In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla
Purpose: This in-vitro study aimed to compare the accuracy of complete arch scans (CAS) of a fully dentate (FD) and a partially edentulous (PE) maxillary model. Three intraoral scanning systems were used: Omnicam AC (OC), TRIOS 4 (TR), and Primescan (PS). - Methods: Each intraoral scanner was used t...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2022
|
| In: |
Journal of prosthodontic research
Year: 2022, Jahrgang: 66, Heft: 4, Pages: 538-545 |
| ISSN: | 1883-1958 |
| DOI: | 10.2186/jpr.JPR_D_21_00100 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.2186/jpr.JPR_D_21_00100 Verlag, lizenzpflichtig, Volltext: https://www.jstage.jst.go.jp/article/jpr/66/4/66_JPR_D_21_00100/_article |
| Verfasserangaben: | Moritz Waldecker, Wolfgang Bömicke, Rouven Behnisch, Peter Rammelsberg, Stefan Rues |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1834611105 | ||
| 003 | DE-627 | ||
| 005 | 20230706233555.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 230213s2022 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.2186/jpr.JPR_D_21_00100 |2 doi | |
| 035 | |a (DE-627)1834611105 | ||
| 035 | |a (DE-599)KXP1834611105 | ||
| 035 | |a (OCoLC)1389535635 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Waldecker, Moritz |d 1986- |e VerfasserIn |0 (DE-588)114780172X |0 (DE-627)1007199024 |0 (DE-576)496051652 |4 aut | |
| 245 | 1 | 0 | |a In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla |c Moritz Waldecker, Wolfgang Bömicke, Rouven Behnisch, Peter Rammelsberg, Stefan Rues |
| 264 | 1 | |c 2022 | |
| 300 | |b Illustrationen | ||
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 13.02.2023 | ||
| 500 | |a Online publiziert: 7 December 2021 | ||
| 520 | |a Purpose: This in-vitro study aimed to compare the accuracy of complete arch scans (CAS) of a fully dentate (FD) and a partially edentulous (PE) maxillary model. Three intraoral scanning systems were used: Omnicam AC (OC), TRIOS 4 (TR), and Primescan (PS). - Methods: Each intraoral scanner was used to take 30 scans each of two clinical scenarios (FD and PE) simulated by a reference model. The PE model simulated a maxilla with six prepared teeth to accommodate a jaw-spanning fixed partial denture (FPD). The missing teeth were then added to create an FD model. Five ceramic precision balls (ball centers P1-P5) mounted on metal pins were welded to the metal base on the buccal side of the dental arch. These were later used to determine dimensional (given by each 2 ball centers) and angular changes (given by each 3 or 4 ball centers) between the reference model (digitized with high precision before the tests) and the intraoral scans. Data were statistically analyzed using a type II ANOVA. - Results: The maximum mean absolute distance deviations were as follows. OC: 147 µm (FD) and 139 µm (PE). TR: 133 µm (FD) and 136 µm (PE). PS: 87 µm (FD) and 80 µm (PE). The scanning system used had a significant effect on distance deviations (p < 0.027) and CAS scanning time (p < 0.001). Dental status had no clear effect on distance deviations but did significantly affect angular changes (p < 0.001) and scanning time (p < 0.001). - Conclusion: The manufacture of jaw-spanning FPDs based on a CAS cannot yet be recommended. | ||
| 700 | 1 | |a Bömicke, Wolfgang |d 1981- |e VerfasserIn |0 (DE-588)1015022146 |0 (DE-627)668338792 |0 (DE-576)349947651 |4 aut | |
| 700 | 1 | |a Behnisch, Rouven |d 1990- |e VerfasserIn |0 (DE-588)1191206238 |0 (DE-627)1669619265 |4 aut | |
| 700 | 1 | |a Rammelsberg, Peter |d 1959- |e VerfasserIn |0 (DE-588)122469836 |0 (DE-627)705920836 |0 (DE-576)293285640 |4 aut | |
