Determination of low wear rates in metal-on-metal hip joint replacements based on ultra trace element analysis in simulator studies

Metal-on-metal joint bearings are being increasingly used for total hip arthroplasty. Previous results from simulator tests to determine wear of metal-on-metal bearings exhibited high fluctuations. Consequently, wear tests had to be performed for a long period of time to achieve stable values. The a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kretzer, Jan Philippe (VerfasserIn) , Krachler, Michael (VerfasserIn) , Reinders, Jörn (VerfasserIn) , Jakubowitz, Eike (VerfasserIn) , Thomsen, Marc N. (VerfasserIn) , Heisel, Jens Christian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2010
In: Tribology letters
Year: 2010, Jahrgang: 37, Pages: 23-29
ISSN:1573-2711
DOI:10.1007/s11249-009-9486-7
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s11249-009-9486-7
Volltext
Verfasserangaben:J.P. Kretzer, M. Krachler, J. Reinders, E. Jakubowitz, M. Thomsen, C. Heisel

MARC

LEADER 00000caa a2200000 c 4500
001 1837831637
003 DE-627
005 20240327080208.0
007 cr uuu---uuuuu
008 230301s2010 xx |||||o 00| ||eng c
024 7 |a 10.1007/s11249-009-9486-7  |2 doi 
035 |a (DE-627)1837831637 
035 |a (DE-599)KXP1837831637 
035 |a (OCoLC)1389821503 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kretzer, Jan Philippe  |d 1978-  |e VerfasserIn  |0 (DE-588)136998348  |0 (DE-627)589003690  |0 (DE-576)301383103  |4 aut 
245 1 0 |a Determination of low wear rates in metal-on-metal hip joint replacements based on ultra trace element analysis in simulator studies  |c J.P. Kretzer, M. Krachler, J. Reinders, E. Jakubowitz, M. Thomsen, C. Heisel 
264 1 |c 2010 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 21 Juli 2009 
500 |a Gesehen am 01.03.2023 
520 |a Metal-on-metal joint bearings are being increasingly used for total hip arthroplasty. Previous results from simulator tests to determine wear of metal-on-metal bearings exhibited high fluctuations. Consequently, wear tests had to be performed for a long period of time to achieve stable values. The aim of this study was to establish a method for the precise measurement of wear of metal-on-metal bearings. Wear was determined by analyzing the concentrations of particles and selected elements in the test medium (serum) using high resolution-inductively coupled plasma-mass spectrometry (HR-ICP-MS). The procedure was first validated and compared to gravimetric measurements on two different implant designs and then applied in wear tests on four total hip resurfacing implants. The validation showed a significant reliability of the HR-ICP-MS method (p ≤ 0.02). The final wear test revealed that the HR-ICP-MS method can precisely detect very low wear rates and accurately characterize alterations in wear progression. The duration of simulation can be reduced due to the high detection power and low fluctuation in HR-ICP-MS wear determination analyses. This approach is suitable for test implants with extremely low wear rates. 
650 4 |a Biotribology 
650 4 |a Chemical analytical techniques 
650 4 |a Human joints 
650 4 |a Replacements 
650 4 |a Wear/failure testing devices 
700 1 |a Krachler, Michael  |e VerfasserIn  |0 (DE-588)1058424734  |0 (DE-627)796871841  |0 (DE-576)414607627  |4 aut 
700 1 |a Reinders, Jörn  |d 1982-  |e VerfasserIn  |0 (DE-588)1068844167  |0 (DE-627)820817708  |0 (DE-576)428211445  |4 aut 
700 1 |a Jakubowitz, Eike  |d 1973-  |e VerfasserIn  |0 (DE-588)137928424  |0 (DE-627)696194007  |0 (DE-576)305131516  |4 aut 
700 1 |a Thomsen, Marc N.  |e VerfasserIn  |0 (DE-588)1063682932  |0 (DE-627)812452437  |0 (DE-576)422828025  |4 aut 
700 1 |a Heisel, Jens Christian  |d 1970-  |e VerfasserIn  |0 (DE-588)121649334  |0 (DE-627)705601307  |0 (DE-576)292815204  |4 aut 
