In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T

Introduction: CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. The purpose of this study was to compare CTA, contrast-enhanced MRA (CEMRA) at 1.5 T, and CEMRA at 3 T for the visualization of carotid artery stents and to define the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lettau, Michael (VerfasserIn) , Sauer, Annett (VerfasserIn) , Heiland, Sabine (VerfasserIn) , Rohde, Stefan (VerfasserIn) , Reinhardt, Julia (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Hähnel, Stefan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2010
In: Neuroradiology
Year: 2010, Jahrgang: 52, Heft: 9, Pages: 823-830
ISSN:1432-1920
DOI:10.1007/s00234-009-0625-5
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00234-009-0625-5
Volltext
Verfasserangaben:Michael Lettau, Annett Sauer, Sabine Heiland, Stefan Rohde, Julia Reinhardt, Martin Bendszus, Stefan Hähnel

MARC

LEADER 00000caa a2200000 c 4500
001 1839026561
003 DE-627
005 20230710151847.0
007 cr uuu---uuuuu
008 230313s2010 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00234-009-0625-5  |2 doi 
035 |a (DE-627)1839026561 
035 |a (DE-599)KXP1839026561 
035 |a (OCoLC)1389811900 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Lettau, Michael  |d 1964-  |e VerfasserIn  |0 (DE-588)121994279  |0 (DE-627)705729583  |0 (DE-576)293036489  |4 aut 
245 1 0 |a In vitro comparison of different carotid artery stents  |b a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T  |c Michael Lettau, Annett Sauer, Sabine Heiland, Stefan Rohde, Julia Reinhardt, Martin Bendszus, Stefan Hähnel 
264 1 |c 2010 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 19 November 2009 
500 |a Gesehen am 13.03.2023 
520 |a Introduction: CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. The purpose of this study was to compare CTA, contrast-enhanced MRA (CEMRA) at 1.5 T, and CEMRA at 3 T for the visualization of carotid artery stents and to define the best noninvasive imaging technique for each stent. Methods: CTA and CEMRA appearances of 18 carotid artery stents of different designs and sizes (4.0 to 10.0 mm) were investigated in vitro. The profile of the contrast-to-noise ratio (CNR) of the lumen of each stent was calculated semiautomatically by a pixel-by-pixel analysis using the medical imaging software OSIRIS®. For each stent, artificial lumen narrowing (ALN) was calculated. Results: In all but one stents, ALN was lower on CEMRA at 3 T than at 1.5 T. With CEMRA at 3 T and at 1.5 T, ALN in most nitinol stents was lower than in the groups of stainless steel and cobalt alloy stents. In most nitinol stents, ALN on CEMRA at 3 T was lower than on CTA. In all stainless steel stents and cobalt alloy stents, ALN was lower on CTA than on CEMRA. With CTA and CEMRA, in most stents ALN decreased with increasing stent diameter. Conclusion: CTA and CEMRA evaluation of vessel patency after stent placement is possible, but considerably impaired by ALN. Investigators should be informed about the method of choice for every stent. 
650 4 |a 3 T 
650 4 |a Carotid artery stents 
650 4 |a CTA 
650 4 |a In vitro 
650 4 |a MRA 
700 1 |a Sauer, Annett  |e VerfasserIn  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Rohde, Stefan  |e VerfasserIn  |4 aut 
700 1 |a Reinhardt, Julia  |e VerfasserIn  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Hähnel, Stefan  |d 1966-  |e VerfasserIn  |0 (DE-588)113981937  |0 (DE-627)558821138  |0 (DE-576)289781639  |4 aut 
773 0 8 |i Enthalten in  |t Neuroradiology  |d Berlin : Springer, 1970  |g 52(2010), 9, Seite 823-830  |h Online-Ressource  |w (DE-627)254638430  |w (DE-600)1462953-7  |w (DE-576)074531484  |x 1432-1920  |7 nnas  |a In vitro comparison of different carotid artery stents a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T 
773 1 8 |g volume:52  |g year:2010  |g number:9  |g pages:823-830  |g extent:8  |a In vitro comparison of different carotid artery stents a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T 
856 4 0 |u https://doi.org/10.1007/s00234-009-0625-5  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230313 
993 |a Article 
994 |a 2010 
998 |g 113981937  |a Hähnel, Stefan  |m 113981937:Hähnel, Stefan  |d 910000  |d 911100  |d 50000  |e 910000PH113981937  |e 911100PH113981937  |e 50000PH113981937  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 7  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 121994279  |a Lettau, Michael  |m 121994279:Lettau, Michael  |d 50000  |e 50000PL121994279  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1839026561  |e 4288700191 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"8 S."}],"recId":"1839026561","origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"2010"}],"relHost":[{"part":{"year":"2010","volume":"52","pages":"823-830","extent":"8","text":"52(2010), 9, Seite 823-830","issue":"9"},"title":[{"title_sort":"Neuroradiology","title":"Neuroradiology","subtitle":"a journal devoted to neuroimaging and interventional neuroradiology ; official organ of the European Society of Neuroradiology"}],"id":{"eki":["254638430"],"issn":["1432-1920"],"zdb":["1462953-7"]},"note":["Gesehen am 06.12.05","Teils ungezählte Beil.: Supplement"],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1970 -"],"origin":[{"publisher":"Springer ; Springer","publisherPlace":"Berlin ; Heidelberg ; Berlin ; Heidelberg ; New York, NY","dateIssuedKey":"1970","dateIssuedDisp":"1970-"}],"disp":"In vitro comparison of different carotid artery stents a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 TNeuroradiology","recId":"254638430","physDesc":[{"extent":"Online-Ressource"}]}],"person":[{"given":"Michael","role":"aut","family":"Lettau","display":"Lettau, Michael"},{"family":"Sauer","role":"aut","given":"Annett","display":"Sauer, Annett"},{"family":"Heiland","role":"aut","given":"Sabine","display":"Heiland, Sabine"},{"given":"Stefan","role":"aut","family":"Rohde","display":"Rohde, Stefan"},{"role":"aut","given":"Julia","family":"Reinhardt","display":"Reinhardt, Julia"},{"role":"aut","given":"Martin","family":"Bendszus","display":"Bendszus, Martin"},{"family":"Hähnel","role":"aut","given":"Stefan","display":"Hähnel, Stefan"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Online veröffentlicht: 19 November 2009","Gesehen am 13.03.2023"],"title":[{"subtitle":"a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T","title_sort":"In vitro comparison of different carotid artery stents","title":"In vitro comparison of different carotid artery stents"}],"name":{"displayForm":["Michael Lettau, Annett Sauer, Sabine Heiland, Stefan Rohde, Julia Reinhardt, Martin Bendszus, Stefan Hähnel"]},"id":{"doi":["10.1007/s00234-009-0625-5"],"eki":["1839026561"]}} 
SRT |a LETTAUMICHINVITROCOM2010