An expandable catheter loop coil for intravascular MRI in larger blood vessels

The present study proposes a catheter system with an expandable coil etched on a polyimide foil. The catheter system combines the advantages of a small insertion diameter when the coil is rolled up in a protective carrier sheath with an increased signal-to-noise ratio (SNR) and penetration depth whe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Homagk, Ann-Kathrin Verena (VerfasserIn) , Umathum, Reiner (VerfasserIn) , Korn, Matthias (VerfasserIn) , Weber, Marc-André (VerfasserIn) , Hallscheidt, Peter (VerfasserIn) , Semmler, Wolfhard (VerfasserIn) , Bock, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: [February 2010]
In: Magnetic resonance in medicine
Year: 2010, Jahrgang: 63, Heft: 2, Pages: 517-523
ISSN:1522-2594
DOI:10.1002/mrm.22228
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1002/mrm.22228
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.22228
Volltext
Verfasserangaben:Ann-Kathrin Homagk, Reiner Umathum, Matthias Korn, Marc-André Weber, Peter Hallscheidt, Wolfhard Semmler, and Michael Bock

MARC

LEADER 00000caa a2200000 c 4500
001 1839512474
003 DE-627
005 20230710150126.0
007 cr uuu---uuuuu
008 230317s2010 xx |||||o 00| ||eng c
024 7 |a 10.1002/mrm.22228  |2 doi 
035 |a (DE-627)1839512474 
035 |a (DE-599)KXP1839512474 
035 |a (OCoLC)1389807171 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Homagk, Ann-Kathrin Verena  |e VerfasserIn  |0 (DE-588)140367683  |0 (DE-627)703653121  |0 (DE-576)316614491  |4 aut 
245 1 3 |a An expandable catheter loop coil for intravascular MRI in larger blood vessels  |c Ann-Kathrin Homagk, Reiner Umathum, Matthias Korn, Marc-André Weber, Peter Hallscheidt, Wolfhard Semmler, and Michael Bock 
264 1 |c [February 2010] 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 13 November 2009 
500 |a Gesehen am 17.03.2023 
520 |a The present study proposes a catheter system with an expandable coil etched on a polyimide foil. The catheter system combines the advantages of a small insertion diameter when the coil is rolled up in a protective carrier sheath with an increased signal-to-noise ratio (SNR) and penetration depth when the coil is pushed out. After imaging, the coil can be retracted into the sheath and folded back into the initial rolled-up configuration due to the tapered geometry of the carrier foil. The catheter system was tested on two healthy anesthetized pigs, including tracking and high-resolution intravascular imaging. To reduce artifacts in high-resolution images induced by catheter motion in the pulsatile blood flow, a motion-gating method was implemented that combines a flow-compensated two-dimensional fast low angle shot (FLASH) imaging sequence with the acquisition of projection data for retrospective gating. Using the projection data for motion detection, image SNR was increased by up to 500% over uncorrected images, and anatomic structures of 150 μm size could be differentiated in the aorta. Magn Reson Med, 2010. © 2009 Wiley-Liss, Inc. 
650 4 |a catheter coil 
650 4 |a flexible RF coil 
650 4 |a interventional procedures 
650 4 |a intravascular magnetic resonance imaging 
650 4 |a motion gating 
700 1 |a Umathum, Reiner  |e VerfasserIn  |0 (DE-588)1067822143  |0 (DE-627)81922698X  |0 (DE-576)426949471  |4 aut 
700 1 |a Korn, Matthias  |e VerfasserIn  |0 (DE-588)139120971  |0 (DE-627)608601284  |0 (DE-576)310358973  |4 aut 
700 1 |a Weber, Marc-André  |d 1973-  |e VerfasserIn  |0 (DE-588)142373044  |0 (DE-627)704211432  |0 (DE-576)330376802  |4 aut 
700 1 |a Hallscheidt, Peter  |e VerfasserIn  |0 (DE-588)1072530686  |0 (DE-627)827694156  |0 (DE-576)173264670  |4 aut 
700 1 |a Semmler, Wolfhard  |d 1944-  |e VerfasserIn  |0 (DE-588)1037890477  |0 (DE-627)756409713  |0 (DE-576)391933639  |4 aut 
