Limitations of nasal nitric oxide measurement for diagnosis of primary ciliary dyskinesia with normal ultrastructure

Rationale: Primary ciliary dyskinesia (PCD) is a heterogeneous, multisystem disorder characterized by defective ciliary beating. Diagnostic guidelines of the American Thoracic Society and European Respiratory Society recommend measurement of nasal nitric oxide (nNO) for PCD diagnosis. Several studie...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Raidt, Johanna Felicitas (VerfasserIn) , Krenz, Henrike (VerfasserIn) , Tebbe, Johannes (VerfasserIn) , Grosse-Onnebrink, Joerg (VerfasserIn) , Olbrich, Heike (VerfasserIn) , Loges, Niki Tomas (VerfasserIn) , Biebach, Luisa (VerfasserIn) , Schmalstieg, Christian (VerfasserIn) , Kessler, Christina (VerfasserIn) , Wallmeier, Julia (VerfasserIn) , Dworniczak, Bernd (VerfasserIn) , Pennekamp, Petra (VerfasserIn) , Dugas, Martin (VerfasserIn) , Werner, Claudius (VerfasserIn) , Omran, Heymut (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 2022
In: Annals of the American Thoracic Society
Year: 2022, Jahrgang: 19, Heft: 8, Pages: 1275-1284
ISSN:2325-6621
DOI:10.1513/AnnalsATS.202106-728OC
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1513/AnnalsATS.202106-728OC
Verlag, lizenzpflichtig, Volltext: https://www.atsjournals.org/doi/10.1513/AnnalsATS.202106-728OC
Volltext
Verfasserangaben:Johanna Raidt, Henrike Krenz, Johannes Tebbe, Joerg Grosse-Onnebrink, Heike Olbrich, Niki Tomas Loges, Luisa Biebach, Christian Schmalstieg, Christina Kessler, Julia Wallmeier, Bernd Dworniczak, Petra Pennekamp, Martin Dugas, Claudius Werner, Heymut Omran

MARC

LEADER 00000caa a2200000 c 4500
001 1821539001
003 DE-627
005 20230118132746.0
007 cr uuu---uuuuu
008 221110s2022 xx |||||o 00| ||eng c
024 7 |a 10.1513/AnnalsATS.202106-728OC  |2 doi 
035 |a (DE-627)1821539001 
035 |a (DE-599)KXP1821539001 
035 |a (OCoLC)1361692987 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Raidt, Johanna Felicitas  |d 1984-  |e VerfasserIn  |0 (DE-588)1073667995  |0 (DE-627)829327347  |0 (DE-576)435252607  |4 aut 
245 1 0 |a Limitations of nasal nitric oxide measurement for diagnosis of primary ciliary dyskinesia with normal ultrastructure  |c Johanna Raidt, Henrike Krenz, Johannes Tebbe, Joerg Grosse-Onnebrink, Heike Olbrich, Niki Tomas Loges, Luisa Biebach, Christian Schmalstieg, Christina Kessler, Julia Wallmeier, Bernd Dworniczak, Petra Pennekamp, Martin Dugas, Claudius Werner, Heymut Omran 
264 1 |c August 2022 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 10.11.2022 
520 |a Rationale: Primary ciliary dyskinesia (PCD) is a heterogeneous, multisystem disorder characterized by defective ciliary beating. Diagnostic guidelines of the American Thoracic Society and European Respiratory Society recommend measurement of nasal nitric oxide (nNO) for PCD diagnosis. Several studies demonstrated low nNO production rates in PCD individuals, but underlying causes remain elusive. Objectives: To determine nNO production rates in a well-characterized PCD cohort, including subgroup analyses with regard to ultrastructural and ciliary beating phenotypes. Methods: This study included 301 individuals assessed according to European Respiratory Society guidelines. Diagnostic cutoffs for nNO production rates for this study cohort and subgroups with normal and abnormal ultrastructure were determined. Diagnostic accuracy was also tested