Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre

The Heidelberg Ion-Beam Therapy Centre???s synchrotron makes use of the well established slow extraction RF KO method near the third-order resonance. The spill quality is essential for therapy, since the reproducibility and fidelity in the parameters of the extracted beam translate in a reduction of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Cortés García, Edgar Cristopher (VerfasserIn) , Feldmeier, Eike (VerfasserIn) , Galonska, Michael (VerfasserIn) , Schömers, Christian (VerfasserIn) , Hun, M. (VerfasserIn) , Brons, Stephan (VerfasserIn) , Cee, Rainer (VerfasserIn) , Scheloske, Stefan (VerfasserIn) , Peters, Andreas (VerfasserIn) , Haberer, Thomas (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1 October 2022
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2022, Jahrgang: 1040, Pages: 1-9
ISSN:1872-9576
DOI:10.1016/j.nima.2022.167137
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.nima.2022.167137
Verlag, lizenzpflichtig, Volltext: https://linkinghub.elsevier.com/retrieve/pii/S0168900222005228
Volltext
Verfasserangaben:E.C. Cortés García, E. Feldmeier, M. Galonska, C. Schömers, M. Hun, S. Brons, R. Cee, S. Scheloske, A. Peters, Th. Haberer

MARC

LEADER 00000caa a2200000 c 4500
001 1823518907
003 DE-627
005 20230118125457.0
007 cr uuu---uuuuu
008 221124s2022 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2022.167137  |2 doi 
035 |a (DE-627)1823518907 
035 |a (DE-599)KXP1823518907 
035 |a (OCoLC)1361692054 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Cortés García, Edgar Cristopher  |e VerfasserIn  |0 (DE-588)1264091745  |0 (DE-627)1812529066  |4 aut 
245 1 0 |a Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre  |c E.C. Cortés García, E. Feldmeier, M. Galonska, C. Schömers, M. Hun, S. Brons, R. Cee, S. Scheloske, A. Peters, Th. Haberer 
264 1 |c 1 October 2022 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 24.11.2022 
520 |a The Heidelberg Ion-Beam Therapy Centre???s synchrotron makes use of the well established slow extraction RF KO method near the third-order resonance. The spill quality is essential for therapy, since the reproducibility and fidelity in the parameters of the extracted beam translate in a reduction of irradiation time. The horizontal beam response was studied experimentally and with simulations at extraction conditions in order to deduce regions of interest for an optimal excitation signal spectrum. Two narrow frequency regions were found near the betatron resonance. With these results a new signal was engineered for the emittance blow-up scheme. The new excitation signal improves significantly the spill quality for the extraction configurations; for instance the lower interquartile value of the spill duty factor distribution for the most rigid carbon-ion beam E-kin = 430 MeV/u improves from 82.2% to 94.8%. For the proton beam the improvement is more significant, where the spill duty factor is kept over the 90% level. 
650 4 |a Beam Transfer Function 
650 4 |a extraction 
650 4 |a Hadrontherapy 
650 4 |a RF KO slow extraction 
650 4 |a ripple 
650 4 |a Synchrotron 
650 4 |a system 
700 1 |a Feldmeier, Eike  |d 1979-  |e VerfasserIn  |0 (DE-588)1045115800  |0 (DE-627)77381356X  |0 (DE-576)398668620  |4 aut 
700 1 |a Galonska, Michael  |d 1970-  |e VerfasserIn  |0 (DE-588)1013630459  |0 (DE-627)664627226  |0 (DE-576)347463878  |4 aut 
700 1 |a Schömers, Christian  |d 1983-  |e VerfasserIn  |0 (DE-588)1045651885  |0 (DE-627)774687509  |0 (DE-576)399130616  |4 aut 
700 1 |a Hun, M.  |e VerfasserIn  |4 aut 
700 1 |a Brons, Stephan  |e VerfasserIn  |0 (DE-588)1072782375  |0 (DE-627)828233594  |0 (DE-576)434240478  |4 aut 
700 1 |a Cee, Rainer  |e VerfasserIn  |0 (DE-588)1247381145  |0 (DE-627)1781981574  |4 aut 
700 1 |a Scheloske, Stefan  |e VerfasserIn  |0 (DE-588)1136684956  |0 (DE-627)893451959  |0 (DE-576)490782450  |4 aut 
700 1 |a Peters, Andreas  |d 1982-  |e VerfasserIn  |0 (DE-588)143674587  |0 (DE-627)704565943  |0 (DE-576)338312617  |4 aut 
