A simple optical tissue clearing pipeline for 3D vasculature imaging of the mediastinal organs in mice

Optical tissue clearing (OTC) methods render tissue transparent by matching the refractive index within a sample to enable three-dimensional (3D) imaging with advanced microscopes. The application of OTC method in mediastinal organs in mice remains poorly understand. Our aim was to establish a simpl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sun, Quanchao (VerfasserIn) , Picascia, Tiziana (VerfasserIn) , Khan, Arif ul Maula (VerfasserIn) , Heuveline, Vincent (VerfasserIn) , Gretz, Norbert (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 06 October 2021
In: International journal of experimental pathology
Year: 2021, Jahrgang: 102, Heft: 4/5, Pages: 218-227
ISSN:1365-2613
DOI:10.1111/iep.12399
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1111/iep.12399
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/iep.12399
Volltext
Verfasserangaben:Quanchao Sun, Picascia Tiziana, Arif ul Maula Khan, Vincent Heuveline, Norbert Gretz

MARC

LEADER 00000caa a2200000 c 4500
001 1823745423
003 DE-627
005 20230426194554.0
007 cr uuu---uuuuu
008 221128s2021 xx |||||o 00| ||eng c
024 7 |a 10.1111/iep.12399  |2 doi 
035 |a (DE-627)1823745423 
035 |a (DE-599)KXP1823745423 
035 |a (OCoLC)1360439498 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Sun, Quanchao  |d 1990-  |e VerfasserIn  |0 (DE-588)1246545772  |0 (DE-627)1779412908  |4 aut 
245 1 2 |a A simple optical tissue clearing pipeline for 3D vasculature imaging of the mediastinal organs in mice  |c Quanchao Sun, Picascia Tiziana, Arif ul Maula Khan, Vincent Heuveline, Norbert Gretz 
264 1 |c 06 October 2021 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 28.11.2022 
520 |a Optical tissue clearing (OTC) methods render tissue transparent by matching the refractive index within a sample to enable three-dimensional (3D) imaging with advanced microscopes. The application of OTC method in mediastinal organs in mice remains poorly understand. Our aim was to establish a simple protocol pipeline for 3D imaging of the mediastinal organs in mice. Trachea, oesophagus, thymus and heart were harvested from mice after retrograde perfusion via the abdominal aorta. We combined and optimized antibody labelling of thick tissue samples, OTC with cheap and non-toxic solvent ethyl cinnamate (ECi), and light-sheet fluorescence microscopy (LSFM) or laser confocal fluorescence microscopy (LCFM) to visualize the vasculature of those tissues. A high degree of optical transparency of trachea, oesophagus, thymus and heart was achieved after ECi-based OTC. With anti-CD31 antibody immunofluorescence labelling before ECi-based OTC, the vasculature of these tissues with their natural morphology, location and organizational network was imaged using LSFM or LCFM. This simple protocol pipeline provides an easy-to-setup and comprehensive way to study the vasculature of mediastinal organs in 3D without any special equipment. We anticipate that it will facilitate diverse applications in biomedical research of thoracic diseases and even other organs. 
650 4 |a 3D imaging 
650 4 |a ethyl cinnamate 
650 4 |a mediastinal organs 
650 4 |a optical tissue clearing 
650 4 |a vasculature 
700 1 |a Picascia, Tiziana  |d 1993-  |e VerfasserIn  |0 (DE-588)1253880239  |0 (DE-627)1796243914  |4 aut 
700 1 |a Khan, Arif ul Maula  |d 1983-  |e VerfasserIn  |0 (DE-588)113663424X  |0 (DE-627)893342785  |0 (DE-576)490724361  |4 aut 
700 1 |a Heuveline, Vincent  |d 1968-  |e VerfasserIn  |0 (DE-588)1046579266  |0 (DE-627)776691880  |0 (DE-576)399904727  |4 aut 
700 1 |a Gretz, Norbert  |d 1954-2023  |e VerfasserIn  |0 (DE-588)1020104589  |0 (DE-627)691105154  |0 (DE-576)359544843  |4 aut 