700 1 |a Bock, Michael  |e VerfasserIn  |0 (DE-588)1140749323  |0 (DE-627)898660335  |0 (DE-576)494021470  |4 aut 
773 0 8 |i Enthalten in  |t Magnetic resonance in medicine  |d New York, NY [u.a.] : Wiley-Liss, 1984  |g 63(2010), 2, Seite 517-523  |h Online-Ressource  |w (DE-627)303257040  |w (DE-600)1493786-4  |w (DE-576)096290455  |x 1522-2594  |7 nnas  |a An expandable catheter loop coil for intravascular MRI in larger blood vessels 
773 1 8 |g volume:63  |g year:2010  |g number:2  |g pages:517-523  |g extent:7  |a An expandable catheter loop coil for intravascular MRI in larger blood vessels 
856 4 0 |u https://doi.org/10.1002/mrm.22228  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.22228  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20230317 
993 |a Article 
994 |a 2010 
998 |g 1140749323  |a Bock, Michael  |m 1140749323:Bock, Michael  |d 50000  |e 50000PB1140749323  |k 0/50000/  |p 6 
998 |g 1072530686  |a Hallscheidt, Peter  |m 1072530686:Hallscheidt, Peter  |d 50000  |e 50000PH1072530686  |k 0/50000/  |p 5 
998 |g 142373044  |a Weber, Marc-André  |m 142373044:Weber, Marc-André  |d 910000  |d 911400  |e 910000PW142373044  |e 911400PW142373044  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1067822143  |a Umathum, Reiner  |m 1067822143:Umathum, Reiner  |d 130000  |e 130000PU1067822143  |k 0/130000/  |p 2 
998 |g 140367683  |a Homagk, Ann-Kathrin Verena  |m 140367683:Homagk, Ann-Kathrin Verena  |d 130000  |e 130000PH140367683  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN1839512474  |e 4292120099 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Ann-Kathrin Homagk, Reiner Umathum, Matthias Korn, Marc-André Weber, Peter Hallscheidt, Wolfhard Semmler, and Michael Bock"]},"id":{"doi":["10.1002/mrm.22228"],"eki":["1839512474"]},"origin":[{"dateIssuedKey":"2010","dateIssuedDisp":"[February 2010]"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1522-2594"],"zdb":["1493786-4"],"doi":["10.1002/(ISSN)1522-2594"],"eki":["303257040"]},"origin":[{"dateIssuedKey":"1984","publisher":"Wiley-Liss","dateIssuedDisp":"1984-","publisherPlace":"New York, NY [u.a.]"}],"recId":"303257040","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"An expandable catheter loop coil for intravascular MRI in larger blood vesselsMagnetic resonance in medicine","note":["Gesehen am 28.02.08"],"part":{"volume":"63","text":"63(2010), 2, Seite 517-523","extent":"7","year":"2010","pages":"517-523","issue":"2"},"titleAlt":[{"title":"MRM"}],"pubHistory":["1.1984 -"],"title":[{"title":"Magnetic resonance in medicine","subtitle":"MRM ; an official journal of the International Society for Magnetic Resonance in Medicine","title_sort":"Magnetic resonance in medicine"}]}],"physDesc":[{"extent":"7 S.","noteIll":"Illustrationen"}],"person":[{"roleDisplay":"VerfasserIn","display":"Homagk, Ann-Kathrin Verena","role":"aut","family":"Homagk","given":"Ann-Kathrin Verena"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Umathum, Reiner","given":"Reiner","family":"Umathum"},{"family":"Korn","given":"Matthias","display":"Korn, Matthias","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Weber, Marc-André","given":"Marc-André","family":"Weber"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Hallscheidt, Peter","given":"Peter","family":"Hallscheidt"},{"roleDisplay":"VerfasserIn","display":"Semmler, Wolfhard","role":"aut","family":"Semmler","given":"Wolfhard"},{"roleDisplay":"VerfasserIn","display":"Bock, Michael","role":"aut","family":"Bock","given":"Michael"}],"title":[{"title":"An expandable catheter loop coil for intravascular MRI in larger blood vessels","title_sort":"expandable catheter loop coil for intravascular MRI in larger blood vessels"}],"recId":"1839512474","language":["eng"],"note":["First published: 13 November 2009","Gesehen am 17.03.2023"],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a HOMAGKANNKEXPANDABLE2010