Implementation and workflow for PET monitoring of therapeutic ion irradiation: a comparison of in-beam, in-room, and off-line techniques

An independent assessment of the dose delivery in ion therapy can be performed using positron emission tomography (PET). For that a distribution of positron emitters which appear as the result of interaction between ions of the therapeutic beam and the irradiated tissue is measured during or after t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Shakirin, Georgy (VerfasserIn) , Braess, Henning (VerfasserIn) , Fiedler, Fine (VerfasserIn) , Kunath, Daniela (VerfasserIn) , Laube, Kristin (VerfasserIn) , Parodi, Katia (VerfasserIn) , Priegnitz, Marlen (VerfasserIn) , Enghardt, Wolfgang (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 1 February 2011
In: Physics in medicine and biology
Year: 2011, Jahrgang: 56, Heft: 5, Pages: 1281-1298
ISSN:1361-6560
DOI:10.1088/0031-9155/56/5/004
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/0031-9155/56/5/004
Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1088/0031-9155/56/5/004
Volltext
Verfasserangaben:Georgy Shakirin, Henning Braess, Fine Fiedler, Daniela Kunath, Kristin Laube, Katia Parodi, Marlen Priegnitz and Wolfgang Enghardt

MARC

LEADER 00000caa a2200000 c 4500
001 1823991211
003 DE-627
005 20230710101257.0
007 cr uuu---uuuuu
008 221130s2011 xx |||||o 00| ||eng c
024 7 |a 10.1088/0031-9155/56/5/004  |2 doi 
035 |a (DE-627)1823991211 
035 |a (DE-599)KXP1823991211 
035 |a (OCoLC)1389744668 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Shakirin, Georgy  |d 1979-  |e VerfasserIn  |0 (DE-588)139371419  |0 (DE-627)610260693  |0 (DE-576)311317863  |4 aut 
245 1 0 |a Implementation and workflow for PET monitoring of therapeutic ion irradiation  |b a comparison of in-beam, in-room, and off-line techniques  |c Georgy Shakirin, Henning Braess, Fine Fiedler, Daniela Kunath, Kristin Laube, Katia Parodi, Marlen Priegnitz and Wolfgang Enghardt 
264 1 |c 1 February 2011 
300 |b Illustrationen 
300 |a 18 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.11.2022 
520 |a An independent assessment of the dose delivery in ion therapy can be performed using positron emission tomography (PET). For that a distribution of positron emitters which appear as the result of interaction between ions of the therapeutic beam and the irradiated tissue is measured during or after the irradiation. Three concepts for PET monitoring implemented in various therapy facilities are considered in this paper. The in-beam PET concept relies on the PET measurement performed simultaneously to the irradiation by means of a PET scanner which is completely integrated into the irradiation site. The in-room PET concept allows measurement immediately after irradiation by a standalone PET scanner which is installed very close to the irradiation site. In the off-line PET scenario the measurement is performed by means of a standalone PET/CT scanner 10-30 min after the irradiation. These three concepts were evaluated according to image quality criteria, integration costs, and their influence onto the workflow of radiotherapy. In-beam PET showed the best performance. However, the integration costs were estimated as very high for this modality. Moreover, the performance of in-beam PET depends heavily on type and duty cycle of the accelerator. The in-room PET is proposed for planned therapy facilities as a good compromise between the quality of measured data and integration efforts. For facilities which are close to the nuclear medicine departments off-line PET can be suggested under several circumstances. 
700 1 |a Braess, Henning  |e VerfasserIn  |4 aut 
700 1 |a Fiedler, Fine  |e VerfasserIn  |4 aut 
700 1 |a Kunath, Daniela  |e VerfasserIn  |4 aut 
700 1 |a Laube, Kristin  |e VerfasserIn  |4 aut 
700 1 |a Parodi, Katia  |d 1975-  |e VerfasserIn  |0 (DE-588)129736996  |0 (DE-627)707308917  |0 (DE-576)188641688  |4 aut 
700 1 |a Priegnitz, Marlen  |e VerfasserIn  |4 aut 
700 1 |a Enghardt, Wolfgang  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 56(2011), 5 vom: Feb., Seite 1281-1298  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Implementation and workflow for PET monitoring of therapeutic ion irradiation a comparison of in-beam, in-room, and off-line techniques 
773 1 8 |g volume:56  |g year:2011  |g number:5  |g month:02  |g pages:1281-1298  |g extent:18  |a Implementation and workflow for PET monitoring of therapeutic ion irradiation a comparison of in-beam, in-room, and off-line techniques 
856 4 0 |u https://doi.org/10.1088/0031-9155/56/5/004  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/0031-9155/56/5/004  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20221130 
993 |a Article 
994 |a 2011 
998 |g 129736996  |a Parodi, Katia  |m 129736996:Parodi, Katia  |d 910000  |d 950000  |d 950400  |e 910000PP129736996  |e 950000PP129736996  |e 950400PP129736996  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 6 
999 |a KXP-PPN1823991211  |e 4222084735 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1088/0031-9155/56/5/004"],"eki":["1823991211"]},"origin":[{"dateIssuedKey":"2011","dateIssuedDisp":"1 February 2011"}],"name":{"displayForm":["Georgy Shakirin, Henning Braess, Fine Fiedler, Daniela Kunath, Kristin Laube, Katia Parodi, Marlen Priegnitz and Wolfgang Enghardt"]},"relHost":[{"pubHistory":["1.1956 -"],"part":{"text":"56(2011), 5 vom: Feb., Seite 1281-1298","volume":"56","extent":"18","year":"2011","pages":"1281-1298","issue":"5"},"disp":"Implementation and workflow for PET monitoring of therapeutic ion irradiation a comparison of in-beam, in-room, and off-line techniquesPhysics in medicine and biology","note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"recId":"269016163","title":[{"title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"IOP Publ.","dateIssuedKey":"1956","dateIssuedDisp":"1956-","publisherPlace":"Bristol"}],"id":{"zdb":["1473501-5"],"eki":["269016163"],"issn":["1361-6560"]}}],"physDesc":[{"extent":"18 S.","noteIll":"Illustrationen"}],"title":[{"subtitle":"a comparison of in-beam, in-room, and off-line techniques","title":"Implementation and workflow for PET monitoring of therapeutic ion irradiation","title_sort":"Implementation and workflow for PET monitoring of therapeutic ion irradiation"}],"person":[{"role":"aut","display":"Shakirin, Georgy","roleDisplay":"VerfasserIn","given":"Georgy","family":"Shakirin"},{"role":"aut","display":"Braess, Henning","roleDisplay":"VerfasserIn","given":"Henning","family":"Braess"},{"roleDisplay":"VerfasserIn","display":"Fiedler, Fine","role":"aut","family":"Fiedler","given":"Fine"},{"roleDisplay":"VerfasserIn","display":"Kunath, Daniela","role":"aut","family":"Kunath","given":"Daniela"},{"given":"Kristin","family":"Laube","role":"aut","roleDisplay":"VerfasserIn","display":"Laube, Kristin"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Parodi, Katia","given":"Katia","family":"Parodi"},{"family":"Priegnitz","given":"Marlen","display":"Priegnitz, Marlen","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Wolfgang","family":"Enghardt","role":"aut","display":"Enghardt, Wolfgang","roleDisplay":"VerfasserIn"}],"language":["eng"],"recId":"1823991211","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 30.11.2022"]} 
SRT |a SHAKIRINGEIMPLEMENTA1201