In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla

Purpose: This in-vitro study aimed to compare the accuracy of complete arch scans (CAS) of a fully dentate (FD) and a partially edentulous (PE) maxillary model. Three intraoral scanning systems were used: Omnicam AC (OC), TRIOS 4 (TR), and Primescan (PS). - Methods: Each intraoral scanner was used t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Waldecker, Moritz (VerfasserIn) , Bömicke, Wolfgang (VerfasserIn) , Behnisch, Rouven (VerfasserIn) , Rammelsberg, Peter (VerfasserIn) , Rues, Stefan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2022
In: Journal of prosthodontic research
Year: 2022, Jahrgang: 66, Heft: 4, Pages: 538-545
ISSN:1883-1958
DOI:10.2186/jpr.JPR_D_21_00100
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.2186/jpr.JPR_D_21_00100
Verlag, lizenzpflichtig, Volltext: https://www.jstage.jst.go.jp/article/jpr/66/4/66_JPR_D_21_00100/_article
Volltext
Verfasserangaben:Moritz Waldecker, Wolfgang Bömicke, Rouven Behnisch, Peter Rammelsberg, Stefan Rues

MARC

LEADER 00000caa a2200000 c 4500
001 1834611105
003 DE-627
005 20230706233555.0
007 cr uuu---uuuuu
008 230213s2022 xx |||||o 00| ||eng c
024 7 |a 10.2186/jpr.JPR_D_21_00100  |2 doi 
035 |a (DE-627)1834611105 
035 |a (DE-599)KXP1834611105 
035 |a (OCoLC)1389535635 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Waldecker, Moritz  |d 1986-  |e VerfasserIn  |0 (DE-588)114780172X  |0 (DE-627)1007199024  |0 (DE-576)496051652  |4 aut 
245 1 0 |a In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla  |c Moritz Waldecker, Wolfgang Bömicke, Rouven Behnisch, Peter Rammelsberg, Stefan Rues 
264 1 |c 2022 
300 |b Illustrationen 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 13.02.2023 
500 |a Online publiziert: 7 December 2021 
520 |a Purpose: This in-vitro study aimed to compare the accuracy of complete arch scans (CAS) of a fully dentate (FD) and a partially edentulous (PE) maxillary model. Three intraoral scanning systems were used: Omnicam AC (OC), TRIOS 4 (TR), and Primescan (PS). - Methods: Each intraoral scanner was used to take 30 scans each of two clinical scenarios (FD and PE) simulated by a reference model. The PE model simulated a maxilla with six prepared teeth to accommodate a jaw-spanning fixed partial denture (FPD). The missing teeth were then added to create an FD model. Five ceramic precision balls (ball centers P1-P5) mounted on metal pins were welded to the metal base on the buccal side of the dental arch. These were later used to determine dimensional (given by each 2 ball centers) and angular changes (given by each 3 or 4 ball centers) between the reference model (digitized with high precision before the tests) and the intraoral scans. Data were statistically analyzed using a type II ANOVA. - Results: The maximum mean absolute distance deviations were as follows. OC: 147 µm (FD) and 139 µm (PE). TR: 133 µm (FD) and 136 µm (PE). PS: 87 µm (FD) and 80 µm (PE). The scanning system used had a significant effect on distance deviations (p < 0.027) and CAS scanning time (p < 0.001). Dental status had no clear effect on distance deviations but did significantly affect angular changes (p < 0.001) and scanning time (p < 0.001). - Conclusion: The manufacture of jaw-spanning FPDs based on a CAS cannot yet be recommended. 
700 1 |a Bömicke, Wolfgang  |d 1981-  |e VerfasserIn  |0 (DE-588)1015022146  |0 (DE-627)668338792  |0 (DE-576)349947651  |4 aut 
700 1 |a Behnisch, Rouven  |d 1990-  |e VerfasserIn  |0 (DE-588)1191206238  |0 (DE-627)1669619265  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
