, Waldemar P.  |d 50000  |e 50000PH11585696X  |k 0/50000/  |p 5 
998 |g 12854225X  |a Korosoglou, Grigorios  |m 12854225X:Korosoglou, Grigorios  |d 50000  |e 50000PK12854225X  |k 0/50000/  |p 3 
998 |g 1051060230  |a André, Florian  |m 1051060230:André, Florian  |d 910000  |d 910100  |e 910000PA1051060230  |e 910100PA1051060230  |k 0/910000/  |k 1/910000/910100/  |p 2 
998 |g 123681669  |a Steen, Henning  |m 123681669:Steen, Henning  |d 50000  |e 50000PS123681669  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1819613593  |e 420056128X 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"name":{"displayForm":["Henning Steen, Florian André, Grigorios Korosoglou, Dirk Mueller, Waldemar Hosch, Hans-Ulrich Kauczor, Evangelos Giannitsis, Hugo A. Katus"]},"note":["Online verfügbar: 3 September 2010","Gesehen am 21.10.2022"],"recId":"1819613593","person":[{"family":"Steen","role":"aut","given":"Henning","display":"Steen, Henning"},{"given":"Florian","display":"André, Florian","role":"aut","family":"André"},{"family":"Korosoglou","role":"aut","display":"Korosoglou, Grigorios","given":"Grigorios"},{"role":"aut","family":"Mueller","given":"Dirk","display":"Mueller, Dirk"},{"given":"Waldemar P.","display":"Hosch, Waldemar P.","role":"aut","family":"Hosch"},{"role":"aut","family":"Kauczor","given":"Hans-Ulrich","display":"Kauczor, Hans-Ulrich"},{"family":"Giannitsis","role":"aut","given":"Evangelos","display":"Giannitsis, Evangelos"},{"role":"aut","family":"Katus","given":"Hugo","display":"Katus, Hugo"}],"id":{"eki":["1819613593"],"doi":["10.1016/j.ejrad.2010.08.007"]},"physDesc":[{"extent":"8 S."}],"title":[{"title_sort":"In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT","title":"In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"2011"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2005350-2"],"issn":["1872-7727"],"eki":["32044483X"]},"title":[{"subtitle":"EJR","title":"European journal of radiology","title_sort":"European journal of radiology"}],"origin":[{"dateIssuedDisp":"1990-","publisher":"Elsevier Science","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990"}],"recId":"32044483X","disp":"In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CTEuropean journal of radiology","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"EJR"}],"part":{"volume":"80","year":"2011","extent":"8","pages":"143-150","issue":"1","text":"80(2011), 1, Seite 143-150"},"language":["eng"],"note":["Gesehen am 05.02.20"],"pubHistory":["Nachgewiesen 10.1990 -"]}]} 
SRT |a STEENHENNIINVITROEVA2011