Automatic quantitative assessment of lens opacities using two anterior segment imaging techniques: correlation with functional and surgical metrics
The purpose of this study is to quantitatively assess lens opacity, using a swept-source optical coherence tomography (SS-OCT) device for anterior segment assessment, and establish the correlation with Scheimpflug imaging, corrected distance visual acuity (CDVA) and cumulative dissipated energy (CDE...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
4 October 2022
|
| In: |
Diagnostics
Year: 2022, Jahrgang: 12, Heft: 10, Pages: 1-13 |
| ISSN: | 2075-4418 |
| DOI: | 10.3390/diagnostics12102406 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.3390/diagnostics12102406 Verlag, lizenzpflichtig, Volltext: https://www.mdpi.com/2075-4418/12/10/2406 |
| Verfasserangaben: | Lars H. B. Mackenbrock, Grzegorz Łabuz, Timur M. Yildirim, Gerd U. Auffarth and Ramin Khoramnia |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1826738746 | ||
| 003 | DE-627 | ||
| 005 | 20230118120620.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 221209s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.3390/diagnostics12102406 |2 doi | |
| 035 | |a (DE-627)1826738746 | ||
| 035 | |a (DE-599)KXP1826738746 | ||
| 035 | |a (OCoLC)1361670326 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Mackenbrock, Lars |e VerfasserIn |0 (DE-588)1275175031 |0 (DE-627)1826739165 |4 aut | |
| 245 | 1 | 0 | |a Automatic quantitative assessment of lens opacities using two anterior segment imaging techniques |b correlation with functional and surgical metrics |c Lars H. B. Mackenbrock, Grzegorz Łabuz, Timur M. Yildirim, Gerd U. Auffarth and Ramin Khoramnia |
| 264 | 1 | |c 4 October 2022 | |
| 300 | |a 13 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 09.12.2022 | ||
| 520 | |a The purpose of this study is to quantitatively assess lens opacity, using a swept-source optical coherence tomography (SS-OCT) device for anterior segment assessment, and establish the correlation with Scheimpflug imaging, corrected distance visual acuity (CDVA) and cumulative dissipated energy (CDE). This prospective cross-sectional single-center study enrolled 51 patients (51 eyes) with crystalline lens opacity. Patients with previous ocular surgery, pathologies or general disorders affecting vision were excluded. Eyes were scanned with an SS-OCT device, and lens densitometry was automatically analyzed using a custom MATLAB script which examined lens density, nuclear density and linear density. The same analyses were performed on Scheimpflug images. Preoperative CDVA and CDE during phacoemulsification were recorded. Spearman’s (ρ) and Pearson’s (r) correlation coefficients were assessed according to data normality. Statistically significant correlations were established between SS-OCT and Scheimpflug imaging using lens analysis (ρ = 0.47, p < 0.001), nuclear analysis (ρ = 0.73, p < 0.001) and linear analysis (r = 0.44, p < 0.001). A significant correlation with CDE was found with all the SS-OCT methods (r = 0.57, p < 0.001). Only the nuclear analysis of the SS-OCT scans (Tb = −0.33, p < 0.01) and Pentacam Nucleus Staging (Tb = −0.26, p < 0.05) showed a statistically significant correlation with CDVA. Good inter-device agreement in lens densitometry was found. However, SS-OCT yielded improved lens imaging compared with the Scheimpflug device and a higher correlation with clinical parameters. Thus, high-resolution SS-OCT has the potential to become a preferable option for automatic cataract grading and preoperative planning. | ||
| 650 | 4 | |a anterior segment OCT | |
| 650 | 4 | |a cataract | |
| 650 | 4 | |a Scheimpflug imaging | |
| 700 | 1 | |a Łabuz, Grzegorz |e VerfasserIn |0 (DE-588)1185406743 |0 (DE-627)1664595244 |4 aut | |