773 0 8 |i Enthalten in  |t Tribology letters  |d Cham : Springer International Publishing, 1995  |g 37(2010), Seite 23-29  |h Online-Ressource  |w (DE-627)319335984  |w (DE-600)2015908-0  |w (DE-576)121191494  |x 1573-2711  |7 nnas  |a Determination of low wear rates in metal-on-metal hip joint replacements based on ultra trace element analysis in simulator studies 
773 1 8 |g volume:37  |g year:2010  |g pages:23-29  |g extent:7  |a Determination of low wear rates in metal-on-metal hip joint replacements based on ultra trace element analysis in simulator studies 
856 4 0 |u https://doi.org/10.1007/s11249-009-9486-7  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230301 
993 |a Article 
994 |a 2010 
998 |g 121649334  |a Heisel, Jens Christian  |m 121649334:Heisel, Jens Christian  |d 50000  |e 50000PH121649334  |k 0/50000/  |p 6 
998 |g 1063682932  |a Thomsen, Marc N.  |m 1063682932:Thomsen, Marc N.  |d 50000  |e 50000PT1063682932  |k 0/50000/  |p 5  |y j 
998 |g 137928424  |a Jakubowitz, Eike  |m 137928424:Jakubowitz, Eike  |d 910000  |d 911460  |e 910000PJ137928424  |e 911460PJ137928424  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 1068844167  |a Reinders, Jörn  |m 1068844167:Reinders, Jörn  |d 50000  |e 50000PR1068844167  |k 0/50000/  |p 3 
998 |g 1058424734  |a Krachler, Michael  |m 1058424734:Krachler, Michael  |p 2 
998 |g 136998348  |a Kretzer, Jan Philippe  |m 136998348:Kretzer, Jan Philippe  |d 910000  |d 911460  |e 910000PK136998348  |e 911460PK136998348  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1837831637  |e 4282143355 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"person":[{"given":"Jan Philippe","role":"aut","display":"Kretzer, Jan Philippe","family":"Kretzer"},{"given":"Michael","role":"aut","display":"Krachler, Michael","family":"Krachler"},{"given":"Jörn","role":"aut","display":"Reinders, Jörn","family":"Reinders"},{"family":"Jakubowitz","display":"Jakubowitz, Eike","role":"aut","given":"Eike"},{"display":"Thomsen, Marc N.","family":"Thomsen","role":"aut","given":"Marc N."},{"role":"aut","given":"Jens Christian","family":"Heisel","display":"Heisel, Jens Christian"}],"id":{"doi":["10.1007/s11249-009-9486-7"],"eki":["1837831637"]},"recId":"1837831637","relHost":[{"language":["eng"],"part":{"pages":"23-29","year":"2010","text":"37(2010), Seite 23-29","extent":"7","volume":"37"},"pubHistory":["1.1995 -"],"note":["Gesehen am 27. Januar 2016"],"origin":[{"dateIssuedDisp":"1995-","publisher":"Springer International Publishing ; Springer Science Business Media B.V. ; Kluwer ; Baltzer","dateIssuedKey":"1995","publisherPlace":"Cham ; Dordrecht ; London [u.a.] ; Basel"}],"title":[{"title_sort":"Tribology letters","title":"Tribology letters"}],"disp":"Determination of low wear rates in metal-on-metal hip joint replacements based on ultra trace element analysis in simulator studiesTribology letters","type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"319335984","physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["319335984"],"zdb":["2015908-0"],"issn":["1573-2711"]}}],"name":{"displayForm":["J.P. Kretzer, M. Krachler, J. Reinders, E. Jakubowitz, M. Thomsen, C. Heisel"]},"physDesc":[{"extent":"7 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"2010","dateIssuedKey":"2010"}],"note":["Online veröffentlicht: 21 Juli 2009","Gesehen am 01.03.2023"],"title":[{"title_sort":"Determination of low wear rates in metal-on-metal hip joint replacements based on ultra trace element analysis in simulator studies","title":"Determination of low wear rates in metal-on-metal hip joint replacements based on ultra trace element analysis in simulator studies"}]} 
SRT |a KRETZERJANDETERMINAT2010