700 1 |a Haberer, Thomas  |d 1960-  |e VerfasserIn  |0 (DE-588)123579198  |0 (DE-627)706353714  |0 (DE-576)214902188  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d [Amsterdam] : Elsevier, 1984  |g 1040(2022), Artikel-ID 167137, Seite 1-9  |h Online-Ressource  |w (DE-627)266014666  |w (DE-600)1466532-3  |w (DE-576)074959743  |x 1872-9576  |7 nnas  |a Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre 
773 1 8 |g volume:1040  |g year:2022  |g elocationid:167137  |g pages:1-9  |g extent:9  |a Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre 
856 4 0 |u https://doi.org/10.1016/j.nima.2022.167137  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://linkinghub.elsevier.com/retrieve/pii/S0168900222005228  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20221124 
993 |a Article 
994 |a 2022 
998 |g 123579198  |a Haberer, Thomas  |m 123579198:Haberer, Thomas  |d 910000  |d 950000  |d 950400  |e 910000PH123579198  |e 950000PH123579198  |e 950400PH123579198  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 10  |y j 
998 |g 143674587  |a Peters, Andreas  |m 143674587:Peters, Andreas  |d 910000  |d 910200  |d 50000  |e 910000PP143674587  |e 910200PP143674587  |e 50000PP143674587  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 9 
998 |g 1136684956  |a Scheloske, Stefan  |m 1136684956:Scheloske, Stefan  |p 8 
998 |g 1247381145  |a Cee, Rainer  |m 1247381145:Cee, Rainer  |p 7 
998 |g 1072782375  |a Brons, Stephan  |m 1072782375:Brons, Stephan  |p 6 
998 |g 1045651885  |a Schömers, Christian  |m 1045651885:Schömers, Christian  |p 4 
998 |g 1013630459  |a Galonska, Michael  |m 1013630459:Galonska, Michael  |p 3 
998 |g 1045115800  |a Feldmeier, Eike  |m 1045115800:Feldmeier, Eike  |p 2 
998 |g 1264091745  |a Cortés García, Edgar Cristopher  |m 1264091745:Cortés García, Edgar Cristopher  |p 1  |x j 
999 |a KXP-PPN1823518907  |e 4219112839 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"display":"Cortés García, Edgar Cristopher","role":"aut","family":"Cortés García","given":"Edgar Cristopher"},{"given":"Eike","display":"Feldmeier, Eike","role":"aut","family":"Feldmeier"},{"role":"aut","family":"Galonska","display":"Galonska, Michael","given":"Michael"},{"family":"Schömers","role":"aut","display":"Schömers, Christian","given":"Christian"},{"display":"Hun, M.","role":"aut","family":"Hun","given":"M."},{"given":"Stephan","family":"Brons","role":"aut","display":"Brons, Stephan"},{"given":"Rainer","display":"Cee, Rainer","role":"aut","family":"Cee"},{"given":"Stefan","display":"Scheloske, Stefan","role":"aut","family":"Scheloske"},{"display":"Peters, Andreas","family":"Peters","role":"aut","given":"Andreas"},{"given":"Thomas","role":"aut","family":"Haberer","display":"Haberer, Thomas"}],"note":["Gesehen am 24.11.2022"],"language":["eng"],"name":{"displayForm":["E.C. Cortés García, E. Feldmeier, M. Galonska, C. Schömers, M. Hun, S. Brons, R. Cee, S. Scheloske, A. Peters, Th. Haberer"]},"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"1 October 2022"}],"id":{"eki":["1823518907"],"doi":["10.1016/j.nima.2022.167137"]},"recId":"1823518907","type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"9 S."}],"title":[{"title_sort":"Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre","title":"Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"title":[{"partname":"Accelerators, spectrometers, detectors and associated equipment","title":"Nuclear instruments & methods in physics research","title_sort":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics"}],"part":{"extent":"9","volume":"1040","pages":"1-9","text":"1040(2022), Artikel-ID 167137, Seite 1-9","year":"2022"},"pubHistory":["Nachgewiesen 226.1984 -"],"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"note":["Gesehen am 24.05.23"],"language":["eng"],"recId":"266014666","id":{"zdb":["1466532-3"],"eki":["266014666"],"issn":["1872-9576"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy CentreNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","origin":[{"publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedDisp":"1994-","publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedKey":"1994"}]}]} 
SRT |a CORTESGARCOPTIMIZATI1202