Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre
The Heidelberg Ion-Beam Therapy Centre???s synchrotron makes use of the well established slow extraction RF KO method near the third-order resonance. The spill quality is essential for therapy, since the reproducibility and fidelity in the parameters of the extracted beam translate in a reduction of...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
1 October 2022
|
| In: |
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2022, Jahrgang: 1040, Pages: 1-9 |
| ISSN: | 1872-9576 |
| DOI: | 10.1016/j.nima.2022.167137 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.nima.2022.167137 Verlag, lizenzpflichtig, Volltext: https://linkinghub.elsevier.com/retrieve/pii/S0168900222005228 |
| Verfasserangaben: | E.C. Cortés García, E. Feldmeier, M. Galonska, C. Schömers, M. Hun, S. Brons, R. Cee, S. Scheloske, A. Peters, Th. Haberer |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1823518907 | ||
| 003 | DE-627 | ||
| 005 | 20230118125457.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 221124s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.nima.2022.167137 |2 doi | |
| 035 | |a (DE-627)1823518907 | ||
| 035 | |a (DE-599)KXP1823518907 | ||
| 035 | |a (OCoLC)1361692054 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Cortés García, Edgar Cristopher |e VerfasserIn |0 (DE-588)1264091745 |0 (DE-627)1812529066 |4 aut | |
| 245 | 1 | 0 | |a Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre |c E.C. Cortés García, E. Feldmeier, M. Galonska, C. Schömers, M. Hun, S. Brons, R. Cee, S. Scheloske, A. Peters, Th. Haberer |
| 264 | 1 | |c 1 October 2022 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 24.11.2022 | ||
| 520 | |a The Heidelberg Ion-Beam Therapy Centre???s synchrotron makes use of the well established slow extraction RF KO method near the third-order resonance. The spill quality is essential for therapy, since the reproducibility and fidelity in the parameters of the extracted beam translate in a reduction of irradiation time. The horizontal beam response was studied experimentally and with simulations at extraction conditions in order to deduce regions of interest for an optimal excitation signal spectrum. Two narrow frequency regions were found near the betatron resonance. With these results a new signal was engineered for the emittance blow-up scheme. The new excitation signal improves significantly the spill quality for the extraction configurations; for instance the lower interquartile value of the spill duty factor distribution for the most rigid carbon-ion beam E-kin = 430 MeV/u improves from 82.2% to 94.8%. For the proton beam the improvement is more significant, where the spill duty factor is kept over the 90% level. | ||
| 650 | 4 | |a Beam Transfer Function | |
| 650 | 4 | |a extraction | |
| 650 | 4 | |a Hadrontherapy | |
| 650 | 4 | |a RF KO slow extraction | |
| 650 | 4 | |a ripple | |
| 650 | 4 | |a Synchrotron | |
| 650 | 4 | |a system | |
| 700 | 1 | |a Feldmeier, Eike |d 1979- |e VerfasserIn |0 (DE-588)1045115800 |0 (DE-627)77381356X |0 (DE-576)398668620 |4 aut | |
| 700 | 1 | |a Galonska, Michael |d 1970- |e VerfasserIn |0 (DE-588)1013630459 |0 (DE-627)664627226 |0 (DE-576)347463878 |4 aut | |
| 700 | 1 | |a Schömers, Christian |d 1983- |e VerfasserIn |0 (DE-588)1045651885 |0 (DE-627)774687509 |0 (DE-576)399130616 |4 aut | |
| 700 | 1 | |a Hun, M. |e VerfasserIn |4 aut | |
| 700 | 1 | |a Brons, Stephan |e VerfasserIn |0 (DE-588)1072782375 |0 (DE-627)828233594 |0 (DE-576)434240478 |4 aut | |
| 700 | 1 | |a Cee, Rainer |e VerfasserIn |0 (DE-588)1247381145 |0 (DE-627)1781981574 |4 aut | |
| 700 | 1 | |a Scheloske, Stefan |e VerfasserIn |0 (DE-588)1136684956 |0 (DE-627)893451959 |0 (DE-576)490782450 |4 aut | |
| 700 | 1 | |a Peters, Andreas |d 1982- |e VerfasserIn |0 (DE-588)143674587 |0 (DE-627)704565943 |0 (DE-576)338312617 |4 aut | |
