Comparison between second generation HydroSoft coils and bare platinum coils for the treatment of large intracranial aneurysms

BackgroundThe development of HydroSoft coils (HSC) aims to reduce the high recurrence and retreatment rates observed in large brain aneurysms by improving primary brain aneurysm filling and thus occlusion efficacy. We compared clinical and angiographic effectiveness of bare platinum coils (BPC) vers...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tessitore, Agostino (VerfasserIn) , Paolucci, Aldo (VerfasserIn) , Hohenstatt, Sophia (VerfasserIn) , Caragliano, Antonio A (VerfasserIn) , Buonomo, Orazio (VerfasserIn) , Mormina, Enricomaria (VerfasserIn) , Pitrone, Antonio (VerfasserIn) , Vinci, Sergio L (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2022
In: Interventional neuroradiology
Year: 2023, Jahrgang: 29, Heft: 3, Pages: 321-326
ISSN:2385-2011
DOI:10.1177/15910199221088711
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1177/15910199221088711
Verlag, kostenfrei, Volltext: https://journals.sagepub.com/doi/10.1177/15910199221088711
Volltext
Verfasserangaben:Agostino Tessitore, Aldo Paolucci, Sophia Hohenstatt, Antonio A Caragliano, Orazio Buonomo, Enricomaria Mormina, Antonio Pitrone and Sergio L Vinci

