Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities

Objective. Reliable radionuclide production yield data are a prerequisite for positron-emission-tomography (PET) based in vivo proton treatment verification. In this context, activation data acquired at two different treatment facilities with different imaging systems were analyzed to provide experi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bauer, Julia (VerfasserIn) , Hildebrandt, Meret (VerfasserIn) , Baumgartl, Michael (VerfasserIn) , Fiedler, Fine (VerfasserIn) , Robert, Charlotte (VerfasserIn) , Buvat, Irène (VerfasserIn) , Enghardt, Wolfgang (VerfasserIn) , Parodi, Katia (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 14 July 2022
In: Physics in medicine and biology
Year: 2022, Jahrgang: 67, Heft: 15, Pages: 1-16
ISSN:1361-6560
DOI:10.1088/1361-6560/ac7a89
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1088/1361-6560/ac7a89
Verlag, lizenzpflichtig, Volltext: https://dx.doi.org/10.1088/1361-6560/ac7a89
Volltext
Verfasserangaben:Julia Bauer, Meret Hildebrandt, Michael Baumgartl, Fine Fiedler, Charlotte Robert, Irène Buvat, Wolfgang Enghardt and Katia Parodi

MARC

LEADER 00000caa a2200000 c 4500
001 1837577390
003 DE-627
005 20230706231827.0
007 cr uuu---uuuuu
008 230227s2022 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/ac7a89  |2 doi 
035 |a (DE-627)1837577390 
035 |a (DE-599)KXP1837577390 
035 |a (OCoLC)1389535420 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bauer, Julia  |e VerfasserIn  |0 (DE-588)107489099X  |0 (DE-627)832650145  |0 (DE-576)443090904  |4 aut 
245 1 0 |a Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities  |c Julia Bauer, Meret Hildebrandt, Michael Baumgartl, Fine Fiedler, Charlotte Robert, Irène Buvat, Wolfgang Enghardt and Katia Parodi 
264 1 |c 14 July 2022 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 27.02.2023 
520 |a Objective. Reliable radionuclide production yield data are a prerequisite for positron-emission-tomography (PET) based in vivo proton treatment verification. In this context, activation data acquired at two different treatment facilities with different imaging systems were analyzed to provide experimentally determined radionuclide yields in thick targets and were compared with each other to investigate the impact of the respective imaging technique. Approach. Homogeneous thick targets (PMMA, gelatine, and graphite) were irradiated with mono-energetic proton pencil-beams at two distinct energies. Material activation was measured (i) in-beam during and after beam delivery with a double-head prototype PET camera and (ii) offline shortly after beam delivery with a commercial full-ring PET/CT scanner. Integral as well as depth-resolved β +-emitter yields were determined for the dominant positron-emitting radionuclides 11C, 15O, 13N and (in-beam only) 10C. In-beam data were used to investigate the qualitative impact of different monitoring time schemes on activity depth profiles and their quantitative impact on count rates and total activity. Main results. Production yields measured with the in-beam camera were comparable to or higher compared to respective offline results. Depth profiles of radionuclide-specific yields obtained from the double-head camera showed qualitative differences to data acquired with the full-ring camera with a more convex profile shape. Considerable impact of the imaging timing scheme on the activity profile was observed for gelatine only with a range variation of up to 3.5 mm. Evaluation of the coincidence rate and the total number of observed events in the considered workflows confirmed a strongly decreasing rate in targets with a large oxygen fraction. Significance. The observed quantitative and qualitative differences between the datasets underline the importance of a thorough system commissioning. Due to the lack of reliable cross-section data, in-house phantom measurements are still considered a gold standard for careful characterization of the system response and to ensure a reliable beam range verification. 
700 1 |a Hildebrandt, Meret  |e VerfasserIn  |0 (DE-588)1072831147  |0 (DE-627)828394598  |0 (DE-576)434274895  |4 aut 
700 1 |a Baumgartl, Michael  |e VerfasserIn  |4 aut 
700 1 |a Fiedler, Fine  |e VerfasserIn  |4 aut 
700 1 |a Robert, Charlotte  |e VerfasserIn  |4 aut 
700 1 |a Buvat, Irène  |e VerfasserIn  |4 aut 
700 1 |a Enghardt, Wolfgang  |e VerfasserIn  |4 aut 
700 1 |a Parodi, Katia  |d 1975-  |e VerfasserIn  |0 (DE-588)129736996  |0 (DE-627)707308917  |0 (DE-576)188641688  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 67(2022), 15 vom: Juli, Artikel-ID 155001, Seite 1-16  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities 
773 1 8 |g volume:67  |g year:2022  |g number:15  |g month:07  |g elocationid:155001  |g pages:1-16  |g extent:16  |a Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities 
856 4 0 |u https://doi.org/10.1088/1361-6560/ac7a89  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://dx.doi.org/10.1088/1361-6560/ac7a89  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230227 
993 |a Article 
994 |a 2022 
998 |g 129736996  |a Parodi, Katia  |m 129736996:Parodi, Katia  |p 8  |y j 
998 |g 1072831147  |a Hildebrandt, Meret  |m 1072831147:Hildebrandt, Meret  |p 2 
998 |g 107489099X  |a Bauer, Julia  |m 107489099X:Bauer, Julia  |d 910000  |d 911400  |e 910000PB107489099X  |e 911400PB107489099X  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1837577390  |e 4277185150 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Julia","role":"aut","family":"Bauer","display":"Bauer, Julia"},{"display":"Hildebrandt, Meret","family":"Hildebrandt","given":"Meret","role":"aut"},{"role":"aut","given":"Michael","display":"Baumgartl, Michael","family":"Baumgartl"},{"display":"Fiedler, Fine","family":"Fiedler","role":"aut","given":"Fine"},{"role":"aut","given":"Charlotte","family":"Robert","display":"Robert, Charlotte"},{"role":"aut","given":"Irène","family":"Buvat","display":"Buvat, Irène"},{"display":"Enghardt, Wolfgang","family":"Enghardt","given":"Wolfgang","role":"aut"},{"display":"Parodi, Katia","family":"Parodi","given":"Katia","role":"aut"}],"note":["Gesehen am 27.02.2023"],"origin":[{"dateIssuedDisp":"14 July 2022","dateIssuedKey":"2022"}],"title":[{"title":"Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities","title_sort":"Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"physDesc":[{"extent":"16 S."}],"name":{"displayForm":["Julia Bauer, Meret Hildebrandt, Michael Baumgartl, Fine Fiedler, Charlotte Robert, Irène Buvat, Wolfgang Enghardt and Katia Parodi"]},"recId":"1837577390","id":{"doi":["10.1088/1361-6560/ac7a89"],"eki":["1837577390"]},"relHost":[{"id":{"zdb":["1473501-5"],"issn":["1361-6560"],"eki":["269016163"]},"recId":"269016163","pubHistory":["1.1956 -"],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"part":{"issue":"15","extent":"16","volume":"67","year":"2022","text":"67(2022), 15 vom: Juli, Artikel-ID 155001, Seite 1-16","pages":"1-16"},"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology"}],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"origin":[{"publisher":"IOP Publ.","dateIssuedKey":"1956","dateIssuedDisp":"1956-","publisherPlace":"Bristol"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilitiesPhysics in medicine and biology"}]} 
SRT |a BAUERJULIAQUANTITATI1420