for the widely used 77 nl/min cutoff in this study cohort. The relationship between nNO production rates and ciliary beat frequencies (CBFs) was evaluated. Results: The study cohort comprised 180 individuals with definite PCD diagnosis, including 160 individuals with genetic diagnosis, 16 individuals with probable PCD diagnosis, and 105 disease controls. The 77 nl/min nNO cutoff showed a test sensitivity of 0.92 and specificity of 0.86. Test sensitivity was lower (0.85) in the subgroup of 47 PCD individuals with normal ultrastructure compared with 133 PCD individuals with abnormal ultrastructure (0.95). The optimal diagnostic cutoff for the nNO production rate for the whole study cohort was 69.8 nl/min (sensitivity, 0.92; specificity, 0.89); however, it was 107.8 nl/min (sensitivity, 0.89; specificity, 0.78) for the subgroup of PCD with normal ultrastructure. PCD individuals with normal ultrastructure compared with abnormal ultrastructure showed higher ciliary motility. Consistently, PCD individuals with higher CBFs showed higher nNO production rates. In addition, laterality defects occurred less frequently in PCD with normal ultrastructure. Conclusions: Measurements of nNO below the widely used 77 nl/min cutoff are less sensitive in detecting PCD individuals with normal ultrastructure. Our findings indicate that higher nNO production in this subgroup with a higher cutoff for the nNO production rate (107.8 nl/min) and higher residual ciliary motility is dependent on the underlying molecular PCD defect. Higher nNO production rates, higher residual CBFs, and the lower prevalence of laterality defects hamper diagnosis of PCD with normal ultrastructure. Adjusting the cutoff of nNO production rate to 107.8 nl/min might promote diagnosing PCD with normal ultrastructure. 
650 4 |a accuracy 
650 4 |a cilia 
650 4 |a ciliary beat frequency 
650 4 |a genetic 
650 4 |a mutations 
650 4 |a prevalence 
650 4 |a transmission electron-microscopy 
650 4 |a variants 
700 1 |a Krenz, Henrike  |e VerfasserIn  |4 aut 
700 1 |a Tebbe, Johannes  |e VerfasserIn  |4 aut 
700 1 |a Grosse-Onnebrink, Joerg  |e VerfasserIn  |4 aut 
700 1 |a Olbrich, Heike  |e VerfasserIn  |4 aut 
700 1 |a Loges, Niki Tomas  |e VerfasserIn  |4 aut 
700 1 |a Biebach, Luisa  |e VerfasserIn  |4 aut 
700 1 |a Schmalstieg, Christian  |e VerfasserIn  |4 aut 
700 1 |a Kessler, Christina  |e VerfasserIn  |4 aut 
700 1 |a Wallmeier, Julia  |e VerfasserIn  |4 aut 
700 1 |a Dworniczak, Bernd  |e VerfasserIn  |4 aut 
700 1 |a Pennekamp, Petra  |d 1966-  |e VerfasserIn  |0 (DE-588)122780140  |0 (DE-627)70604066X  |0 (DE-576)293417881  |4 aut 
700 1 |a Dugas, Martin  |e VerfasserIn  |0 (DE-588)1131361393  |0 (DE-627)886028701  |0 (DE-576)487948939  |4 aut 
700 1 |a Werner, Claudius  |e VerfasserIn  |4 aut 
700 1 |a Omran, Heymut  |d 1967-  |e VerfasserIn  |0 (DE-588)114700427  |0 (DE-627)390016381  |0 (DE-576)173269966  |4 aut 
773 0 8 |i Enthalten in  |a American Thoracic Society  |t Annals of the American Thoracic Society  |d New York, NY : American Thoracic Society, 2013  |g 19(2022), 8, Seite 1275-1284  |h Online-Ressource  |w (DE-627)736121897  |w (DE-600)2702474-X  |w (DE-576)378731726  |x 2325-6621  |7 nnas 
773 1 8 |g volume:19  |g year:2022  |g number:8  |g pages:1275-1284  |g extent:10  |a Limitations of nasal nitric oxide measurement for diagnosis of primary ciliary dyskinesia with normal ultrastructure 