| 700 | 1 | |a Haberer, Thomas |d 1960- |e VerfasserIn |0 (DE-588)123579198 |0 (DE-627)706353714 |0 (DE-576)214902188 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |d [Amsterdam] : Elsevier, 1984 |g 1040(2022), Artikel-ID 167137, Seite 1-9 |h Online-Ressource |w (DE-627)266014666 |w (DE-600)1466532-3 |w (DE-576)074959743 |x 1872-9576 |7 nnas |a Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre |
| 773 | 1 | 8 | |g volume:1040 |g year:2022 |g elocationid:167137 |g pages:1-9 |g extent:9 |a Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.nima.2022.167137 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://linkinghub.elsevier.com/retrieve/pii/S0168900222005228 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20221124 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 123579198 |a Haberer, Thomas |m 123579198:Haberer, Thomas |d 910000 |d 950000 |d 950400 |e 910000PH123579198 |e 950000PH123579198 |e 950400PH123579198 |k 0/910000/ |k 1/910000/950000/ |k 2/910000/950000/950400/ |p 10 |y j | ||
| 998 | |g 143674587 |a Peters, Andreas |m 143674587:Peters, Andreas |d 910000 |d 910200 |d 50000 |e 910000PP143674587 |e 910200PP143674587 |e 50000PP143674587 |k 0/910000/ |k 1/910000/910200/ |k 0/50000/ |p 9 | ||
| 998 | |g 1136684956 |a Scheloske, Stefan |m 1136684956:Scheloske, Stefan |p 8 | ||
| 998 | |g 1247381145 |a Cee, Rainer |m 1247381145:Cee, Rainer |p 7 | ||
| 998 | |g 1072782375 |a Brons, Stephan |m 1072782375:Brons, Stephan |p 6 | ||
| 998 | |g 1045651885 |a Schömers, Christian |m 1045651885:Schömers, Christian |p 4 | ||
| 998 | |g 1013630459 |a Galonska, Michael |m 1013630459:Galonska, Michael |p 3 | ||
| 998 | |g 1045115800 |a Feldmeier, Eike |m 1045115800:Feldmeier, Eike |p 2 | ||
| 998 | |g 1264091745 |a Cortés García, Edgar Cristopher |m 1264091745:Cortés García, Edgar Cristopher |p 1 |x j | ||
| 999 | |a KXP-PPN1823518907 |e 4219112839 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"display":"Cortés García, Edgar Cristopher","role":"aut","family":"Cortés García","given":"Edgar Cristopher"},{"given":"Eike","display":"Feldmeier, Eike","role":"aut","family":"Feldmeier"},{"role":"aut","family":"Galonska","display":"Galonska, Michael","given":"Michael"},{"family":"Schömers","role":"aut","display":"Schömers, Christian","given":"Christian"},{"display":"Hun, M.","role":"aut","family":"Hun","given":"M."},{"given":"Stephan","family":"Brons","role":"aut","display":"Brons, Stephan"},{"given":"Rainer","display":"Cee, Rainer","role":"aut","family":"Cee"},{"given":"Stefan","display":"Scheloske, Stefan","role":"aut","family":"Scheloske"},{"display":"Peters, Andreas","family":"Peters","role":"aut","given":"Andreas"},{"given":"Thomas","role":"aut","family":"Haberer","display":"Haberer, Thomas"}],"note":["Gesehen am 24.11.2022"],"language":["eng"],"name":{"displayForm":["E.C. Cortés García, E. Feldmeier, M. Galonska, C. Schömers, M. Hun, S. Brons, R. Cee, S. Scheloske, A. Peters, Th. Haberer"]},"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"1 October 2022"}],"id":{"eki":["1823518907"],"doi":["10.1016/j.nima.2022.167137"]},"recId":"1823518907","type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"9 S."}],"title":[{"title_sort":"Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre","title":"Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"title":[{"partname":"Accelerators, spectrometers, detectors and associated equipment","title":"Nuclear instruments & methods in physics research","title_sort":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics"}],"part":{"extent":"9","volume":"1040","pages":"1-9","text":"1040(2022), Artikel-ID 167137, Seite 1-9","year":"2022"},"pubHistory":["Nachgewiesen 226.1984 -"],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"note":["Gesehen am 24.05.23"],"language":["eng"],"recId":"266014666","id":{"zdb":["1466532-3"],"eki":["266014666"],"issn":["1872-9576"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy CentreNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","origin":[{"publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedDisp":"1994-","publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedKey":"1994"}]}]} | ||
| SRT | |a CORTESGARCOPTIMIZATI1202 | ||