Integration of maXs-type microcalorimeter detectors for high-resolution x-ray spectroscopy into the experimental environment at the CRYRINGESR electron cooler

We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI 6 , Darmstadt, namely at the electron cooler of CRYRINGESR. Two of these...

Full description

Saved in:
Bibliographic Details
Main Authors: Pfäfflein, Philip (Author) , Allgeier, Steffen (Author) , Bernitt, Sonja (Author) , Fleischmann, Andreas (Author) , Friedrich, M. (Author) , Hahn, Christoph (Author) , Hengstler, Daniel (Author) , Herdrich, Marc Oliver (Author) , Kalinin, A. (Author) , Kröger, Felix Martin (Author) , Kuntz, P. (Author) , Lestinsky, Michael (Author) , Löher, B. (Author) , Menz, E. B. (Author) , Over, Tobias (Author) , Spillmann, Uwe (Author) , Weber, Günter (Author) , Zhu, Binghui (Author) , Enss, Christian (Author) , Stöhlker, Thomas (Author)
Format: Article (Journal)
Language:English
Published: 14 October 2022
In: Physica scripta
Year: 2022, Volume: 97, Issue: 11, Pages: 1-14
ISSN:1402-4896
DOI:10.1088/1402-4896/ac93be
Online Access:Resolving-System, lizenzpflichtig, Volltext: https://doi.org/10.1088/1402-4896/ac93be
Verlag, lizenzpflichtig, Volltext: https://iopscience.iop.org/article/10.1088/1402-4896/ac93be
Get full text
Author Notes:Ph Pfäfflein, S Allgeier, S Bernitt, A Fleischmann, M Friedrich, Ch Hahn, D Hengstler, M.O Herdrich, A Kalinin, F.M Kröger, P Kuntz, M Lestinsky, B Löher, E.B Menz, T Over, U Spillmann, G Weber, B Zhu, Ch Enss and Th Stöhlker
Description
Summary:We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI 6 , Darmstadt, namely at the electron cooler of CRYRINGESR. Two of these detector systems were positioned at the 0° and 180° view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors’ time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.
Item Description:Gesehen am 06.12.2022
Physical Description:Online Resource
ISSN:1402-4896
DOI:10.1088/1402-4896/ac93be