856 4 0 |u https://doi.org/10.1513/AnnalsATS.202106-728OC  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.atsjournals.org/doi/10.1513/AnnalsATS.202106-728OC  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20221110 
993 |a Article 
994 |a 2022 
998 |g 1131361393  |a Dugas, Martin  |m 1131361393:Dugas, Martin  |d 910000  |d 911810  |e 910000PD1131361393  |e 911810PD1131361393  |k 0/910000/  |k 1/910000/911810/  |p 13 
999 |a KXP-PPN1821539001  |e 4208433159 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"family":"Raidt","display":"Raidt, Johanna Felicitas","given":"Johanna Felicitas","role":"aut"},{"given":"Henrike","role":"aut","display":"Krenz, Henrike","family":"Krenz"},{"display":"Tebbe, Johannes","family":"Tebbe","role":"aut","given":"Johannes"},{"given":"Joerg","role":"aut","family":"Grosse-Onnebrink","display":"Grosse-Onnebrink, Joerg"},{"role":"aut","given":"Heike","family":"Olbrich","display":"Olbrich, Heike"},{"display":"Loges, Niki Tomas","family":"Loges","role":"aut","given":"Niki Tomas"},{"display":"Biebach, Luisa","family":"Biebach","role":"aut","given":"Luisa"},{"family":"Schmalstieg","display":"Schmalstieg, Christian","role":"aut","given":"Christian"},{"display":"Kessler, Christina","family":"Kessler","role":"aut","given":"Christina"},{"role":"aut","given":"Julia","family":"Wallmeier","display":"Wallmeier, Julia"},{"family":"Dworniczak","display":"Dworniczak, Bernd","given":"Bernd","role":"aut"},{"given":"Petra","role":"aut","family":"Pennekamp","display":"Pennekamp, Petra"},{"role":"aut","given":"Martin","display":"Dugas, Martin","family":"Dugas"},{"family":"Werner","display":"Werner, Claudius","given":"Claudius","role":"aut"},{"given":"Heymut","role":"aut","family":"Omran","display":"Omran, Heymut"}],"language":["eng"],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"August 2022"}],"note":["Gesehen am 10.11.2022"],"title":[{"title_sort":"Limitations of nasal nitric oxide measurement for diagnosis of primary ciliary dyskinesia with normal ultrastructure","title":"Limitations of nasal nitric oxide measurement for diagnosis of primary ciliary dyskinesia with normal ultrastructure"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1821539001","physDesc":[{"extent":"10 S."}],"name":{"displayForm":["Johanna Raidt, Henrike Krenz, Johannes Tebbe, Joerg Grosse-Onnebrink, Heike Olbrich, Niki Tomas Loges, Luisa Biebach, Christian Schmalstieg, Christina Kessler, Julia Wallmeier, Bernd Dworniczak, Petra Pennekamp, Martin Dugas, Claudius Werner, Heymut Omran"]},"id":{"doi":["10.1513/AnnalsATS.202106-728OC"],"eki":["1821539001"]},"relHost":[{"corporate":[{"role":"aut","display":"American Thoracic Society"}],"disp":"American Thoracic SocietyAnnals of the American Thoracic Society","origin":[{"dateIssuedDisp":"2013-","publisherPlace":"New York, NY","dateIssuedKey":"2013","publisher":"American Thoracic Society"}],"note":["Gesehen 05.10.2018"],"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"AnnalsATS"}],"title":[{"title":"Annals of the American Thoracic Society","title_sort":"Annals of the American Thoracic Society"}],"part":{"volume":"19","extent":"10","text":"19(2022), 8, Seite 1275-1284","pages":"1275-1284","year":"2022","issue":"8"},"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["10.2013 -"],"recId":"736121897","id":{"zdb":["2702474-X"],"eki":["736121897"],"issn":["2325-6621"]}}]} 
SRT |a RAIDTJOHANLIMITATION2022