| 700 | 1 | |a Yildirim, Timur Mert |d 1990- |e VerfasserIn |0 (DE-588)112972557X |0 (DE-627)88437422X |0 (DE-576)486529894 |4 aut | |
| 700 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 700 | 1 | |a Khoramnia, Ramin |d 1980- |e VerfasserIn |0 (DE-588)132573954 |0 (DE-627)523957173 |0 (DE-576)299234355 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Diagnostics |d Basel : MDPI, 2011 |g 12(2022), 10, Artikel-ID 2406, Seite 1-13 |h Online-Ressource |w (DE-627)718627814 |w (DE-600)2662336-5 |w (DE-576)365413917 |x 2075-4418 |7 nnas |a Automatic quantitative assessment of lens opacities using two anterior segment imaging techniques correlation with functional and surgical metrics |
| 773 | 1 | 8 | |g volume:12 |g year:2022 |g number:10 |g elocationid:2406 |g pages:1-13 |g extent:13 |a Automatic quantitative assessment of lens opacities using two anterior segment imaging techniques correlation with functional and surgical metrics |
| 856 | 4 | 0 | |u https://doi.org/10.3390/diagnostics12102406 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.mdpi.com/2075-4418/12/10/2406 |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20221209 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 132573954 |a Khoramnia, Ramin |m 132573954:Khoramnia, Ramin |d 910000 |d 910900 |e 910000PK132573954 |e 910900PK132573954 |k 0/910000/ |k 1/910000/910900/ |p 5 |y j | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 4 | ||
| 998 | |g 112972557X |a Yildirim, Timur Mert |m 112972557X:Yildirim, Timur Mert |d 910000 |d 910900 |e 910000PY112972557X |e 910900PY112972557X |k 0/910000/ |k 1/910000/910900/ |p 3 | ||
| 998 | |g 1185406743 |a Łabuz, Grzegorz |m 1185406743:Łabuz, Grzegorz |d 910000 |d 910900 |e 910000PŁ1185406743 |e 910900PŁ1185406743 |k 0/910000/ |k 1/910000/910900/ |p 2 | ||
| 998 | |g 1275175031 |a Mackenbrock, Lars |m 1275175031:Mackenbrock, Lars |p 1 |x j | ||
| 999 | |a KXP-PPN1826738746 |e 422880182X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"name":{"displayForm":["Lars H. B. Mackenbrock, Grzegorz Łabuz, Timur M. Yildirim, Gerd U. Auffarth and Ramin Khoramnia"]},"title":[{"subtitle":"correlation with functional and surgical metrics","title":"Automatic quantitative assessment of lens opacities using two anterior segment imaging techniques","title_sort":"Automatic quantitative assessment of lens opacities using two anterior segment imaging techniques"}],"origin":[{"dateIssuedKey":"2022","dateIssuedDisp":"4 October 2022"}],"person":[{"given":"Lars","family":"Mackenbrock","display":"Mackenbrock, Lars","role":"aut"},{"role":"aut","display":"Łabuz, Grzegorz","family":"Łabuz","given":"Grzegorz"},{"given":"Timur Mert","role":"aut","display":"Yildirim, Timur Mert","family":"Yildirim"},{"role":"aut","display":"Auffarth, Gerd U.","family":"Auffarth","given":"Gerd U."},{"family":"Khoramnia","role":"aut","display":"Khoramnia, Ramin","given":"Ramin"}],"id":{"eki":["1826738746"],"doi":["10.3390/diagnostics12102406"]},"note":["Gesehen am 09.12.2022"],"language":["eng"],"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 28.05.2020"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"718627814","disp":"Automatic quantitative assessment of lens opacities using two anterior segment imaging techniques correlation with functional and surgical metricsDiagnostics","title":[{"title_sort":"Diagnostics","title":"Diagnostics","subtitle":"open access journal"}],"origin":[{"dateIssuedKey":"2011","publisherPlace":"Basel","publisher":"MDPI","dateIssuedDisp":"2011-"}],"id":{"zdb":["2662336-5"],"eki":["718627814"],"issn":["2075-4418"]},"part":{"volume":"12","extent":"13","issue":"10","pages":"1-13","text":"12(2022), 10, Artikel-ID 2406, Seite 1-13","year":"2022"},"pubHistory":["1.2011 -"],"language":["eng"]}],"physDesc":[{"extent":"13 S."}],"recId":"1826738746"} | ||
| SRT | |a MACKENBROCAUTOMATICQ4202 | ||