773 0 8 |i Enthalten in  |t International journal of experimental pathology  |d Oxford [u.a.] : Wiley-Blackwell, 1990  |g 102(2021), 4/5, Seite 218-227  |h Online-Ressource  |w (DE-627)320482758  |w (DE-600)2010007-3  |w (DE-576)091143071  |x 1365-2613  |7 nnas  |a A simple optical tissue clearing pipeline for 3D vasculature imaging of the mediastinal organs in mice 
773 1 8 |g volume:102  |g year:2021  |g number:4/5  |g pages:218-227  |g extent:10  |a A simple optical tissue clearing pipeline for 3D vasculature imaging of the mediastinal organs in mice 
856 4 0 |u https://doi.org/10.1111/iep.12399  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/iep.12399  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20221128 
993 |a Article 
994 |a 2021 
998 |g 1020104589  |a Gretz, Norbert  |m 1020104589:Gretz, Norbert  |d 60000  |d 999811  |e 60000PG1020104589  |e 999811PG1020104589  |k 0/60000/  |k 1/60000/999811/  |p 5  |y j 
998 |g 1046579266  |a Heuveline, Vincent  |m 1046579266:Heuveline, Vincent  |d 700000  |d 708000  |e 700000PH1046579266  |e 708000PH1046579266  |k 0/700000/  |k 1/700000/708000/  |p 4 
998 |g 113663424X  |a Khan, Arif ul Maula  |m 113663424X:Khan, Arif ul Maula  |d 60000  |d 999811  |e 60000PK113663424X  |e 999811PK113663424X  |k 0/60000/  |k 1/60000/999811/  |p 3 
998 |g 1253880239  |a Picascia, Tiziana  |m 1253880239:Picascia, Tiziana  |d 60000  |e 60000PP1253880239  |k 0/60000/  |p 2 
998 |g 1246545772  |a Sun, Quanchao  |m 1246545772:Sun, Quanchao  |d 60000  |d 999811  |d 60000  |e 60000PS1246545772  |e 999811PS1246545772  |e 60000PS1246545772  |k 0/60000/  |k 1/60000/999811/  |k 0/60000/  |p 1  |x j 
999 |a KXP-PPN1823745423  |e 4221041862 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Quanchao Sun, Picascia Tiziana, Arif ul Maula Khan, Vincent Heuveline, Norbert Gretz"]},"language":["eng"],"note":["Gesehen am 28.11.2022"],"recId":"1823745423","person":[{"display":"Sun, Quanchao","given":"Quanchao","role":"aut","family":"Sun"},{"role":"aut","family":"Picascia","display":"Picascia, Tiziana","given":"Tiziana"},{"family":"Khan","role":"aut","display":"Khan, Arif ul Maula","given":"Arif ul Maula"},{"given":"Vincent","display":"Heuveline, Vincent","role":"aut","family":"Heuveline"},{"given":"Norbert","display":"Gretz, Norbert","family":"Gretz","role":"aut"}],"id":{"eki":["1823745423"],"doi":["10.1111/iep.12399"]},"physDesc":[{"extent":"10 S."}],"title":[{"title_sort":"simple optical tissue clearing pipeline for 3D vasculature imaging of the mediastinal organs in mice","title":"A simple optical tissue clearing pipeline for 3D vasculature imaging of the mediastinal organs in mice"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2021","dateIssuedDisp":"06 October 2021"}],"relHost":[{"id":{"doi":["10.1111/(ISSN)1365-2613"],"zdb":["2010007-3"],"eki":["320482758"],"issn":["1365-2613"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"International journal of experimental pathology","title_sort":"International journal of experimental pathology"}],"origin":[{"dateIssuedDisp":"1990-","publisher":"Wiley-Blackwell ; Blackwell Science ; Blackwell","publisherPlace":"Oxford [u.a.] ; Oxford [u.a.] ; Oxford [u.a.]","dateIssuedKey":"1990"}],"recId":"320482758","disp":"A simple optical tissue clearing pipeline for 3D vasculature imaging of the mediastinal organs in miceInternational journal of experimental pathology","type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"Journal of experimental pathology"}],"part":{"year":"2021","volume":"102","issue":"4/5","extent":"10","pages":"218-227","text":"102(2021), 4/5, Seite 218-227"},"language":["eng"],"pubHistory":["71.1990 -"],"note":["Gesehen am 05.12.11"]}]} 
SRT |a SUNQUANCHASIMPLEOPTI0620