MARC

LEADER 00000caa a2200000 c 4500
001 1839711779
003 DE-627
005 20240626134623.0
007 cr uuu---uuuuu
008 230321s2022 xx |||||o 00| ||eng c
024 7 |a 10.1177/15910199221088711  |2 doi 
035 |a (DE-627)1839711779 
035 |a (DE-599)KXP1839711779 
035 |a (OCoLC)1389534274 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Tessitore, Agostino  |e VerfasserIn  |0 (DE-588)1284014002  |0 (DE-627)1839711183  |4 aut 
245 1 0 |a Comparison between second generation HydroSoft coils and bare platinum coils for the treatment of large intracranial aneurysms  |c Agostino Tessitore, Aldo Paolucci, Sophia Hohenstatt, Antonio A Caragliano, Orazio Buonomo, Enricomaria Mormina, Antonio Pitrone and Sergio L Vinci 
264 1 |c 2022 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.03.2023 
520 |a BackgroundThe development of HydroSoft coils (HSC) aims to reduce the high recurrence and retreatment rates observed in large brain aneurysms by improving primary brain aneurysm filling and thus occlusion efficacy. We compared clinical and angiographic effectiveness of bare platinum coils (BPC) versus second generation HSC for large intracranial aneurysms at our center.MethodsWe included 61 large aneurysms between 2015 and 2018, 29 embolized primarily using HSC and 32 treated with BPC. The aneurysm occlusion rates were assessed after 3 and 12 months with an MRI scan and at 6 moths with a control digital subtraction angiography (DSA) using the Raymond-Roy occlusion classification (RROC). Clinical outcomes were evaluated using the modified ranking scale (mRS).ResultsThe observed immediate occlusion rate was slightly better in the BPC group, however, this group had a significant increase of progressive reperfusion at all imaging follow-up. Contrarily, the rate of complete occlusion increased significantly in the HSC group, starting from the 6 and 12-months follow-up. 7 aneurysms (11.4%) were re-treated (15.6% BPC and 6.9% HSC). The 6 and 12-months clinical data showed mRS score 0-1 in 96.7% of patients.ConclusionsIn our single-center experience, the second generation HydroSoft coils were shown to be safe and effective for endovascular treatment of large intracranial aneurysms with encouraging clinical and angiographic results, also for ruptured aneurysms. Even if the validity is limited due to our small cohort size, HSC showed a significantly lower rate of recurrence at mid-term follow-up when compared to BPC. 
700 1 |a Paolucci, Aldo  |e VerfasserIn  |4 aut 
700 1 |a Hohenstatt, Sophia  |d 1994-  |e VerfasserIn  |0 (DE-588)1284014207  |0 (DE-627)1839711493  |4 aut 
700 1 |a Caragliano, Antonio A  |e VerfasserIn  |4 aut 
700 1 |a Buonomo, Orazio  |e VerfasserIn  |4 aut 
700 1 |a Mormina, Enricomaria  |e VerfasserIn  |4 aut 
700 1 |a Pitrone, Antonio  |e VerfasserIn  |4 aut 
700 1 |a Vinci, Sergio L  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Interventional neuroradiology  |d London : Sage Publishing, 1995  |g 29(2023), 3, Seite 321-326  |h Online-Ressource  |w (DE-627)634383299  |w (DE-600)2571161-1  |w (DE-576)351479112  |x 2385-2011  |7 nnas  |a Comparison between second generation HydroSoft coils and bare platinum coils for the treatment of large intracranial aneurysms 
773 1 8 |g volume:29  |g year:2023  |g number:3  |g pages:321-326  |g extent:6  |a Comparison between second generation HydroSoft coils and bare platinum coils for the treatment of large intracranial aneurysms 
856 4 0 |u https://doi.org/10.1177/15910199221088711  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://journals.sagepub.com/doi/10.1177/15910199221088711  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20230321 
993 |a Article 
994 |a 2022 
998 |g 1284014207  |a Hohenstatt, Sophia  |m 1284014207:Hohenstatt, Sophia  |d 910000  |d 911100  |e 910000PH1284014207  |e 911100PH1284014207  |k 0/910000/  |k 1/910000/911100/  |p 3 
999 |a KXP-PPN1839711779  |e 4294357509 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Agostino Tessitore, Aldo Paolucci, Sophia Hohenstatt, Antonio A Caragliano, Orazio Buonomo, Enricomaria Mormina, Antonio Pitrone and Sergio L Vinci"]},"origin":[{"dateIssuedDisp":"2022","dateIssuedKey":"2022"}],"id":{"eki":["1839711779"],"doi":["10.1177/15910199221088711"]},"physDesc":[{"extent":"6 S."}],"relHost":[{"origin":[{"dateIssuedDisp":"1995-","publisher":"Sage Publishing ; Ed. del Centauro","dateIssuedKey":"1995","publisherPlace":"London ; Milano"}],"id":{"zdb":["2571161-1"],"eki":["634383299"],"issn":["2385-2011"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Interventional neuroradiology","subtitle":"INR : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences","title_sort":"Interventional neuroradiology"}],"pubHistory":["1.1995 -"],"titleAlt":[{"title":"INR"}],"part":{"pages":"321-326","issue":"3","year":"2023","extent":"6","volume":"29","text":"29(2023), 3, Seite 321-326"},"disp":"Comparison between second generation HydroSoft coils and bare platinum coils for the treatment of large intracranial aneurysmsInterventional neuroradiology","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 20.01.2017"],"recId":"634383299","language":["eng"]}],"person":[{"given":"Agostino","family":"Tessitore","role":"aut","display":"Tessitore, Agostino","roleDisplay":"VerfasserIn"},{"family":"Paolucci","given":"Aldo","roleDisplay":"VerfasserIn","display":"Paolucci, Aldo","role":"aut"},{"given":"Sophia","family":"Hohenstatt","role":"aut","roleDisplay":"VerfasserIn","display":"Hohenstatt, Sophia"},{"role":"aut","display":"Caragliano, Antonio A","roleDisplay":"VerfasserIn","given":"Antonio A","family":"Caragliano"},{"role":"aut","display":"Buonomo, Orazio","roleDisplay":"VerfasserIn","given":"Orazio","family":"Buonomo"},{"roleDisplay":"VerfasserIn","display":"Mormina, Enricomaria","role":"aut","family":"Mormina","given":"Enricomaria"},{"display":"Pitrone, Antonio","roleDisplay":"VerfasserIn","role":"aut","family":"Pitrone","given":"Antonio"},{"role":"aut","display":"Vinci, Sergio L","roleDisplay":"VerfasserIn","given":"Sergio L","family":"Vinci"}],"title":[{"title_sort":"Comparison between second generation HydroSoft coils and bare platinum coils for the treatment of large intracranial aneurysms","title":"Comparison between second generation HydroSoft coils and bare platinum coils for the treatment of large intracranial aneurysms"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 21.03.2023"],"recId":"1839711779","language":["eng"]} 
SRT |a TESSITOREACOMPARISON2022