700 1 |a Rues, Stefan  |e VerfasserIn  |0 (DE-588)1054444927  |0 (DE-627)792098331  |0 (DE-576)410292168  |4 aut 
773 0 8 |i Enthalten in  |t Journal of prosthodontic research  |d Amstedam [u.a.] : Elsevier, 2009  |g 66(2022), 4, Seite 538-545  |h Online-Ressource  |w (DE-627)587142073  |w (DE-600)2467982-3  |w (DE-576)301539243  |x 1883-1958  |7 nnas  |a In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla 
773 1 8 |g volume:66  |g year:2022  |g number:4  |g pages:538-545  |g extent:8  |a In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla 
856 4 0 |u https://doi.org/10.2186/jpr.JPR_D_21_00100  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.jstage.jst.go.jp/article/jpr/66/4/66_JPR_D_21_00100/_article  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230213 
993 |a Article 
994 |a 2022 
998 |g 1054444927  |a Rues, Stefan  |m 1054444927:Rues, Stefan  |d 910000  |d 910800  |e 910000PR1054444927  |e 910800PR1054444927  |k 0/910000/  |k 1/910000/910800/  |p 5  |y j 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 1191206238  |a Behnisch, Rouven  |m 1191206238:Behnisch, Rouven  |d 910000  |d 911800  |e 910000PB1191206238  |e 911800PB1191206238  |k 0/910000/  |k 1/910000/911800/  |p 3 
998 |g 1015022146  |a Bömicke, Wolfgang  |m 1015022146:Bömicke, Wolfgang  |d 910000  |d 910800  |d 50000  |e 910000PB1015022146  |e 910800PB1015022146  |e 50000PB1015022146  |k 0/910000/  |k 1/910000/910800/  |k 0/50000/  |p 2 
998 |g 114780172X  |a Waldecker, Moritz  |m 114780172X:Waldecker, Moritz  |d 910000  |d 910800  |e 910000PW114780172X  |e 910800PW114780172X  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1834611105  |e 4271198706 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"noteIll":"Illustrationen","extent":"8 S."}],"person":[{"given":"Moritz","family":"Waldecker","display":"Waldecker, Moritz","role":"aut"},{"display":"Bömicke, Wolfgang","family":"Bömicke","given":"Wolfgang","role":"aut"},{"role":"aut","display":"Behnisch, Rouven","family":"Behnisch","given":"Rouven"},{"given":"Peter","family":"Rammelsberg","display":"Rammelsberg, Peter","role":"aut"},{"role":"aut","given":"Stefan","display":"Rues, Stefan","family":"Rues"}],"title":[{"title_sort":"In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla","title":"In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxilla"}],"relHost":[{"id":{"eki":["587142073"],"issn":["1883-1958"],"zdb":["2467982-3"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"corporate":[{"display":"Nihon-Hōtetsu-Shika-Gakkai","role":"isb"}],"language":["eng"],"name":{"displayForm":["Japan Prosthodontic Society"]},"pubHistory":["53.2009 -"],"recId":"587142073","note":["Gesehen am 01.02.2024"],"disp":"In-vitro accuracy of complete arch scans of the fully dentate and the partially edentulous maxillaJournal of prosthodontic research","physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Journal of prosthodontic research","title":"Journal of prosthodontic research"}],"part":{"pages":"538-545","text":"66(2022), 4, Seite 538-545","volume":"66","issue":"4","year":"2022","extent":"8"},"origin":[{"publisher":"Elsevier","dateIssuedKey":"2009","dateIssuedDisp":"2009-","publisherPlace":"Amstedam [u.a.]"}]}],"origin":[{"dateIssuedDisp":"2022","dateIssuedKey":"2022"}],"id":{"doi":["10.2186/jpr.JPR_D_21_00100"],"eki":["1834611105"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"name":{"displayForm":["Moritz Waldecker, Wolfgang Bömicke, Rouven Behnisch, Peter Rammelsberg, Stefan Rues"]},"recId":"1834611105","note":["Gesehen am 13.02.2023","Online publiziert: 7 December 2021"]} 
SRT |a WALDECKERMINVITROACC2022