Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy: multi-institutional planning study for head-and-neck cases

Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wiezorek, Tilo (VerfasserIn) , Brachwitz, Tim (VerfasserIn) , Georg, Dietmar (VerfasserIn) , Blank, Eyck (VerfasserIn) , Fotina, Irina (VerfasserIn) , Habl, Gregor (VerfasserIn) , Kretschmer, Matthias (VerfasserIn) , Lutters, Gerd (VerfasserIn) , Salz, Henning (VerfasserIn) , Schubert, Kai (VerfasserIn) , Wagner, Daniela (VerfasserIn) , Wendt, Thomas G. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 21 February 2011
In: Radiation oncology
Year: 2011, Jahrgang: 6, Pages: 1-10
ISSN:1748-717X
DOI:10.1186/1748-717X-6-20
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1186/1748-717X-6-20
Volltext
Verfasserangaben:Tilo Wiezorek, Tim Brachwitz, Dietmar Georg, Eyck Blank, Irina Fotina, Gregor Habl, Matthias Kretschmer, Gerd Lutters, Henning Salz, Kai Schubert, Daniela Wagner, Thomas G. Wendt

MARC

LEADER 00000caa a2200000 c 4500
001 1820692329
003 DE-627
005 20230710103400.0
007 cr uuu---uuuuu
008 221103s2011 xx |||||o 00| ||eng c
024 7 |a 10.1186/1748-717X-6-20  |2 doi 
035 |a (DE-627)1820692329 
035 |a (DE-599)KXP1820692329 
035 |a (OCoLC)1389755716 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wiezorek, Tilo  |d 1965-  |e VerfasserIn  |0 (DE-588)121990761  |0 (DE-627)081667345  |0 (DE-576)187833664  |4 aut 
245 1 0 |a Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy  |b multi-institutional planning study for head-and-neck cases  |c Tilo Wiezorek, Tim Brachwitz, Dietmar Georg, Eyck Blank, Irina Fotina, Gregor Habl, Matthias Kretschmer, Gerd Lutters, Henning Salz, Kai Schubert, Daniela Wagner, Thomas G. Wendt 
264 1 |c 21 February 2011 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.11.2022 
520 |a Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. 
650 4 |a Helical Tomotherapy 
650 4 |a Monitor Unit 
650 4 |a Parotid Gland 
650 4 |a Planning Target Volume 
650 4 |a Treatment Planning System 
700 1 |a Brachwitz, Tim  |e VerfasserIn  |4 aut 
700 1 |a Georg, Dietmar  |e VerfasserIn  |4 aut 
700 1 |a Blank, Eyck  |e VerfasserIn  |4 aut 
700 1 |a Fotina, Irina  |e VerfasserIn  |4 aut 
700 1 |a Habl, Gregor  |d 1977-  |e VerfasserIn  |0 (DE-588)141668008  |0 (DE-627)630411743  |0 (DE-576)325046158  |4 aut 
700 1 |a Kretschmer, Matthias  |e VerfasserIn  |4 aut 
700 1 |a Lutters, Gerd  |e VerfasserIn  |4 aut 
700 1 |a Salz, Henning  |e VerfasserIn  |4 aut 
700 1 |a Schubert, Kai  |d 1967-  |e VerfasserIn  |0 (DE-588)1083291157  |0 (DE-627)847939901  |0 (DE-576)455687765  |4 aut 
700 1 |a Wagner, Daniela  |e VerfasserIn  |4 aut 
700 1 |a Wendt, Thomas G.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Radiation oncology  |d London : BioMed Central, 2006  |g 6(2011), Artikel-ID 20, Seite 1-10  |h Online-Ressource  |w (DE-627)508725739  |w (DE-600)2224965-5  |w (DE-576)260614815  |x 1748-717X  |7 nnas  |a Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy multi-institutional planning study for head-and-neck cases 
773 1 8 |g volume:6  |g year:2011  |g elocationid:20  |g pages:1-10  |g extent:10  |a Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy multi-institutional planning study for head-and-neck cases 
856 4 0 |u https://doi.org/10.1186/1748-717X-6-20  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20221103 
993 |a Article 
994 |a 2011 
998 |g 1083291157  |a Schubert, Kai  |m 1083291157:Schubert, Kai  |d 910000  |d 911400  |e 910000PS1083291157  |e 911400PS1083291157  |k 0/910000/  |k 1/910000/911400/  |p 10 
998 |g 141668008  |a Habl, Gregor  |m 141668008:Habl, Gregor  |d 910000  |d 911400  |e 910000PH141668008  |e 911400PH141668008  |k 0/910000/  |k 1/910000/911400/  |p 6 
999 |a KXP-PPN1820692329  |e 4206053081 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","roleDisplay":"VerfasserIn","display":"Wiezorek, Tilo","given":"Tilo","family":"Wiezorek"},{"given":"Tim","family":"Brachwitz","role":"aut","display":"Brachwitz, Tim","roleDisplay":"VerfasserIn"},{"family":"Georg","given":"Dietmar","roleDisplay":"VerfasserIn","display":"Georg, Dietmar","role":"aut"},{"role":"aut","display":"Blank, Eyck","roleDisplay":"VerfasserIn","given":"Eyck","family":"Blank"},{"family":"Fotina","given":"Irina","display":"Fotina, Irina","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Gregor","family":"Habl","role":"aut","display":"Habl, Gregor","roleDisplay":"VerfasserIn"},{"family":"Kretschmer","given":"Matthias","roleDisplay":"VerfasserIn","display":"Kretschmer, Matthias","role":"aut"},{"given":"Gerd","family":"Lutters","role":"aut","display":"Lutters, Gerd","roleDisplay":"VerfasserIn"},{"family":"Salz","given":"Henning","display":"Salz, Henning","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","display":"Schubert, Kai","roleDisplay":"VerfasserIn","given":"Kai","family":"Schubert"},{"family":"Wagner","given":"Daniela","display":"Wagner, Daniela","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Thomas G.","family":"Wendt","role":"aut","roleDisplay":"VerfasserIn","display":"Wendt, Thomas G."}],"title":[{"title_sort":"Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy","title":"Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy","subtitle":"multi-institutional planning study for head-and-neck cases"}],"language":["eng"],"recId":"1820692329","type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 03.11.2022"],"name":{"displayForm":["Tilo Wiezorek, Tim Brachwitz, Dietmar Georg, Eyck Blank, Irina Fotina, Gregor Habl, Matthias Kretschmer, Gerd Lutters, Henning Salz, Kai Schubert, Daniela Wagner, Thomas G. Wendt"]},"id":{"doi":["10.1186/1748-717X-6-20"],"eki":["1820692329"]},"origin":[{"dateIssuedDisp":"21 February 2011","dateIssuedKey":"2011"}],"relHost":[{"id":{"zdb":["2224965-5"],"eki":["508725739"],"issn":["1748-717X"]},"origin":[{"publisher":"BioMed Central","dateIssuedKey":"2006","dateIssuedDisp":"2006-","publisherPlace":"London"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Radiation oncology","title_sort":"Radiation oncology"}],"part":{"extent":"10","volume":"6","text":"6(2011), Artikel-ID 20, Seite 1-10","pages":"1-10","year":"2011"},"pubHistory":["1.2006 -"],"language":["eng"],"recId":"508725739","note":["Gesehen am 06.09.10"],"disp":"Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy multi-institutional planning study for head-and-neck casesRadiation oncology","type":{"media":"Online-Ressource","bibl":"periodical"}}],"physDesc":[{"extent":"10 S."}]} 
SRT |a WIEZOREKTIROTATIONAL2120