| 700 | 1 | |a Rues, Stefan |e VerfasserIn |0 (DE-588)1054444927 |0 (DE-627)792098331 |0 (DE-576)410292168 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of prosthodontic research |d Amstedam [u.a.] : Elsevier, 2009 |g 66(2022), 4, Seite 538-545 |h Online-Ressource |w (DE-627)587142073 |w (DE-600)2467982-3 |w (DE-576)301539243 |x 1883-1958 |7 nnas |a In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla |
| 773 | 1 | 8 | |g volume:66 |g year:2022 |g number:4 |g pages:538-545 |g extent:8 |a In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla |
| 856 | 4 | 0 | |u https://doi.org/10.2186/jpr.JPR_D_21_00100 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://www.jstage.jst.go.jp/article/jpr/66/4/66_JPR_D_21_00100/_article |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20230213 | ||
| 993 | |a Article | ||
| 994 | |a 2022 | ||
| 998 | |g 1054444927 |a Rues, Stefan |m 1054444927:Rues, Stefan |d 910000 |d 910800 |e 910000PR1054444927 |e 910800PR1054444927 |k 0/910000/ |k 1/910000/910800/ |p 5 |y j | ||
| 998 | |g 122469836 |a Rammelsberg, Peter |m 122469836:Rammelsberg, Peter |d 910000 |d 910800 |e 910000PR122469836 |e 910800PR122469836 |k 0/910000/ |k 1/910000/910800/ |p 4 | ||
| 998 | |g 1191206238 |a Behnisch, Rouven |m 1191206238:Behnisch, Rouven |d 910000 |d 911800 |e 910000PB1191206238 |e 911800PB1191206238 |k 0/910000/ |k 1/910000/911800/ |p 3 | ||
| 998 | |g 1015022146 |a Bömicke, Wolfgang |m 1015022146:Bömicke, Wolfgang |d 910000 |d 910800 |d 50000 |e 910000PB1015022146 |e 910800PB1015022146 |e 50000PB1015022146 |k 0/910000/ |k 1/910000/910800/ |k 0/50000/ |p 2 | ||
| 998 | |g 114780172X |a Waldecker, Moritz |m 114780172X:Waldecker, Moritz |d 910000 |d 910800 |e 910000PW114780172X |e 910800PW114780172X |k 0/910000/ |k 1/910000/910800/ |p 1 |x j | ||
| 999 | |a KXP-PPN1834611105 |e 4271198706 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"noteIll":"Illustrationen","extent":"8 S."}],"person":[{"given":"Moritz","family":"Waldecker","display":"Waldecker, Moritz","role":"aut"},{"display":"Bömicke, Wolfgang","family":"Bömicke","given":"Wolfgang","role":"aut"},{"role":"aut","display":"Behnisch, Rouven","family":"Behnisch","given":"Rouven"},{"given":"Peter","family":"Rammelsberg","display":"Rammelsberg, Peter","role":"aut"},{"role":"aut","given":"Stefan","display":"Rues, Stefan","family":"Rues"}],"title":[{"title_sort":"In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla","title":"In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla"}],"relHost":[{"id":{"eki":["587142073"],"issn":["1883-1958"],"zdb":["2467982-3"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"corporate":[{"display":"Nihon-Hōtetsu-Shika-Gakkai","role":"isb"}],"language":["eng"],"name":{"displayForm":["Japan Prosthodontic Society"]},"pubHistory":["53.2009 -"],"recId":"587142073","note":["Gesehen am 01.02.2024"],"disp":"In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxillaJournal of prosthodontic research","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Journal of prosthodontic research","title":"Journal of prosthodontic research"}],"part":{"pages":"538-545","text":"66(2022), 4, Seite 538-545","volume":"66","issue":"4","year":"2022","extent":"8"},"origin":[{"publisher":"Elsevier","dateIssuedKey":"2009","dateIssuedDisp":"2009-","publisherPlace":"Amstedam [u.a.]"}]}],"origin":[{"dateIssuedDisp":"2022","dateIssuedKey":"2022"}],"id":{"doi":["10.2186/jpr.JPR_D_21_00100"],"eki":["1834611105"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"name":{"displayForm":["Moritz Waldecker, Wolfgang Bömicke, Rouven Behnisch, Peter Rammelsberg, Stefan Rues"]},"recId":"1834611105","note":["Gesehen am 13.02.2023","Online publiziert: 7 December 2021"]} | ||
| SRT | |a WALDECKERMINVITROACC2022 | ||